DOWNLOAD Sony DCR-SX30E / DCR-SX31E / DCR-SX40 / DCR-SX40E / DCR-SX41 / DCR-SX41E / DCR-SX50E / DCR-SX60 / DCR-SX60E (serv.man2) Service Manual ↓ Size: 3.7 MB | Pages: 74 in PDF or view online for FREE

Model
DCR-SX30E DCR-SX31E DCR-SX40 DCR-SX40E DCR-SX41 DCR-SX41E DCR-SX50E DCR-SX60 DCR-SX60E (serv.man2)
Pages
74
Size
3.7 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / LEVEL 2
File
dcr-sx30e-dcr-sx31e-dcr-sx40-dcr-sx40e-dcr-sx41-dc.pdf
Date

Sony DCR-SX30E / DCR-SX31E / DCR-SX40 / DCR-SX40E / DCR-SX41 / DCR-SX41E / DCR-SX50E / DCR-SX60 / DCR-SX60E (serv.man2) Service Manual ▷ View online

1-2
ENGLISH
JAPANESE
ENGLISH
JAPANESE
DCR-SX30E/SX31E/SX40/SX40E/SX41/SX41E/SX50E/SX60/SX60E_L2
1-5. SELF-DIAGNOSIS  FUNCTION
1-5-1. Self-diagnosis Function
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the LCD screen what to
do.
Details of the self-diagnosis functions are provided in the Instruction
manual.
1-5-2. Self-diagnosis Display
When problems occur while the unit is operating, the counter of the
LCD screen shows a 4-digit display consisting of an alphabet and
numbers, which blinks at 3.2 Hz. This 5-character display indicates
the “repaired by:”, “block” in which the problem occurred, and
“detailed code” of the problem.
1 1
3 1
C
Repaired by:
Refer to “1-5-3. Self-diagnosis Code Table”.
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2 Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
LCD screen
C : 3 1 : 1 1
1-5-3. Self-diagnosis Code Table
C
C
C
E
E
E
E
E
E
E
Block
Function
0
4
1
3
1
3
2
0
3
1
6
1
6
1
6
1
9
4
9
4
Detailed
Code
0
0
0
1
0
2
0
0
0
0
0
0
1
0
1
1
0
0
0
1
Symptom/State
Non-standard battery is used.
“Memory Stick Duo” is not formatted
correctly.
“Memory Stick Duo” is damaged.
Access error
Flash memory data are rewritten.
Drive fault
 
