DOWNLOAD Sony DCR-TRV15E / DCR-TRV17E (serv.man2) Service Manual ↓ Size: 14.7 MB | Pages: 127 in PDF or view online for FREE

Model
DCR-TRV15E DCR-TRV17E (serv.man2)
Pages
127
Size
14.7 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-trv15e-dcr-trv17e-sm2.pdf
Date

Sony DCR-TRV15E / DCR-TRV17E (serv.man2) Service Manual ▷ View online

5-9
Table. 5-1-2.
Address
Remark
Initial value
Address
Remark
Initial value
73
74
75 to 83
84
85
86
87
88
89
90 to 9A
9B
9C
9D
9E
9F
A0
A1 to A2
A3
A4
A5
A6
A7
A8
A9 to AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB to C1
C2
C3
C4
C5 to C6
C7
C8 to D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
E0 to E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0 to F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
08
00
46
01
02
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-2
(Modified data. Copy the data built in
the same model.)
 Fixed data-1
Fixed data-2
Fixed data-1
Serial No. input
Fixed data-1
Emergency memory address
C page
5-10
4. D  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, D, 8
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, D, 8
Page Data”.)
Address
Remark
Initial value
5C
6D to 63
64
65
66
67
68
69 to 6A
6B
6C
6D
6E
6F
70 to 8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2 to B7
B8
B9 to BB
BC
BD to D0
D1
62
BA
80
70
AD
7E
80
2D
80
70
80
30
C0
80
80
50
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Backlight adj. (EVF)
VCO adj. (EVF)
Fixed data-2
RGB AMP adj. (EVF)
Fixed data-1
White balance adj.(EVF)
Contrast adj. (EVF)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
VCO adj. (LCD)
V COM adj. (LCD)
RGB AMP adj. (LCD)
Fixed data-2
V COM level adj. (LCD)
White balance adj.(LCD)
Contrast adj. (LCD)
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Address
Remark
Initial value
00 to 0F
10
11
12
13
14
15 to 1C
1D
1E
1F to 21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34 to 37
38
39
3A
3B to 3F
40
41
42
43
44 to 4C
4D
4E
4F
50
51
52
53
54
55 to 57
58
59
5A
5B
00
Test mode
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
5-11
5. 8  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the C, D, 8
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of C, D, 8
Page Data”.)
Table. 5-1-4.
Address
Remark
00 to 52
53
54 to 8F
90
91 to 98
99
9A to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
D2 to D5
D6
D7
D8
D9
DA
DB
DC to DD
DE
DF
E0 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data built in
the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Table. 5-1-3.
D page
5-12
1-2-2.
INITIALIZATION OF B PAGE DATA
(DCR-TRV17E)
Note1:
When reading the B page data, insert a “Memory Stick” into the
“Memory Stick” slot.
Note2:
“INITIALIZATION OF B PAGE DATA” should be carried out
upon completion of “INITIALIZATION OF C, D, 8 PAGE DATA”.
Switch setting:
POWER ................................................................. MEMORY
1. Initializing the B Page Data
Note: If  the B page data has been initialized, the following
adjustments need to be performed again.
1) Modification of B page data
Adjusting page
B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
2
8F
02
Set the data, and press PAUSE
button.
3
2
8F
03
Set the data, and press PAUSE
button.
4
2
8F
02
Set the data, and press PAUSE
button.
5
2
8F
00
Set the data, and press PAUSE
button.
6
5
0E
00
Set the data.
7
5
01
F3
Set the data, and press PAUSE
button.
8
5
00
01
Set the data, and press PAUSE
button.
9
5
0E
Check that the data changes to “01”.
10
Perform “Modification of B Page
Data”.
2. Modification of B Page Data
If the B page data has been initialized, change the data of the “Fixed
data-2” address shown in the following tables by manual input.
Preparations:
Order Page Address Data
Procedure
1
2
8F
02
Set the data, and press PAUSE
button.
2
2
8F
03
Set the data, and press PAUSE
button.
3
2
8F
02
Set the data, and press PAUSE
button.
4
2
8F
00
Set the data, and press PAUSE
button.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, don’t press the PAUSE
button.
Processing after Completing Modification of B Page data:
Order Page Address Data
Procedure
1
5
0E
00
Set the data, and press PAUSE
button.
2
5
01
FB
Set the data, and press PAUSE
button.
3
5
00
01
Set the data, and press PAUSE
button.
4
5
0E
Check that the data changes to “01”.
(The change data are written in the
flash memory.)
5
2
00
29
Set the data.
6
2
01
29
Set the data, and press PAUSE
button.
3. B  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B Page
Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B Page
Data”.)
Table. 5-1-5.
Address
Remark
00 to B4
B5
B6 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Page of 127
Display

Click on the first or last page to see other DCR-TRV15E / DCR-TRV17E (serv.man2) service manuals if exist.