DOWNLOAD Sony DCR-SR32E / DCR-SR33E / DCR-SR42 / DCR-SR42A / DCR-SR42E / DCR-SR52E / DCR-SR62 / DCR-SR62E / DCR-SR72E / DCR-SR82 / DCR-SR82C / DCR-SR82E (serv.man4) Service Manual ↓ Size: 753.77 KB | Pages: 56 in PDF or view online for FREE

Model
DCR-SR32E DCR-SR33E DCR-SR42 DCR-SR42A DCR-SR42E DCR-SR52E DCR-SR62 DCR-SR62E DCR-SR72E DCR-SR82 DCR-SR82C DCR-SR82E (serv.man4)
Pages
56
Size
753.77 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-sr32e-dcr-sr33e-dcr-sr42-dcr-sr42a-dcr-sr42e-d.pdf
Date

Sony DCR-SR32E / DCR-SR33E / DCR-SR42 / DCR-SR42A / DCR-SR42E / DCR-SR52E / DCR-SR62 / DCR-SR62E / DCR-SR72E / DCR-SR82 / DCR-SR82C / DCR-SR82E (serv.man4) Service Manual ▷ View online

6-43
DCR-SR32E/SR33E/SR42/SR42A/SR42E/SR52E/SR62/SR62E/SR72E/SR82/SR82C/SR82E_ADJ
4) If the [End] button is clicked, the following screen is displayed
during the execution of “4. Transmissive Mode White Balance
Adj.”. Check that the LCD screen is not colored. If colored,
using the [Up]/[Down] button on the screen, adjust so that the
LCD screen is not colored. After the adjustment, click the [End]
button in the screen.
5) If the [End] button is clicked, “5. Reflective Mode White Bal-
ance Adj.” will be executed.
6) Upon successful completion of the “5. Reflective Mode White
Balance Adj.”, “6. Release of Data Setting during LCD Adj.”
will be executed.
7) Upon successful completion of all item the LCD Adjustment,
the following message is displayed. Click the [OK] button.
3.
LCD Adjustment
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during LCD Adj.
2. LCD Automatic Adj.
(VCO Adj., Contrast Adj.)
3. V-COM Adj.
4. Transmissive Mode White Balance Adj.
5. Reflective Mode White Balance Adj. (MEGA model only)
6. Release of Data Setting during LCD Adj.
[Adjusting method]
1) Click the [Start] button of the LCD Adjustment.
2) The Automatic Adjustment Program executes the “1. Data
Setting during LCD Adj.” and “2. LCD Automatic Adj.”.
3) After that, the following screen is displayed during the execu-
tion of “3. V-COM Adj.”. Using the [Up]/[Down] button on the
screen, adjust so that the brightness of portions A and B on the
LCD panel is equal. After the adjustment, click the [End] but-
ton in the screen.
6-44
DCR-SR32E/SR33E/SR42/SR42A/SR42E/SR52E/SR62/SR62E/SR72E/SR82/SR82C/SR82E_ADJ
4.
Touch Panel Adjustment
[Automatic Adjustment Program execution items and
sequence]
1. Touch Panel Adj.
2. Release of Data Setting during LCD Adj.
[Adjusting method]
1) Click the [Start] button of the Touch Panel Adjustment.
2) The Automatic Adjustment Program executes the “1. Touch
Panel Adj.1”. The following message is displayed, and then
adjust the LCD screen in accordance with the instructions given
on the screen. After the adjustment, click the [OK] button in
the message window.
3) If the [OK] button is clicked, “2. Release of Data Setting dur-
ing LCD Adj.” will be executed.
4) Upon successful completion of all item the Touch Panel Ad-
justment, the following message is displayed. Click the [OK]
button.
6-45
DCR-SR32E/SR33E/SR42/SR42A/SR42E/SR52E/SR62/SR62E/SR72E/SR82/SR82C/SR82E_ADJ
1-10. ERROR
In the case of an error during the execution of adjustment, the
Automatic Adjustment Program interrupts the processing at that
point, and displays an error message, and then terminates the pro-
gram execution there.
1-10-1. Error Message
When an error message is displayed, perform the remedy given
below, and then retry adjustment. If the error message is displayed
though the remedy was performed, the circuits will be faulty.
1.
Connect Error, Adjust Control Error
Fig. 6-1-20
Symptom
USB communication with the set is abnormal.
Cause
• USB cable is not inserted tightly.
• Power supply is not installed correctly.
• Communication with SeusEX is abnormal.
Remedy
• Disconnect the USB cable once, and then re-
connect it tightly and check that the set is in
“USB Mode”.
• Install the power supply correctly.
• Start the SeusEX and click the [Connect]  to
check that the connection state is established.
2.
RESET the CAMERA and Try Again
Fig. 6-1-21
Symptom
The camera is not ready for adjustment.
Cause
Data error exists in the camera.
Remedy
Reset the camera.
3.
Adjustment Time  Out
Fig. 6-1-22
Symptom
Adjustment does not finish within the specified
time.
Cause
• Adjustment conditions are wrong.
• Data error exists in the camera.
Remedy
• Check that the conditions such as a subject
are correct.
• Reset the camera.
4.
Adjustment NG
Fig. 6-1-23
Symptom
The adjusted data does not become the speci-
fied value.
Cause
• Adjustment conditions are wrong.
• Data error exists in the camera.
Remedy
• Check that the conditions such as a subject
are correct.
• Reset the camera.
This part indicates 
the adjustment 
item in which 
an error occurred.
This part indicates 
the adjustment 
item in which 
an error occurred.
6-46
DCR-SR32E/SR33E/SR42/SR42A/SR42E/SR52E/SR62/SR62E/SR72E/SR82/SR82C/SR82E_ADJ
1-10-2. Precautions When an Error Occurred
The Automatic Adjustment Program sets the data for adjustment
before the adjustment starts. Accordingly, if the adjustment termi-
nates by an error, the data during the adjustment may be left in the
camera.
Note:
With this data left in the camera, the camera will not oper-
ate normally.
In this case, the [Release Data Setting] button is displayed in “red”
on the screen as shown in Fig. 6-1-24 to Fig. 6-1-26. Click the
[Release Data Setting] button to cancel the data setting. When the
data setting is cancelled, the button color becomes “white”.
Video System Adjustment screen
Fig. 6-1-24
Camera System Adjustment screen
Fig. 6-1-25
LCD System Adjustment screen
Fig. 6-1-26
Ver. 1.7  2008.04