6-23
DCR-TRV12E/TRV14E/TRV19/TRV19E
11. Auto White Balance Standard Data Input
Adjust the white balance reference at 3200K.
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
1A to 1D
Note1:
This adjustment should be carried out upon completion of “Flange
back adjustment”,  “Optical Axis Adjustment” and “Color
reproduction adjustment”.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER ................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu setting) .................................... OFF
4)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
02
Set the data.
3
6
01
11
Set the data, and press PAUSE
button.
4
6
01
0B
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: F, address:
1A to 1D.
Processing after Completing 
Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
48
00
Set the data.
3
0
01
00
Set the data.
4
Perform  “Auto White Balance
Adjustment”.
6-24
DCR-TRV12E/TRV14E/TRV19/TRV19E
12. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
Measurement Point
Display data of page 1 (Note5)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1E to 21
Specified Value
R ratio: 2AB0 to 2B30 (NTSC)
2AA8 to 2B28 (PAL)
B ratio: 56F0 to 5770 (NTSC)
56A0 to 5720 (PAL)
Note1:
This adjustment should be carried out upon completion of “Auto
White Balance & LV Standard Data Input”.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Note5:
NTSC model: DCR-TRV19
PAL model: DCR-TRV12E/TRV14E/TRV19E
Switch setting:
1)
POWER ................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu setting) .................................... OFF
4)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the lens.
2
0
01
01
Set the data.
3
6
48
02
Set the data.
4
F
2E
Write down the data.
5
F
2E
2A
Set the data, and press PAUSE
button.
6
F
2F
Write down the data.
7
F
2F
Set the following data, and press
PAUSE button.
F0 (NTSC), E8 (PAL)
8
F
30
Write down the data.
9
F
30
Set the following data, and press
PAUSE button.
57 (NTSC), 56 (PAL)
10
F
31
Write down the data.
11
F
31
Set the following data, and press
PAUSE button.
30 (NTSC), E0 (PAL)
12
6
01
83
Set the data, and press PAUSE
button.
13
6
01
81
Set the data, and press PAUSE
button.
14
6
02
Check that the data changes to
“01”. (Note6)
15
6
01
3F
Set the data, and press PAUSE
button.
16
0
03
04
Set the data.
17
1
Check that the display data
(Note4) satisfies the R ratio
specified value.
18
0
03
05
Set the data.
19
1
Check that the display data
(Note4) satisfies the B ratio
specified value.
Note6:
The adjustment data will be automatically input to page: F, address:
1E to 21.
Processing after Completing 
Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
48
00
Set the data.
3
F
2E
Set the data that is written down
at step 4, and press PAUSE button.
4
F
2F
Set the data that is written down
at step 6, and press PAUSE button.
5
F
30
Set the data that is written down
at step 8, and press PAUSE button.
6
F
31
Set the data that is written down
at step 10, and press PAUSE
button.
7
0
03
00
Set the data.
8
0
01
00
Set the data.
6-25
DCR-TRV12E/TRV14E/TRV19/TRV19E
13. White Balance Check
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.4 and 0.1
Measurement Point
Video terminal of AUDIO/VIDEO jack
Measuring Instrument
Vectorscope
Specified Value
Fig. 6-1-14. A to B
Note1:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
POWER ................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu setting) .................................... OFF
4)
STEADY SHOT (Menu setting) ...................................... OFF
Checking method:
Order Page Address Data
Procedure
Indoor white balance check
1
Check that the lens is not covered
with either filter.
2
6
48
02
Set the data.
3
6
01
0F
Set the data, and press PAUSE
button.
4
Check that the center of the white
luminance point is within the
circle shown Fig. 6-1-14. A.
5
6
01
00
Set the data, and press PAUSE
button.
Outdoor white balance check
6
Place the C14 filter on the lens.
7
6
01
3F
Set the data, and press PAUSE
button.
8
Check that the center of the white
luminance point is within the
circle shown Fig. 6-1-14. B.
9
Remove the C14 filter.
LV data check
10
Place the ND filter 1.5
(1.0+0.1+0.4) on the lens.
11
6
01
00
Set the data, and press PAUSE
button.
12
0
03
06
Set the data.
13
1
Check that the display data (Note2)
satisfies the specified value.
Specified value: 8000 to 8BC0
Note2:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Processing after Completing 
Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
48
00
Set the data.
3
0
03
00
Set the data.
R-Y
2mm
B-Y
2mm
R-Y
B-Y
0.5mm
1mm
3mm
3mm
Fig. 6-1-14 (A).
Fig. 6-1-14 (B).
6-26
DCR-TRV12E/TRV14E/TRV19/TRV19E
14. Steady Shot Check
Precautions on the Parts Replacement
There are two types of repair parts.
Type A: ENC03MA
Type B: ENC03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Specified Value
2B00 to 4B00
Note1:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
STEADY SHOT (Menu setting) ....................................... ON
2)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
Pitch sensor check
(MA-421 board SE5402)
1
0
03
11
Set the data.
2
1
Check that the display data
(Note1) satisfies the specified
value. (Note3)
Yaw sensor check
(MA-421 board SE5401)
3
0
03
12
Set the data.
4
1
Check that the display data
(Note1) satisfies the specified
value. (Note3)
5
0
03
00
Set the data.
6
Move the camcorder, and check
that the steady shot operations
have been performed normally
Note3:
Don’t move the camcoder.
Page of 59
Display

Click on the first or last page to see other DCR-TRV12E / DCR-TRV14E / DCR-TRV19 / DCR-TRV19E (serv.man4) service manuals if exist.