DOWNLOAD Sony DCR-TRV30 / DCR-TRV30E (serv.man2) Service Manual ↓ Size: 15.3 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV30 DCR-TRV30E (serv.man2)
Pages
127
Size
15.3 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-trv30-dcr-trv30e-sm2.pdf
Date

Sony DCR-TRV30 / DCR-TRV30E (serv.man2) Service Manual ▷ View online

5-7
1-1-3.
Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform
adjustments without loading cassette.
1.
POWER switch (PS-1800 block) ........................... CAMERA
2.
NIGHT SHOT switch (Lens block) ................................. OFF
3.
DEMO MODE (Menu setting) ........................................ OFF
4.
DIGITAL ZOOM (Menu setting) .................................... OFF
5.
STEADY SHOT (Menu setting) ...................................... OFF
6.
PROGRAM AE (CF-1800 block) ................................ AUTO
7.
WHITE BALANCE (Menu setting) ............................ AUTO
8.
16 : 9 WIDE (Menu setting) ............................................ OFF
9.
PICTURE EFFECT (Menu setting) ................................. OFF
10. DISPLAY (Menu setting) .................................. V-OUT/LCD
11. DISPLAY (CK-102 board) ............................................... ON
12. FOCUS switch (CK-102 board) ............................ MANUAL
13. DIGITAL EFFECT (CK-102 board) ................................ OFF
2. Order of Adjustments
Basically carry out adjustments in the order given.
Fig.5-1-4.
3. Subjects
1)
Color bar chart (Color reproduction adjustment frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 5-1-4. (Color reproduction
adjustment frame)
2)
Clear chart (Color reproduction adjustment frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during
this time.)
3)
Flange back adjustment chart
Make the chart shown in Fig. 5-1-5 using A0 size (1189mm 
×
841mm) black and white vellum paper.
H
A=B
C=D
A B
B
C
D
A
Enlargement
V
Electronic beam scanning frame
CRT picture frame
B
A
Difference in level
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Color bar chart (Color reproduction adjustment frame )
Fig. a
(Video output terminal
output waveform)
Fig. b (TV monitor picture)
Adjust the camera zoom and direction to
obtain the output waveform shown in Fig. a
and the TV monitor display shown in Fig. b.
White
Black
841mm
1189mm
Fig. 5-1-5.
Note:
Use matte vellum paper bigger than A0, and make sure the edges of
the black and white paper joined together are not rough.
5-8
1-2.
INITIALIZATION OF B, C, D, E, F, 7, 8 PAGE
DATA
1-2-1.
INITIALIZATION OF C, D, 8 PAGE DATA
1. Initializing the C, D, 8 Page Data
Note 1:
If “Initializing the C, D, 8 Page Data” is performed, all data of the
C page, D page and 8 page will be initialized. (It is impossible to
initialize a single page.)
Note 2:
If the C, D, 8 page data has been initialized, the following
adjustments need to be performed again.
1) Modification of C, D, 8 page data
2) Serial No. input
3) Servo and RF system adjustments
4) Video system adjustments
5) Color viewfinder system adjustments
6) LCD system Adjustments
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
D
Adjusting Address
10 to FF
Adjusting page
8
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
81
Check that the data is “00”.
3
3
80
0A
Set the data, and press the
PAUSE button.
4
3
80
Check that the data changes to
“1A”
5
Perform “Modification of C, D,
8 Page Data”.
2. Modification of C, D, 8 Page Data
If the C, D, 8 page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder
may not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of C, D, 8 Page data:
Order Page Address Data
Procedure
1
2
00
29
Set the data.
2
2
01
29
Set the data, and press the
PAUSE button.
Note:
If the following symptoms occur after completing of the
“Modification of C, D, 8 page data”, check that the data of the “Fixed
data-2” addresses of D page are same as those of the same model of
the same destination.
1) The battery end mark on the LCD or viewfinder screen is flashing.
2) The power is shut off so that unit cannot operate.
3. C  Page Table
Note:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the C, D, 8 Page Data”.)
Fixed data-2: Modified data.
(Refer to “2. Modification of C, D, 8 Page Data”).
Address
00 to 0F
10
11
12
13
14 to 15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23 to 24
25
26
27
28
29
2A to 2B
2C
2D to 41
42
43
44 to 4B
4C
4D
4E to 4F
50
51
52 to 6F
70
Initial value
EE
00
00
00
E0
2A
2A
32
32
25
3E
3E
DC
99
88
E3
A1
04
20
03
Remark
Switching position adj.
Fixed data-1
Cap FG duty adj.
Fixed data-2
AEQ adj.
Fixed data-1
AEQ adj.
Fixed data-1
AGC center level adj.
PLL fo adj.
APC adj.
LPF fo adj.
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Chroma BPF fo adj.
PLL fo fine adj.
Fixed data-1
APC adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2 (Modified data. Copy the
data built in the same model.)
5-9
Address
71
72
73
74
75 to 85
86
87
88
89
8A to 9A
9B
9C
9D
9E
9F
A0
A1 to A2
A3
A4
A5
A6
A7
A8
A9 to AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9 to BF
C0
C1
C2
C3 to D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
E0 to E5
E6
E7
Initial value
Remark
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Address
E8
E9
EA
EB
EC
ED
EE
EF
F0 to F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
Initial value
08
00
46
01
02
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Remark
Serial No. input
Fixed data-1
Emergency memory address
Table. 5-1-2.
C page
5-10
4. D  Page Table
Note:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the C, D, 8 Page Data”.)
Fixed data-2: Modified data.
(Refer to “2. Modification of C, D, 8 Page Data”).
Address
00 to 0F
10
11
12
13
14
15
16
17 to 1C
1D
1E to 23
24
25
26
27
28
29
2A to 2C
2D
2E to 31
32
33 to 37
38
39 to 3F
40
41
42
43
44 to 4C
4D
4E
4F
50
51
52
53
54
55 to 57
58
59
5A
5B
5C
5D to 63
64
65
66
67
68
69 to 6A
NTSC
00
Remark
Test mode
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
PAL
00
Initial value
Address
6B
6C
6D
6E
6F
70 to 85
86
87
88
89
8A to 8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A to 9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1 to B7
B8
B9 to BB
BC
BD to BF
C0
C1
C2
C3
C4 to D0
D1
D2 to D8
NTSC
64
CA
5D
5D
AC
80
80
1D
98
98
91
2C
A1
7F
87
3F
Remark
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Backlight adj. (EVF)
VCO adj. (EVF)
Fixed data-2
RGB AMP adj. (EVF)
Fixed data-1
White balance adj.(EVF)
Contrast adj. (EVF)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
VCO adj. (LCD)
V COM adj. (LCD)
RGB AMP adj. (LCD)
Fixed data-2
V COM level adj. (LCD)
White balance adj.(LCD)
Contrast adj. (LCD)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
PAL
64
CA
7D
7D
AC
80
80
1D
98
98
91
2C
A1
7F
87
3F
Initial value
Page of 127
Display

Click on the first or last page to see other DCR-TRV30 / DCR-TRV30E (serv.man2) service manuals if exist.