DOWNLOAD Sony DCR-TRV30 / DCR-TRV30E (serv.man2) Service Manual ↓ Size: 15.3 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV30 DCR-TRV30E (serv.man2)
Pages
127
Size
15.3 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-trv30-dcr-trv30e-sm2.pdf
Date

Sony DCR-TRV30 / DCR-TRV30E (serv.man2) Service Manual ▷ View online

5-11
Address
D9
DA
DB to DD
DE
DF
E0 to F4
F5
F6 to FF
NTSC
Remark
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
PAL
Initial value
Table. 5-1-3.
5. 8  Page Table
Note:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the C, D, 8 Page Data”.)
Fixed data-2: Modified data.
(Refer to “2. Modification of C, D, 8 Page Data”).
Address
00 to 52
53
54 to 8F
90
91 to 98
99
9A to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 5-1-4.
D page
5-12
1-2-2.
INITIALIZATION OF B PAGE DATA
Note 1:
When reading the B page data, insert a “Memory Stick” into the
“Memory Stick” slot.
Note 2:
“INITIALIZATION OF B PAGE DATA” should be carried out
upon completion of “INITIALIZATION OF C, D, 8 PAGE DATA”.
Switch setting:
POWER ................................................................. MEMORY
1. Initializing the B Page Data
Note:
If the B page data has been initialized, the following adjustments
need to be performed again.
1) Modification of B page data
Adjusting page
B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
2
8F
02
Set the data, and press PAUSE button.
3
2
8F
03
Set the data, and press PAUSE button.
4
2
8F
02
Set the data, and press PAUSE button.
5
2
8F
00
Set the data, and press PAUSE button.
6
5
0E
00
Set the data.
7
5
01
F3
Set the data, and press PAUSE button.
8
5
00
01
Set the data, and press PAUSE button.
9
Wait for 3 sec.
10
5
0E
Check that the data is “01”.
11
5
02
01
Set the data, and press PAUSE button.
12
5
01
FE
Set the data, and press PAUSE button.
13
5
00
01
Set the data, and press PAUSE button.
14
5
02
Check that the data.
When the data is “00”, proceed
to step 19.
When the data is “FF”, proceed
to step 15.
15
2
0E
00
Set the data, and press PAUSE button.
16
5
01
FD
Set the data, and press PAUSE button.
17
5
00
01
Set the data, and press PAUSE button.
18
5
0E
Check that the data is “01”.
19
5
01
FA
Set the data, and press PAUSE button.
20
5
03
20
Set the data, and press PAUSE button.
21
5
00
01
Set the data, and press PAUSE button.
22
5
0E
Check that the data is “01”.
23
Perform “Modification of B
Page Data”.
2. Modification of B Page Data
If the B page data has been initialized, change the data of the “Fixed
data-2” address shown in the following tables by manual input.
Preparations:
Order Page Address Data
Procedure
1
2
8F
02
Set the data, and press PAUSE button.
2
2
8F
03
Set the data, and press PAUSE button.
3
2
8F
02
Set the data, and press PAUSE button.
4
2
8F
00
Set the data, and press PAUSE button.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder
may not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B Page data:
Order Page Address Data
Procedure
1
2
00
29
Set the data.
2
2
01
29
Set the data, and press PAUSE button.
3. B  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B Page Data”).
Address
00 to FF
Remark
Fixed data-1
Table. 5-1-5.
5-13
1-2-3.
INITIALIZATION OF E, F, 7 PAGE DATA
1. Initializing the E, F, 7 Page Data
Note 1:
If “Initializing the E, F, 7 Page Data” is performed, all data of the
E page, F page and 7 page will be initialized. (It is impossible to
initialize a single page.)
Note 2:
If the E, F, 7 page data has been initialized, following adjustments
need to be performed again.
1) Modification of E, F, 7 page data
2) Camera system adjustments
3) IR transmitter adjustments
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
7
Adjusting Address
00 to FB
Switch setting:
POWER ......................................................................... CAMERA
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
Set the following data, and press
PAUSE button.
2D: DCR-TRV30 (NTSC)
2F: DCR-TRV30E (PAL)
3
6
03
01
Set the data.
4
6
02
Check that the data changes to “01”.
5
Perform “Modification of E, F, 7
Page Data”.
2. Modification of E, F, 7 Page Data
If the E, F, 7 page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder
may not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 7 Page data:
1)
Select page: 0, address: 01, and set data: 00.
2)
Turn off the power and turn on again.
3. F  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 7 Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F, 7 Page Data”).
Address
00 to 0F
10 to 11
12
13 to 14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34 to 36
37
38
39 to 3A
3B
3C
3D
3E
3F
40
41
42
43
44
45
NTSC
40
81
B0
17
70
50
8D
C8
80
7A
00
00
80
80
80
80
80
80
80
80
78
3B
33
3C
96
6D
27
65
2C
2D
02
E5
84
4A
AD
47
F0
21
Remark
Fixed data-1
40.5 MHz / 54 MHz origin osc adj.
Fixed data-1
HALL adj.
MAX GAIN adj.
AWB & LV standard data input
CCD output 2ch matching adj. (2)
CCD output 2ch matching adj. (1)
(F No. & ND light quantity standard
data input)
AWB & LV standard data input
Auto white balance adj.
Strobe white balance adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Flange back adj.
PAL
40
81
B0
17
70
50
8D
E8
80
7A
00
00
80
80
80
80
80
80
80
80
78
3B
33
3C
96
6D
27
65
2C
2D
02
E5
84
4A
AD
47
F0
21
Initial value
5-14
Address
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66
67
68
69
6A
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
NTSC
80
80
40
C0
40
C0
40
C0
40
C0
8F
EF
19
00
1B
00
00
00
00
00
55
5D
70
80
80
80
80
1E
00
0C
34
09
70
07
AA
06
28
06
00
40
00
3A
00
31
00
31
00
35
30
20
00
00
00
Remark
MR adj.
Flange back adj.
Angular velocity sensor sensitivity adj.
Mechanical shutter adj.
Strobe light level adj.
Fixed data-2
IR audio deviation adj.
IR video deviation adj.
IR video carrier frequency adj.
PAL
80
80
40
C0
40
C0
40
C0
40
C0
8F
EF
19
00
1B
00
00
00
00
00
62
6C
70
80
80
80
80
1E
00
0C
34
09
70
07
AA
06
28
06
00
40
00
3A
00
31
00
31
00
35
30
20
00
00
00
Initial value
Address
7C
7D
7E to 95
96
97 to 99
9A
9B to 9E
9F
A0 to A6
A7
A8 to AB
AC
AD
AE
AF to B0
B1
B2 to C1
C2
C3
C4
C5
C6
C7 to CE
CF
D0 to D8
D9
DA to E4
E5
E6 to F1
F2
F3 to F4
F5
F6
F7
F8
F9
FA to FD
FE
FF
NTSC
00
00
Remark
CCD output 2ch matching adj. (1)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
PAL
00
00
Initial value
Table. 5-1-6.
F page
Page of 127
Display

Click on the first or last page to see other DCR-TRV30 / DCR-TRV30E (serv.man2) service manuals if exist.