Difficult to adjust focus
(Cannot initialize focus.)
Zoom operations fault
(Cannot initialize zoom lens.)
The abnormalities in initialization of
the focus lens and the abnormalities in
initialization of the zoom lens occurred
simultaneously.
Fault of writing or erasing the flash
memory
Internal memory fault
Self-diagnosis Code
Repaired b
y:
Correction
Use the InfoLITHIUM battery.
Format the “Memory Stick Duo”.
Insert a new “Memory Stick Duo”.
Remove the power source.
Reconnect it again and operate your camcorder again.
Make flash memory data correct value. (Note 1)
Inspect or replacement of the internal memory (IC8701 on the
VC-560 board). (Note 2)
Inspect the lens block focus reset sensor (pin 8 of CN5401 on
the VC-560 board) when focusing is performed when the focus
buttons of the touch panel are pressed in the focus manual mode,
and the focus motor driver circuit (IC5401 on the VC-560 board)
when focusing is not performed.
Inspect the lens block zoom reset sensor (pin q; of CN5401 on
the VC-560 board) when zooming is performed when the zoom
lever is operated, and the zoom motor drive circuit (IC5401 on
the VC-560 board) when zooming is not performed.
Check whether the flexible board of the lens is broken, and
check whether it is inserted imperfectly. If there is no problem in
the flexible board, inspect the focus/zoom motor drive circuit
(IC5401 on the VC-560 board).
Inspect the flash memory (IC7801 on the VC-560 board).
Format the internal memory (IC8701 on the VC-560 board).
Inspect or replacement of the internal memory (IC8701 on the
VC-560 board). (Note 2)
Note 1:
 Start the Adjust Manual in the Adjust Station and refer to the “DESTINATON DATA WRITE”.
Note 2:
 Start the Adjust Manual in the Adjust Station and refer to the “INTERNAL MEMORY ADJUSTMENTS”.
1-3
ENGLISH
JAPANESE
ENGLISH
JAPANESE
DCR-SX30E/SX31E/SX40/SX40E/SX41/SX41E/SX50E/SX60/SX60E_L2
1-6-1. Laser Printed Unit
The model display adopts the laser printing method.
Therefore, the Bottom Cabinet for replacement differs depending
on the destination.
As similar displays are provided, choose the suitable one for order.
Note:
After replacing the Bottom Cabinet, the serial number for it
will be changed to the one exclusive for service use.
Inform a customer of the serial number change and change
the serial number in the repair data.
1-6. PRECAUTION  ON  REPLACING  THE  BOTTOM  CABINET
[Repair Operation]
This unit has two kinds of Bottom Cabinet.
1.
Laser Print Bottom Cabinet
Replace the laser print Bottom Cabinet for a new one.
2.
No Laser Print Cabinet (Model number label)
Swap the model number label for a new one after exchanging the Bottom Cabinet.
Note:
Repair and return customers’ unit as same as customers send the repair unit to your service center.
(Do not mix the laser print Bottom Cabinet with No laser print Bottom Cabinet.)
1-6-2. Unit with Model Number Label
Repaste the model number label after replacing Bottom Cabinet.
DCR-SX40E (E: PAL)
A-1717-175-A   CABINET (40E, E36), (BOTTOM)
Serial No.
Part No.
Description
DCR-SX60E (E: PAL)
A-1717-176-A   CABINET (60E, E36), (BOTTOM)
Serial No.
Part No.
Description
A-1701-447-A   CABINET ASSY, BOTTOM
Model Number Label
Part No.
Description
1-4
ENGLISH
JAPANESE
ENGLISH
JAPANESE
DCR-SX30E/SX31E/SX40/SX40E/SX41/SX41E/SX50E/SX60/SX60E_L2
1. SERVICE  NOTE
1-1. 修理時の電源供給について
本機では,安定化電源(8.4Vdc)からバッテリ端子に電源を供給した場合,約10秒後にシャットオフし,動作しなくなりま
す。
これを避けるため,下記の方法を用いてください。
方法:
DC入力端子を使用する。(ACアダプタ(AC-L200C/L200D)を使用する。)
1-2. VC-560基板交換または内蔵メモリー(IC8701)交換時の注意
VC-560基板または内蔵メモリー(VC-560基板IC8701)を交換の際は,Adjust  StationからAdjust  Manualを起動させて
「INTERNAL MEMORY ADJUSTMENTS」を参照してください。
1-3. VC-560基板交換時の注意
仕向けデータ
補修用基板と交換する時,補修用基板に書かれている仕向けデータは元の設定と違っている場合があります。
Adjust StationからAdjust Manualを起動させて「DESTINATION DATA WRITE」を実行させてください。
リストアデータ
補修用基板と交換する時,交換前の基板よりデータを取得してください。
データの取得はAdjust StationからAdjust Manualを起動させて「RESTORE DATA」を実行させてください。
本機で取得されるデータは下記になります。
• USB SERIAL No.
USBシリアルNo.
セットは,1台毎に異なる固有のID(USB Serial No.)を書き込んだ後,出荷されています。
新品の補修用基板には,このIDが書き込まれていないので,基板交換後にIDを入力する必要があります。
Adjust StationからAdjust Manualを起動させて「USB SERIAL No. INPUT」を実行させてください。
1-4. 使用サービス治具
延長ケーブル80P(J-6082-718-A)をDA-045基板CN1101とVC-560基板CN1001の間に接続します。
CN1101
CN1001
DA-045基板 (A面側)
VC-560基板 (B面側)
延長ケーブル80P
(J-6082-718-A)
1-5
ENGLISH
JAPANESE
ENGLISH
JAPANESE
DCR-SX30E/SX31E/SX40/SX40E/SX41/SX41E/SX50E/SX60/SX60E_L2
1-5. 自己診断機能
1-5-1.
自己診断機能について
本機の動作に不具合が生じたとき,自己診断機能が働き,
L C D 画面に,どう処置したらよいか判断できる表示を行い
ます。自己診断機能については取扱説明書にも掲載されて
います。
1-5-2.
自己診断表示
本機の動作に不具合が生じたとき,L C D 画面のカウンタ表
示部分がアルファベットと数字の4桁表示になり,3.2Hzで
点滅します。この5 文字の表示によって対応者分類および不
具合の生じたブロックの分類,不具合の詳細コードを示し
ます。
1 1
3 1
C
対応者分類 
「1-5-3. 自己診断コード表」 
を参照 
対応方法の違いにより分類 
例 
 
