DOWNLOAD Sony DCR-TRV15E / DCR-TRV17E (serv.man2) Service Manual ↓ Size: 14.7 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV15E DCR-TRV17E (serv.man2)
Pages
127
Size
14.7 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-trv15e-dcr-trv17e-sm2.pdf
Date

Sony DCR-TRV15E / DCR-TRV17E (serv.man2) Service Manual ▷ View online

5-13
1-2-3.
INITIALIZATION OF E, F, 7 PAGE DATA
1. Initializing the E, F, 7 Page Data
Note1: If “Initializing the E, F, 7 Page Data” is performed, all data
of the E page, F page and 7 page will be initialized. (It is
impossible to initialize a single page.)
Note2:
If the E, F, 7 page data has been initialized, following adjustments
need to be performed again.
1) Modification of E, F, 7 page data
2) Camera system adjustments
3) IR transmitter adjustments
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
7
Adjusting Address
00 to 5F
Switch setting:
POWER .................................................................. CAMERA
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
2F
Set the data, and press PAUSE
button.
3
6
03
01
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to “01”.
5
Perform “Modification of E, F, 7
Page Data”.
2. Modification of E, F, 7 Page Data
If the E, F, 7 page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 7 Page data
1)
Select page: 0, address: 01, and set data: 00.
2)
Turn off the power and turn on again.
3. F  Page Table
Note1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 7
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F, 7
Page Data”.)
Address
Remark
Initial value
00 to 0F
10 to 11
12
13 to 16
17
18
19
1A to 1C
1D
1E
1F
20 to 2F
30
31
32
33
34
35
36
37
38 to 3B
3C
3D
3E to 3F
40
41
42 to 49
4A
4B
4C
4D
4E
4F
50
51
52 to 59
5A
5B
5C
5D
5E
5F
60 to 65
66
67
68
69
6A to 6B
6C
6D
6E
80
81
80
17
9A
80
7A
90
3E
43
59
22
24
00
EF
80
40
51
19
22
20
93
13
00
00
46
00
19
00
2A
00
7C
74
00
80
Fixed data-1
36MHz origin osc adj.
Fixed data-1
HALL adj.
Fixed data-1
MAX GAIN adj.
AWB & LV standard data input
Fixed data-1
AWB & LV standard data input
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Auto white balance adj.
Fixed data-1
Flange back adj.
Fixed data-1
Flange back adj.
Fixed data-1
Angular velocity sensor sensitivity
adj.
Fixed data-1
Optical axis adj.
Fixed data-1
Fixed data-2
IR video carrier frequency adj.
5-14
Table. 5-1-6.
Address
Remark
Initial value
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85 to 8D
8E
8F
90 to 92
93
94
95
96
97 to A7
A8
A9 to AF
B0
B1
B2 to B3
B4
B5 to C2
C3
C4 to D4
D5
D6 to DD
DE
DF to E2
E3
E4 to FF
00
0C
34
09
70
07
AA
06
28
06
00
40
00
3A
00
31
00
31
00
35
1E
Fixed data-1
Mechanical shutter adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
00 to 50
51
52 to 69
6A
6B to 71
72
73 to 7E
7F
80 to 83
84
85
86
87
88 to 8B
8C
8D to 8E
8F
90
91
92 to 94
95
96 to 97
98
99 to AF
B0
B1
B2
B3
B4
B5
B6 to BA
BB
BC to CF
D0
D1 to DD
DE
DF to FB
FC
FD to FF
24
71
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Optical axis adj.
Fixed data-1
Optical axis adj.
Fixed data-1
Fixed data-2
Fixed data-1
4. E  Page Table
Note1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 7
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F, 7
Page Data”.)
Table. 5-1-7.
F page
5-15
5. 7  Page Table
Note1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F, 7
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F, 7
Page Data”.)
Table. 5-1-8.
Address
Remark
Initial value
00 to 1B
1C
1D
1E
1F
20
21 to 22
23
24
25
26
27 to 3C
3D
3E to 5F
80
80
80
80
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Mechanical shutter adj.
Fixed data-1
Fixed data-2
Fixed data-1
5-16
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENT” are
satisfied.
1. 36MHz Origin Oscillation Adjustment
(VC-260 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color will
become inconsistent.
Subject
Not required
Measurement Point
Pin qh of IC303
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
12
Specified Value
f=18000000 ± 90Hz
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
F
12
Change the data and set the
frequency (f) to the specified
value.
3
F
12
Press PAUSE button.
4
0
01
00
Set the data.
2. HALL Adjustment
For detecting the position of the lens iris, adjust AMP gain and
offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
17, 18, 19
Specified Value 1
14 to 18
Specified Value 2
85 to 89
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
Switch setting:
POWER .................................................................. CAMERA
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
94
16
Set the data.
3
6
95
87
Set the data.
4
6
01
6D
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to “01”.
(Note2)
6
6
01
00
Set the data, and press PAUSE
button.
Note2:
The adjustment data will be automatically input to page: F, address:
17, 18, 19.
Checking method:
Order Page Address Data
Procedure
1
6
04
03
Set the data.
2
6
01
01
Set the data, and press PAUSE
button.
3
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
4
6
01
03
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
94
00
Set the data.
2
6
95
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
6
04
00
Set the data.
5
0
01
00
Set the data.
IC303
1
12
36
25
24
13
37
48
VC-260 board
Fig. 5-1-6.
RadarW
RadarW
RadarW
Page of 127