DOWNLOAD Sony DCR-TRV12E / DCR-TRV14E / DCR-TRV19 / DCR-TRV19E (serv.man4) Service Manual ↓ Size: 1.26 MB | Pages: 59 in PDF or view online for FREE

Model
DCR-TRV12E DCR-TRV14E DCR-TRV19 DCR-TRV19E (serv.man4)
Pages
59
Size
1.26 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv12e-dcr-trv14e-dcr-trv19-dcr-trv19e-sm4.pdf
Date

Sony DCR-TRV12E / DCR-TRV14E / DCR-TRV19 / DCR-TRV19E (serv.man4) Service Manual ▷ View online

6-7
DCR-TRV12E/TRV14E/TRV19/TRV19E
White
Black
841mm
1189mm
1-1-3.
Precaution
1. Setting the Switch
Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette.
1.
POWER switch (FK-CX4000 block) ..................... CAMERA
2.
NIGHT SHOT switch (Lens block) ................................. OFF
3.
BACK LIGHT switch (CF-CX4000 block) ..................... OFF
4.
FUNCTION settings (Touch panel)
FOCUS (Page1) ................................................ MANUAL
SPOT METER (Page1) ............................................ AUTO
MANUAL SET of the MENU settings (Page1)
PROGRAM AE .................................................... AUTO
PICTURE EFFECT .................................................. OFF
WHITE BALANCE ............................................. AUTO
CAMERA SET of the MENU settings (Page1)
DIGITAL ZOOM ..................................................... OFF
16:9 WIDE ................................................................ OFF
STEADY SHOT ....................................................... OFF
SETUP MENU of the MENU settings (Page1)
DEMO MODE ......................................................... OFF
EXPOSURE (Page1) ................................................ AUTO
2. Order of Adjustments
Basically carry out adjustments in the order given.
Fig. 6-1-4.
3. Subjects
1)
Color bar chart (Color reproduction adjustment frame)
When performing adjustments using the color bar chart, adjust
the picture frame as shown in Fig. 6-1-4. (Color reproduction
adjustment frame)
2)
Clear chart (Color reproduction adjustment frame)
Remove the color bar chart from the pattern box and insert a
clear chart in its place. (Do not perform zoom operations during
this time.)
3)
Flange back adjustment chart
Make the chart shown in Fig. 6-1-5 using A0 size (1189mm 
×
841mm) black and white vellum paper.
H
A=B
C=D
A B
B
C
D
A
Enlargement
V
Electronic beam scanning frame
CRT picture frame
B
A
Difference in level
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Color bar chart (Color reproduction adjustment frame )
Fig. a
(Video output terminal
output waveform)
Fig. b (TV monitor picture)
Adjust the camera zoom and direction to
obtain the output waveform shown in Fig. a
and the TV monitor display shown in Fig. b.
Fig. 6-1-5.
Note:
Use matte vellum paper bigger than A0, and make sure the edges of
the black and white paper joined together are not rough.
6-8
DCR-TRV12E/TRV14E/TRV19/TRV19E
1-2.
INITIALIZATION OF 8, A, C, D, E, F, 1C
PAGE DATA
Note:
When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
[Connection of the power supply during the initialization
of the data.]
1)
Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 6-1-6.
2)
Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 6.0 ± 0.1Vdc.
3)
Turn off the power supply.
4)
Turn on the HOLD switch of the adjusting remote commander.
5)
Turn on the power supply.
6)
Perform the initialization of the data.
Note:
This is normal though the following message is indicated on the
LCD screen.
“FOR InfoLITHIUM BATTERY ONLY”
[Initialization Procedure]
1.
Initialization of A, D page data
2.
Initialization of 8, C, 1C page data
3.
Initialization of E, F page data
fig. 6-1-6
Regulated power supply
Battery terminal
Digital volt meter
COVER
COVER
6-9
DCR-TRV12E/TRV14E/TRV19/TRV19E
1-2-1.
INITIALIZATION OF A, D PAGE DATA
Note:
The data of page: 0, address: 10 must be “00”.
1. Initializing the A, D Page Data
Note1:
If “Initializing the A, D Page Data” is performed, all data of the A
page and D page will be initialized. (It is impossible to initialize a
single page.)
Note2:
If the A, D page data has been initialized, the following adjustments
need to be performed again.
1) Modification of A, D page data
2) Touch panel adjustment
Note3:
The power supply voltage must be 6.0 ± 0.1Vdc.
Note4:
NTSC model: DCR-TRV19
PAL model: DCR-TRV12E/TRV14E/TRV19E
Adjusting page
A
Adjusting Address
10 to 90
Adjusting page
D
Adjusting Address
10 to 6F
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
03
Set the following data.
01 (NTSC), 81 (PAL)
4
7
00
Set the following data.
20 (Initializing A page)
22 (Initializing D page)
28 (Initializing A and D pages)
5
7
01
Set the following data, and press
PAUSE button.
20 (Initializing A page)
22 (Initializing D page)
28 (Initializing A and D pages)
6
7
02
Check that the data changes to “01”
7
Perform “Modification of A, D
Page Data”.
2. Modification of A, D Page Data
If the A, D page data has been initialized, change the data of the
“Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modif
ication of A, D Page data
Order Page Address Data
Procedure
1
2
00
29
Set the data.
2
2
01
29
Set the data, and press PAUSE
button.
Note:
If the following symptoms occur after completing of the
“Modification of A, D page data”, check that the data of the “Fixed
data-2” addresses of A and D page are same as those of the same
model of the same destination.
1) The self-diagnosis code “E:20:00” on the LCD screen is displayed.
2) The power is shut off so that unit cannot operate.
3. A Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”).
Table. 6-1-2.
4. D Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the A, D
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, D
Page Data”).
Address
Remark
Initial value
Initial value
NTSC PAL
00 to 0F
10 to 29
2A
2B to 2C
2D
2E to 81
82
83
84
85
86 to 90
DA
27
E1
1C
DB
25
DA
23
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Touch panel adj.
Fixed data-1
Table. 6-1-3.
Address
Remark
Initial value
Address
Remark
Initial value
00 to 0F
10
11
12
13 to 57
58
59 to 6E
6F
00
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
6-10
DCR-TRV12E/TRV14E/TRV19/TRV19E
1-2-2.
INITIALIZATION OF 8, C, 1C PAGE DATA
Note:
When reading or writing the 8, C page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the 8, C, 1C Page Data
Note1:
If “Initializing the 8, C, 1C Page Data” is performed, all data of
the 8 page, C page and 1C page will be initialized. (It is impossible
to initialize a single page.)
Note2:
If the 8, C, 1C page data has been initialized, following adjustments
need to be performed again.
1) Modification of 8, C, 1C page data
2) Viewfinder system adjustments
3) LCD system adjustments
4) Serial No. input
5) Servo and RF system adjustments
6) Video system adjustments
Note3:
The power supply voltage must be 6.0 ± 0.1Vdc.
Adjusting page
8
Adjusting Address
00 to FF
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
1C
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
Check that the data is “00”.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to
“1C”.
6
Perform “Modification of 8, C,
1C Page Data”.
2. Modification of 8, C, 1C Page Data
If the 8, C, 1C page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the 8, C page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1C page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1C page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modif
ication of 8, C, 1C Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
Page of 59
Display