DOWNLOAD Sony DCR-SR32E / DCR-SR33E / DCR-SR42 / DCR-SR42A / DCR-SR42E / DCR-SR52E / DCR-SR62 / DCR-SR62E / DCR-SR72E / DCR-SR82 / DCR-SR82C / DCR-SR82E (serv.man4) Service Manual ↓ Size: 753.77 KB | Pages: 56 in PDF or view online for FREE

Model
DCR-SR32E DCR-SR33E DCR-SR42 DCR-SR42A DCR-SR42E DCR-SR52E DCR-SR62 DCR-SR62E DCR-SR72E DCR-SR82 DCR-SR82C DCR-SR82E (serv.man4)
Pages
56
Size
753.77 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-sr32e-dcr-sr33e-dcr-sr42-dcr-sr42a-dcr-sr42e-d.pdf
Date

Sony DCR-SR32E / DCR-SR33E / DCR-SR42 / DCR-SR42A / DCR-SR42E / DCR-SR52E / DCR-SR62 / DCR-SR62E / DCR-SR72E / DCR-SR82 / DCR-SR82C / DCR-SR82E (serv.man4) Service Manual ▷ View online

6-19
DCR-SR32E/SR33E/SR42/SR42A/SR42E/SR52E/SR62/SR62E/SR72E/SR82/SR82C/SR82E_ADJ
2.
Adjustment Items of Camera System Adjustment
The adjustment items of camera system adjustment are as listed in
Table 6-1-5. The Automatic Adjustment Program divides the ad-
justment items into seven, camera adjustment 1-7. Clicking either
CAMERA Adjustment Start button allows the adjustment item
which corresponds to that button to be executed.
The adjustment conditions of the subject and filter vary depend-
ing on which item is adjusted. The Adjustment Program displays
an instruction for the subject and filter as a message during the
adjustment.
Table 6-1-5
Block
Page
Address
CAMERA
Adjustment 1
HALL Adj.
Not required
11
61
0250 to 0258
Siemens star chart with ND filter for
minipattern box (Note) or
Flange back adjustment jig
Flange back adjustment chart and
subject more than 500 m away
CAMERA
Adjustment 3
Flange Back Check
Siemens star chart
-
-
-
CAMERA
Adjustment 4
Optical Axis Adj.
Clear chart
(2.0 m from the front of lens)
11
61
0E04, 0E05
F No. Standard Data Input
11
61
0260 to 026F
MAX GAIN Adj.
11
61
025E
Color Reproduction Adj.
Color bar chart and Clear chart
(Color reproduction adjustment frame)
11
61
0061, 0063,
0067, 0068
Color Reproduction Check
Color bar chart
(Color reproduction adjustment frame)
-
-
-
AWB Standard Data Input
11
61
0074 to 007B
LV Standard Data Input
11
61
025C, 025D
AWB Adj.
Clear chart
(All White frame)
Filter C14 for color temperature
correction
11
61
0070 to 0073,
008C to 0093
AWB Check
Clear chart
(All White frame)
ND filter 1.0, 0.4 and 0.1
-
-
-
CAMERA
Adjustment 7
0020 to 0030,
004C, 004D
Note:
 Dark Siemens star chart.
Clear chart
(All White frame)
61
11
CAMERA
Adjustment 2
Flange Back Adj.
Clear chart
(Center frame)
CAMERA
Adjustment 5
CAMERA
Adjustment 6
Subject
Adjustment
Button Name
Adjusting Address
Ver. 1.7  2008.04
6-20
DCR-SR32E/SR33E/SR42/SR42A/SR42E/SR52E/SR62/SR62E/SR72E/SR82/SR82C/SR82E_ADJ
3.
CAMERA Adjustment 1
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. HALL Adj.
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 1.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) If “1. Data Setting during Camera Adj.” completed success-
fully, and the items “2. HALL Adj.” and “3. Release of Data
Setting during Camera Adj.” will be executed.
4) Upon successful completion of all items of the CAMERA
Adjustment 1, the following message is displayed. Click the
[OK] button.
6-21
DCR-SR32E/SR33E/SR42/SR42A/SR42E/SR52E/SR62/SR62E/SR72E/SR82/SR82C/SR82E_ADJ
[Preparation (Using the flange back adjustment jig)]
(Illuminance: 950 to 1050 lux)
Note 2:
When using the flange back adjustment jig, take care of
the following points:
• For the illumination, use a light source such as an in-
candescent lamp or inverter type fluorescent light free
from flickering.
• Do not make an adjustment in the environment where
fluorescent lamp flickering occurs even if the illumi-
nance can be ensured with the room illumination only.
Use an incandescent lamp or inverter type fluorescent
light at a place free from the influence of room illumi-
nation.
1) Install the flange back adjustment jig so that the distance be-
tween it and the front of lens of camera is less than 3 cm.
2) Make the height of flange back adjustment jig and the camera
equal.
3) Check that the center of chart meets the center of shot image
screen with the zoom lens at TELE end and WIDE end respec-
tively.
Fig. 6-1-13
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation”.
4) If the [OK] button is clicked, “2. Flange Back Adj.” and “3.
Release of Data Setting during Camera Adj.” will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 2, the following message is displayed. Click the
[OK] button.
4.
CAMERA Adjustment 2
(Using the minipattern box or flange back adjust-
ment jig)
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Adj.
3. Release of Data Setting during Camera Adj.
[Preparation (Using the minipattern box)]
1) The minipattern box is installed as shown in the following fig-
ure.
Note:
 The attachment lenses are not used.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage 
± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the
minipattern box.
Fig. 6-1-12
Minipattern box
Below 3 cm
Camera
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
 0.01 Vdc
Output current : more than 3.5 A
Flange back adjustment jig
Below 3 cm
Camera
Ver. 1.7  2008.04
6-22
DCR-SR32E/SR33E/SR42/SR42A/SR42E/SR52E/SR62/SR62E/SR72E/SR82/SR82C/SR82E_ADJ
5.
CAMERA Adjustment 2
(Using the flange back adjustment chart and
subject more than 500 m away)
5-1. CAMERA Adjustment 2 (1)
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back (1) Adj.
3. Release of Data Setting during Camera Adj.
[Preparation]
1) Place the Flange back adjustment chart at 2 m position away
from the lens.
2) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
[Adjusting method]
1) Click the [Start $1%] button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation”.
4) If the [OK] button is clicked, “2. Flange Back (1) Adj.” and “3.
Release of Data Setting during Camera Adj.” will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 2 (1), the following message is displayed. Click
the [OK] button.
6) Perform “CAMERA Adjustment 2 (2)”.
5-2. CAMERA Adjustment 2 (2)
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back (2) Adj.
3. Release of Data Setting during Camera Adj.
[Preparation]
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the screen)
[Adjusting method]
1) Click the [Start $2%] button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation”.
4) If the [OK] button is clicked, “2. Flange Back (2) Adj.” will be
executed.
The following message is displayed during the execution of
adjustment, and then place the ND filter on the lens so as to
obtain the optimum image.
5) If “2. Flange Back Adj.” completed successfully, “3. Release
of Data Setting during Camera Adj.” will be executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 2 (2), the following message is displayed. Click
the [OK] button.
Ver. 1.7  2008.04
Page of 56
Display

Click on the first or last page to see other DCR-SR32E / DCR-SR33E / DCR-SR42 / DCR-SR42A / DCR-SR42E / DCR-SR52E / DCR-SR62 / DCR-SR62E / DCR-SR72E / DCR-SR82 / DCR-SR82C / DCR-SR82E (serv.man4) service manuals if exist.