Movie / SECTION 6 ADJUSTMENTS
File
dcr-sr32e-dcr-sr33e-dcr-sr42-dcr-sr42a-dcr-sr42e-d.pdf
Date

Sony DCR-SR32E / DCR-SR33E / DCR-SR42 / DCR-SR42A / DCR-SR42E / DCR-SR52E / DCR-SR62 / DCR-SR62E / DCR-SR72E / DCR-SR82 / DCR-SR82C / DCR-SR82E (serv.man4) Service Manual ▷ View online

6-23
DCR-SR32E/SR33E/SR42/SR42A/SR42E/SR52E/SR62/SR62E/SR72E/SR82/SR82C/SR82E_ADJ
6.
CAMERA Adjustment 3
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 3.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
4) If the [OK] button is clicked, “2. Flange Back Check” is ex-
ecuted. The following messages are displayed, and then oper-
ate the camera to make a check in accordance with the mes-
sages.
5) Upon completion of “2. Flange Back Check”, “3. Release of
Data Setting during Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 3, the following message is displayed. Click the
[OK] button.
Ver. 1.7  2008.04
6-24
DCR-SR32E/SR33E/SR42/SR42A/SR42E/SR52E/SR62/SR62E/SR72E/SR82/SR82C/SR82E_ADJ
7.
CAMERA Adjustment 4
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Optical Axis Adj.
3. Release of Data Setting during Camera Adj.
[Preparation]
1) Connect a DV camcorder to the monitor TV.
2) Playback the monoscope segment of the DV system check tape
(XH5-5 (NTSC), XH5-5P (PAL)).
3) Attach the optical axis frame chart (transparent) on the moni-
tor TV screen. Center of monoscope image and that of optical
axis frame must be agree.
4) Disconnect the DV camcorder from the monitor TV, and con-
nect the HDD camcorder to the monitor TV.
[Adjusting method]
1) Select the model (NTSC Model or PAL Model) with the Model
Select radio button.
Note
: NTSC model: DCR-SR42/SR42A
PAL model: DCR-SR32E/SR33E/SR42E
2) Click the [Start] button of the CAMERA Adjustment 4.
3) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
4) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
5) If the [OK] button is clicked, “2. Optical Axis Adj.” is executed.
The following messages are displayed, and then operate the
camera in accordance with the messages.
6) After that, the following screen is displayed. Check on the
monitor TV which area of optical axis deviation specification
frame the dot exists in. (Detect the deviation direction from
the center of screen.)
• If the deviation amount falls within a circle of which diameter
is 5.5% of the vertical view angle, click the [Within 5.5   ] but-
ton.
• If the deviation amount exists outside a circle of 5.5% of ver-
tical view angle but within a circle of 11%, click the Area but-
ton on “5.5% to 11%”.
• If the deviation amount exists outside a circle of which diam-
eter is 11% of the vertical view angle, click the Area button on
“Outside 11%”.
7) After selecting the area, click the [End] button in the screen.
8) If the [End] button is clicked, “3. Release of Data Setting dur-
ing Camera Adj.” is executed.
9) Upon successful completion of all items of the CAMERA
Adjustment 4, the following message is displayed. Click the
[OK] button.
%
6-25
DCR-SR32E/SR33E/SR42/SR42A/SR42E/SR52E/SR62/SR62E/SR72E/SR82/SR82C/SR82E_ADJ
8.
CAMERA Adjustment 5
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting (Center Frame)
3. F No. Standard Data Input
4. MAX GAIN Adj.
5. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Select the model (NTSC Model or PAL Model) with the Model
Select radio button.
Note:
NTSC model: DCR-SR42/SR42A
PAL model: DCR-SR32E/SR33E/SR42E
2) Click the [Start] button of the CAMERA Adjustment 5.
3) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
4) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed during the
execution of “2. Picture Frame Setting (Center Frame)”. Set
the subject in accordance with the message.
5) If the [OK]  button is clicked, the following message is dis-
played, and then check the size of clear chart shot on the moni-
tor screen.
6) After the checking, if the [OK] button in the message window
is clicked, the adjustment items from “3. F No. Standard Data
Input” to “5. Release of Data Setting during Camera Adj.” are
executed.
7) Upon successful completion of all items of the CAMERA
Adjustment 5, the following message is displayed. Click the
[OK] button.
Ver. 1.7  2008.04
6-26
DCR-SR32E/SR33E/SR42/SR42A/SR42E/SR52E/SR62/SR62E/SR72E/SR82/SR82C/SR82E_ADJ
9.
CAMERA Adjustment 6
[Switch setting]
1. POWER switch ............................................................ Movie
2. NIGHTSHOT PLUS switch ........................................ OFF
3. (HOME) menu - (SETTINGS) - MOVIE SETTINGS
WIDE SELECT ........................................................... 4:3
[Picture Frame Setting (Color reproduction adjustment
frame)]
1) Shoot the color bar chart.
PTB-450: 1 m from the front of lens
PTB-1450: 40 cm from the front of lens
2) Adjust the zoom and the camera direction, and set the speci-
fied position.
Check on the oscilloscope
1. Horizontal period
2. Vertical period
Check on the monitor TV (Underscanned mode)
Fig. 6-1-14
[Adjusting method]
1) Click the [Start]  button in CAMERA Adjustment 6, and the
following screen will appear.
2) Select the model (NTSC or PAL) with the Model Select radio
button.
Note:
NTSC model: DCR-SR42/SR42A
PAL model: DCR-SR32E/SR33E/SR42E
3) Click the [Color Reproduction Adjustment] button.
4) The following message will be displayed, and then shoot the
color bar chart and set the picture frame, and then click the
[OK] button.
(Refer to “Picture Frame Setting”)
A = B
C = D
A
B
C
D
H
E = F
V
E
F
Color bar chart picture frame