6-19
DCR-SR30E/SR40/SR40E_ADJ
1-4.
HDD SYSTEM ADJUSTMENTS
If HDD is replaced, perform work following the procedure given
below.
[HDD replacement procedure]
1) Connect the adjustment remote commander to the camcorder
before HDD adjustment, and turn on the power of the
camcorder.
2) Select page:  0, address: 01, and set data: 01.
3) Select page: 9, address: 08, and set data: 01, then press the
PAUSE (Write) button.
4) Select page: 9, address: 10, and set data: 01, then press the
PAUSE (Write) button.
5) Select page: 0, address: 01, and set data: 00.
6) Turn off the power of the camcorder.
7) Replace the HDD.
8) Turning on the power of the camcorder will start automatic
HDD check. During the execution of HDD check, the color
bar is displayed on the LCD screen as shown below.
Note:
Do not vibrate the camcorder or give a shock to it during
the execution of HDD check.
9) Upon successful completion of HDD check, the following
screen will appear. Select “Yes” on the touch panel and wait
for the completion of processing. (If the processing is com-
pleted, normal screen will be restored.)
10) Select page: 0, address: 01, and set data: 01.
11) Select page: 9, address: 10, and check that the data is “00”.
12) Select page: 9, address: 08, and set data: 00, then press the
PAUSE (Write) button.
13) Select page: A, address: 14, and set data: 01, then press the
PAUSE (Write) button.
14) Connect the PC and camcorder with the USB cable.
15) Perform “Initialization of Flash Backup Information”. (See
Page 6-20)
6-20
DCR-SR30E/SR40/SR40E_ADJ
3.
Initialization of AV Index Information
When the following parts are replaced, perform “Initialization of
AV Index Information” after replacement.
VC-466 board
IC2303 (EEPROM) on the VC-466 board
[Initializing method]
1) Click the [Start] button of the Initialization of AV Index Infor-
mation.
2) The initialization finishes when the following message is dis-
played.
2.
Initialization of Flash Backup Information
When HDD is replaced, perform “Initialization of Flash Backup
Information” after replacement. (See HDD replacement proce-
dure)
When the self diagnostic code E:94:00 or E:94:01 is displayed,
perform “Initialization of Flash Backup Information” after re-
pair.
[Initializing method]
1) Click the [Start] button of the Initialization of Flash Backup
Information.
2) The initialization finishes when the following message is dis-
played.
1-5. INITIALIZATION OF INFORMATION DATA
1.
Function of Each Button on Initialization of Informa-
tion Data Screen
Click the [Initialization of Information Data] button on the Main Menu
screen, and the “Initialization of Information Data” screen in Fig.
6-1-7 will appear.
Fig. 6-1-7
1
[To Menu] button
The Main Menu screen comes back.
2
[Start] button
Initialization of Flash Backup Information
 or 
Initial-
ization of AV Index Information
 starts.
2
1
6-21
DCR-SR30E/SR40/SR40E_ADJ
1-6.
VIDEO SYSTEM ADJUSTMENTS
1.
Function of Each Button on Video System
Adjustment Screen
Click the
 [VIDEO SYSTEM ADJUSTMENT]
 button on the Main
Menu screen, and the “VIDEO SYSTEM ADJUSTMENT” screen
in Fig. 6-1-8 will appear.
Fig. 6-1-8
1
[To Menu]
 button
The Main Menu screen comes back.
2
[Preparation]
 button
Notes for adjustment or jigs used are displayed.
3
[Start]
 button
“Video Adjustment” starts.
4
[Release Data Setting]
 button
The data setting at the adjustment is cancelled.
During the data setting, the button color changes from “white”
to “red”. When the data setting is cancelled, the button color
returns to “white”.
(Use this button when an error occurred in the video adjust-
ment. If the adjustment completed successfully, the data set-
ting is automatically cancelled and the button color returns to
“white”.)
2.
Adjustment Items of VIDEO System Adjustment
The adjustment items of video system adjustment are as listed in
Table 6-1-2. The Automatic Adjustment Program executes the ad-
justment items if the VIDEO Adjustment Start button is clicked.
4
3
2
1
Note:
 The Automatic Adjustment Program does not support.
Table 6-1-2
Button
Name
Adjustment
Measurement Point
Measuring
Instrument
Adjustment
Page
Adjustment
Address
(Note)
36 MHz Origin
Oscillation Adj.
Frequency
counter
0F
10
S VIDEO OUT Y
Level Adj.
Y signal terminal of S VIDEO plug of
A/V jack (75 ohm terminated)
Pin qh of IC1101 (ADCLK) on 
VC-466 board
Oscilloscope
0C
25
S VIDEO OUT
Chroma Level Adj.
Chroma signal terminal of S VIDEO
plug of A/V jack (75 ohm terminated)
Oscilloscope
0C
26, 27
VIDEO OUT  Level
Check
VIDEO terminal of A/V jack (75 ohm
terminated)
Oscilloscope
VIDEO
Adjustment
6-22
DCR-SR30E/SR40/SR40E_ADJ
4.
VIDEO Adjustment
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Video Adj.
2. S VIDEO OUT Y Level Adj.
3. S VIDEO OUT Chroma Level Adj.
4. VIDEO OUT Level Check
5. Release of Data Setting during Video Adj.
[Adjusting method]
1) Click the 
[Start]
 button of the VIDEO Adjustment.
2) The Automatic Adjustment Program executes the “1. Data
Setting during Video Adj.”.
3) If “1. Data Setting during Video Adj.” completed successfully,
the following screen is displayed during the execution of “2. S
VIDEO OUT Y Level Adj.”. Using the 
[Up]
 / 
[Down]
 button
on the screen, adjust so that the Y signal level satisfies the
specified value.
3.
36 MHz Origin Oscillation Adjustment
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Subject
Not required
Measurement Point
Pin qh of IC1101 (ADCLK) on
VC-466 board
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified value
f = 18000000 
±
 90 Hz
Switch setting
1) POWER ............................................................. MOVIE mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
F
10
Change the data and set the
frequency (f) to the specified
value.
3
F
10
Press PAUSE button.
4
0
01
00
Fig. 6-1-9
VC-466 BOARD (SIDE A)
IC1101
25
24
36
37
48
13
16
12
1