DOWNLOAD Sony DCR-TRV12E / DCR-TRV14E / DCR-TRV19 / DCR-TRV19E (serv.man4) Service Manual ↓ Size: 1.26 MB | Pages: 59 in PDF or view online for FREE

Model
DCR-TRV12E DCR-TRV14E DCR-TRV19 DCR-TRV19E (serv.man4)
Pages
59
Size
1.26 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-trv12e-dcr-trv14e-dcr-trv19-dcr-trv19e-sm4.pdf
Date

Sony DCR-TRV12E / DCR-TRV14E / DCR-TRV19 / DCR-TRV19E (serv.man4) Service Manual ▷ View online

6-11
DCR-TRV12E/TRV14E/TRV19/TRV19E
3. 8 Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
1C Page Data”).
Table. 6-1-4.
4. C Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
1C Page Data”).
Address
Remark
00 to 33
34
35 to 4E
4F
50 to 79
7A
7B
7C
7D to 91
92
93 to AB
AC
AD to AF
B0
B1
B2 to B4
B5
B6 to B7
B8
B9
BA
BB
BC to CB
CC
CD to D5
D6
D7
D8 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2 (Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2 (Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
Address
Remark
Initial value
00 to 0F
10
11
12
13
14 to 15
16
17 to 24
25
26
27
28 to 33
34
35
36
37
38
39
3A to 3D
3E
3F
40
41 to 44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51 to 52
53
54
55 to 57
58
59 to 60
61
62
63
64
65 to A6
A7
A8
A9
EE
00
00
00
E0
88
E3
A1
70
6F
97
37
70
70
20
9F
06
41
80
80
24
55
Switching position adj.
Fixed data-1
CAP FG duty adj.
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out Cr level adj.
S VIDEO out Cb level adj.
Fixed data-1
Fixed data-2
VCO adj. (EVF)
Fixed data-1
RGB AMP adj. (EVF)
Fixed data-1
Contrast adj. (EVF)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
VCO adj. (LCD)
V COM adj. (LCD)
RGB AMP adj. (LCD)
Black limit adj. (LCD)
PSIG GRAY adj. (LCD)
White balance adj. (LCD)
Contrast adj. (LCD)
Center level adj. (LCD)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
6-12
DCR-TRV12E/TRV14E/TRV19/TRV19E
Table. 6-1-5.
5. 1C Page Table
Note1:
When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
1C Page Data”).
Table. 6-1-6.
Address
Remark
Initial value
Address
Remark
Initial value
AA
AB
AC
AD to AF
B0
B1
B2
B3
B4
B5
B6 to CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
D6 to DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8 to F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
08
00
46
01
02
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Serial No. input
Fixed data-1
Emergency memory address
Address
Remark
Initial value
Address
Remark
Initial value
00 to A1
A2
A3
A4
A5
A6 to B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9 to FF
00
00
00
00
00
80
00
00
00
00
00
00
00
00
00
00
80
00
00
00
00
00
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Error rate check
Fixed data-1
6-13
DCR-TRV12E/TRV14E/TRV19/TRV19E
1-2-3.
INITIALIZATION OF E, F PAGE DATA
Note:
The data of page: 0, address: 10 must be “00”.
1. Initializing the E, F Page Data
Note1:
If “Initializing the E, F Page Data” is performed, all data of the E
page and F page will be initialized. (It is impossible to initialize a
single page.)
Note2:
If the E, F page data has been initialized, following adjustments
need to be performed again.
1) Modification of E, F page data
2) Camera system adjustments
Note3:
The power supply voltage must be 6.0 ± 0.1Vdc.
Note4:
NTSC model: DCR-TRV19
PAL model: DCR- TRV12E/TRV14E/TRV19E
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
10 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
Set the following data, and press
PAUSE button.
2D (NTSC), 2F (PAL)
4
6
03
FF
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”.
6
Perform “Modification of E, F
Page Data”.
2. Modification of E, F Page Data
If the E, F page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modif
ication of E, F Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
4
Perform “36MHz Origin Osc.
Adjustment” of the camera
system adjustment.
3. E Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F
Page Data”).
Address
Remark
00 to 0C
0D
0E to 0F
10
11 to 54
55
56 to 74
75
76
77
78
79 to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-7.
6-14
DCR-TRV12E/TRV14E/TRV19/TRV19E
4. F Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F
Page Data”.)
Table. 6-1-8.
Address
Remark
Initial value
Initial value
NTSC PAL
00 to 0F
10
11 to 12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26 to 29
2A
2B
2C to 31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
40
41
42
43 to 45
46
47 to ED
EE
EF
80
81
5D
8B
9A
80
7A
1B
00
07
00
0E
00
0D
00
22
27
00
F1
19
51
20
22
13
93
00
00
00
00
46
19
00
2A
00
00
00
FF
80
81
5D
8B
9A
80
7A
1B
00
07
00
0E
00
0D
00
22
24
00
EF
19
51
20
22
13
93
00
00
00
00
46
19
00
2A
00
00
00
FF
36MHz origin osc. adj.
Fixed data-1
HALL adj.
Fixed data-1
MAX GAIN adj.
LV standard data input
AWB standard data input
Auto white balance adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Flange back adj.
Fixed data-1
Optical axis adj.
Fixed data-1
Fixed data-2
Address
Remark
Initial value
Initial value
NTSC PAL
F0 to FF
Page of 59
Display

Click on the first or last page to see other DCR-TRV12E / DCR-TRV14E / DCR-TRV19 / DCR-TRV19E (serv.man4) service manuals if exist.