31 ・・ ・テープを入れ直す 
 
 
32 ・・ ・電源を入れ直す 
ブロック分類 
詳細コード 
3.2Hz点滅 
C  :お客さま自身で対応 
H  :販売店で対応 
E  :サービスエンジニア 
 
で対応 
LCD画面 
C : 3 1 : 1 1
症状/状態
標準以外のバッテリを使用している
“メモリースティック デュオ”が正
しく初期化されていない
“メモリースティック デュオ”が壊
れている
アクセスエラー
フラッシュメモリが書き換えられて
いる
ドライブ不良
フォーカスが合いにくい
(フォーカスの初期化ができない)
ズーム動作の異常(ズームレンズの
初期化ができない)
フォーカス,ズーム異常
フラッシュメモリの書込み/消去動
作不良
内蔵メモリー不良
対応/方法
インフォリチウムバッテリを使用する。
“メモリースティック デュオ”を初期化する。
新しい“メモリースティック デュオ”に交換する。
電源を外し,再度入れ直してから操作する。
フラッシュメモリのデータを元の値に戻す。(注1)
内蔵メモリー(VC-560基板IC8701)を点検または交換す
る。(注2)
タッチパネルでフォーカス操作をしたときにフォーカス動
作をすれば,レンズブロックのフォーカスリセットセンサ
(VC-560基板CN5401 8ピン)を点検する。フォーカス動
作をしなければフォーカスモータ駆動回路(VC-560基板
IC5401)を点検する。
ズームレバーを操作したときにズーム動作をすれば,レン
ズブロックのズームリセットセンサ(VC-560基板CN5401
q;
ピン)を点検する。ズーム動作をしなければズームモー
タ駆動回路(VC-560基板IC5401)を点検する。
フレキ切れ,半差し等の点検を行う。問題がない場合は
フォーカス/ズームモータ駆動IC(VC-560基板IC5401)周辺
回路を点検する。
フラッシュメモリ(VC-560基板IC7801)を点検する。
内蔵メモリー(VC-560基板IC8701)を初期化する。
内蔵メモリー(VC-560基板IC8701)を点検または交換す
る。(注2)
1-5-3. 自己診断コード表
C
C
C
E
E
E
E
E
E
E
ブロック
機能
0
4
1
3
1
3
2
0
3
1
6
1
6
1
6
1
9
4
9
4
詳細
コード
0
0
0
1
0
2
0
0
0
0
0
0
1
0
1
1
0
0
0
1
自己診断コード
注1:Adjust StationからAdjust Manualを起動させて「DESTINATION DATA WRITE」を参照してください。
注2:Adjust StationからAdjust Manualを起動させて「INTERNAL MEMORY ADJUSTMENTS」を参照してください。
Page of 74
Display

Click on the first or last page to see other DCR-SX30E / DCR-SX31E / DCR-SX40 / DCR-SX40E / DCR-SX41 / DCR-SX41E / DCR-SX50E / DCR-SX60 / DCR-SX60E (serv.man2) service manuals if exist.