DOWNLOAD Sony DCR-TRV30 / DCR-TRV30E (serv.man2) Service Manual ↓ Size: 15.3 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV30 DCR-TRV30E (serv.man2)
Pages
127
Size
15.3 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-trv30-dcr-trv30e-sm2.pdf
Date

Sony DCR-TRV30 / DCR-TRV30E (serv.man2) Service Manual ▷ View online

5-15
4. E  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 7 Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F, 7 Page Data”).
Address
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F to 11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26 to 2B
2C
2D
2E to 31
32
33
34
35
36 to 54
55
56 to 85
86
87 to AE
AF
B0 to C8
C9
Remark
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-2 (*1)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
*1: Camera microprocessor version 2.0 or later only.
When copy data from other unit, confirm that the camera
microprocessor version of the unit is 2.0 or later.
Table. 5-1-7.
Address
CA to DA
DB
DC to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Address
00 to 12
13
14 to 18
19
1A to 1F
20
21
22
23 to 26
27
28 to 2A
2B
2C
2D to 30
31
32 to 33
34
35
36 to 3A
3B
3C
3D
3E
3F to 41
42
43
44
45
46
47
48 to 49
4A
4B
4C
4D
4E to 4F
50
51
52
53
54
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
5. 7  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 7 Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F, 7 Page Data”).
5-16
Address
F7
F8
F9 to FC
FD
FE
FF
Remark
Fixed data-2 (*1)
Fixed data-1
Fixed data-2 (*1)
Fixed data-2
*1: Camera microprocessor version 2.0 or later only.
When copy data from other unit, confirm that the camera
microprocessor version of the unit is 2.0 or later.
Table. 5-1-8.
Version check of the camera microprocessor:
(VC-264 board IC452)
Order Page Address Data
Procedure
1
6
FF
The data shows the version of
the camera microprocessor.
01: Ver. 1.0 (CXP973048-205GA)
02: Ver. 2.0 (CXP973048-206GA)
Address
55
56
57
58
59 to 6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D to 90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F to A1
A2
A3
A4 to BD
BE
BF to C2
C3
C4
C5 to C6
C7
C8
C9
CA
CB
CC to CF
D0
D1
D2
D3 to E2
E3
E4 to EB
EC
ED to F6
Remark
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built
in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-2 (*1)
Fixed data-1
Fixed data-2 (*1)
Fixed data-1
Fixed data-2 (*1)
Fixed data-1
Fixed data-2
Fixed data-2 (*1)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2 (*1)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
7 page
5-17
Fig. 5-1-6.
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENT” are
satisfied.
Note:
NTSC model: DCR-TRV30
PAL model: DCR-TRV30E
1. 40.5 MHz / 54 MHz Origin Oscillation Adjustment
(VC-264 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin wg of IC302
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
12
Specified Value
13500000 ± 68Hz
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
12
Change the data and set the
frequency (f) to the specified
value.
3
F
12
Press PAUSE button.
4
0
01
00
Set the data.
1
12
24
IC302
VC-264 board
13
37
48
36
25
2. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note 1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
15, 16, 17, 18, 19, 1A
Specified Value 1
15 to 19
Specified Value 2
87 to 8B
Specified Value 3
87 to 8B
Specified Value 4
15 to 19
Note 1:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
ND display data
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
94
17
Set the data.
3
6
95
89
Set the data.
4
6
01
6D
Set the data, and press PAUSE button.
5
6
02
Check that the data changes to
“01”. (Note 2)
6
6
01
00
Set the data, and press PAUSE
button.
Note 2:
The adjustment data will be automatically input to page: F, address:
15 to 1A.
Checking method:
Order Page Address Data
Procedure
1
6
04
03
Set the data.
2
6
01
01
Set the data, and press PAUSE button.
3
1
Check that the IRIS display data
(Note 1) satisfies the specified
value 1.
4
6
01
03
Set the data, and press PAUSE button.
5
1
Check that the IRIS display data
(Note 1) satisfies the specified
value.2.
6
6
01
69
Set the data, and press PAUSE button.
7
1
Check that the ND display data
(Note 1) satisfies the specified
value 3.
8
6
01
6B
Set the data, and press PAUSE button.
9
1
Check that the ND display data
(Note 1) satisfies the specified
value 4.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
94
00
Set the data.
2
6
95
00
Set the data.
3
6
01
00
Set the data, and press PAUSE button.
4
6
04
00
Set the data.
5
0
01
00
Set the data.
RadarW
RadarW
RadarW
RadarW
RadarW
5-18
3. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart
(Color reproduction adjustment
frame)(Note 1)
Adjustment Page
F
Adjustment Address
1B
Note 1:
Refer to “10. Picture Frame Setting”.
Switch setting:
1)
POWER .................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
96
00
Set the data.
3
6
97
Set the following data.
21: DCR-TRV30 (NTSC)
1A: DCR-TRV30E (PAL)
4
6
01
6F
Set the data, and press PAUSE button.
5
6
02
Check that the data changes to
“01”. (Note 2)
Note 2:
The adjustment data will be automatically input to page: F, address:
1B.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
96
00
Set the data.
2
6
97
00
Set the data.
3
6
01
00
Set the data, and press PAUSE button.
4
0
01
00
Set the data.
RadarW
RadarW
RadarW
RadarW
RadarW
Page of 127
Display

Sony DCR-TRV30 / DCR-TRV30E (serv.man2) Service Manual ▷ Download