DOWNLOAD Sony DCR-SR30E / DCR-SR40 / DCR-SR40E (serv.man4) Service Manual ↓ Size: 662.66 KB | Pages: 54 in PDF or view online for FREE

Model
DCR-SR30E DCR-SR40 DCR-SR40E (serv.man4)
Pages
54
Size
662.66 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-sr30e-dcr-sr40-dcr-sr40e-sm4.pdf
Date

Sony DCR-SR30E / DCR-SR40 / DCR-SR40E (serv.man4) Service Manual ▷ View online

6-11
DCR-SR30E/SR40/SR40E_ADJ
6.
D Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 9, A, B, D, 13, 15, 17, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 9, A, B, D, 13, 15, 17, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
10 to 13
Fixed data-1 (Initialized data)
14
Fixed data-2
15
Fixed data-1 (Initialized data)
16
17
Fixed data-2
18 to 27
Fixed data-1 (Initialized data)
28
29
2A
2B
2C
Fixed data-2
2D
2E
2F
30
31, 32
Fixed data-1 (Initialized data)
33
Fixed data-2
34 to 48
Fixed data-1 (Initialized data)
49
Fixed data-2
4A
Fixed data-1 (Initialized data)
4B
Fixed data-2
4C, 4D
Fixed data-1 (Initialized data)
4E
Fixed data-2
4F to 56
Fixed data-1 (Initialized data)
57
Fixed data-2
58 to 7F
Fixed data-1 (Initialized data)
10. 1A Page table
Note 1:
If reading/writing data on pages 1A, set data: 01 to page:
0, address: 10, and then select pages: A. By this data set-
ting, the pages 1A can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 9, A, B, D, 13, 15, 17, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 9, A, B, D, 13, 15, 17, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
11. 1B Page table
Note 1:
If reading/writing data on pages 1B, set data: 01 to page:
0, address: 10, and then select pages: B. By this data set-
ting, the pages 1B can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 9, A, B, D, 13, 15, 17, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 9, A, B, D, 13, 15, 17, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
7.
13 Page table
Note 1:
If reading/writing data on pages 13, set data: 01 to page:
0, address: 10, and then select pages: 3. By this data set-
ting, the pages 13 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 9, A, B, D, 13, 15, 17, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 9, A, B, D, 13, 15, 17, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
8.
15 Page table
Note 1:
If reading/writing data on pages 15, set data: 01 to page:
0, address: 10, and then select pages: 5. By this data set-
ting, the pages 15 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 9, A, B, D, 13, 15, 17, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 9, A, B, D, 13, 15, 17, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
9.
17 Page table
Note 1:
If reading/writing data on pages 17, set data: 01 to page:
0, address: 10, and then select pages: 7. By this data set-
ting, the pages 17 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 9, A, B, D, 13, 15, 17, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 9, A, B, D, 13, 15, 17, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
6-12
DCR-SR30E/SR40/SR40E_ADJ
2.
Modification of E, F, 19, 1E, 1F Page Data
If the E, F, 19, 1E, 1F page data has been initialized, change the
data of the “Fixed data-2” address shown in the following table by
manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages E, F, set data: 00 to page: 0,
address: 10, and then select pages E, F.
3) If modification of data on pages 19, 1E, 1F, set data: 01 to
page: 0, address: 10, and then select pages 9, E, F.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note 1:
If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6) Check that the data at the addresses for adjustment are initial
values (adjustment initial values) listed in the table.
If different, change them to the adjustment initial values.
Processing after Completing Modification E, F, 19, 1E, 1F
page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE (Write) button.
Note 2:
This operation should be done with the adjustment re-
mote commander. The operation of page: 02 cannot be
performed with the SeusCam.
1-2-2.
Initialization of E, F, 19, 1E, 1F Page Data
1.
Initializing of E, F, 19, 1E, 1F Page Data
Note 1:
If “Initialization of Pages E, F, 19, 1E, 1F” is executed,
all data on pages E, F, 19, 1E, 1F are initialized. (Only an
individual page cannot be initialized)
Note 2:
If the E, F, 19, 1E, 1F page data has been initialized, the
following adjustments need to be performed again.
1) Modification of E, F, 19, 1E, 1F page data
2) Camera system adjustment
Adjustment Page
E
Adjustment Address
00 to FF
Adjustment Page
F
Adjustment Address
10 to FF
Adjustment Page
19
Adjustment Address
00 to 33
Adjustment Page
1E
Adjustment Address
00 to FF
Adjustment Page
1F
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data Procedure
1
0
01
01
2
0
10
00
Set the following data, and
press PAUSE (Write) button.
3
6
01
2D: NTSC model
2F: PAL model
4
6
03
FF
Press PAUSE (Write) button.
5
Wait for 6 seconds.
6
6
02
Check the data changes to
“01”.
7
Perform “Modification of E,
F, 19, 1E, 1F Page Data”
Note 3:
NTSC model: DCR-SR40
PAL model: DCR-SR30E/SR40E
6-13
DCR-SR30E/SR40/SR40E_ADJ
3.
E Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to“1. Initializing the
E, F, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of E, F, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 07
Fixed data-1 (Initialized data)
08
09
Fixed data-2
0A to 3D
Fixed data-1 (Initialized data)
3E
Fixed data-2
3F to 47
Fixed data-1 (Initialized data)
48
Fixed data-2
49 to 68
Fixed data-1 (Initialized data)
69
Fixed data-2
6A to BF
Fixed data-1 (Initialized data)
C0
Fixed data-2
C1 to C3
Fixed data-1 (Initialized data)
C4
Fixed data-2
C5 to CE
Fixed data-1 (Initialized data)
CF
D0
Fixed data-2
D1 to E3
Fixed data-1 (Initialized data)
E4
E5
Fixed data-2
E6 to E9
Fixed data-1 (Initialized data)
EA
Fixed data-2
EB to F8
Fixed data-1 (Initialized data)
F9
Fixed data-2
FA to FF
Fixed data-1 (Initialized data)
6-14
DCR-SR30E/SR40/SR40E_ADJ
4.
F Page table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the E, F, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of E, F, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
10
80
80
36 MHz origin oscillation adj.
11
Fixed data-1 (Initialized data)
12
50
50
HALL adj.
13
50
50
14
89
89
15
00
00
16
17
17
17
00
00
18
19
19
19
8F
A3
Max gain adj.
1A
36
36
LV standard data input
1B
00
00
1C
00
00
F No. standard data input
1D
00
00
1E
00
00
1F
00
00
20
00
00
21
00
00
22
00
00
23
00
00
24 to 29
Fixed data-1 (Initialized data)
2A
23
27
AWB standard data input
2B
B4
94
2C
08
08
2D
75
95
2E
16
18
AWB adj.
2F
0A
56
30
0D
0E
31
99
2E
32
Fixed data-1 (Initialized data)
33
41
46
Color reproduction adj.
34
Fixed data-1 (Initialized data)
35
2B
2E
Color reproduction adj.
36 to 39
Fixed data-1 (Initialized data)
3A
00
00
Color reproduction adj.
3B
F0
EE
3C, 3D
Fixed data-1 (Initialized data)
3E
2B
2B
AWB adj.
3F
58
58
40
5A
5B
41
40
D0
42, 43
Fixed data-1 (Initialized data)
44
3A
3A
Flange back adj.
45
74
74
Address
Initial value
Remark
NTSC PAL
46
3F
3F
Flange back adj.
47
2C
2C
48
17
17
49
4A
4A
4A
00
00
4B
00
00
4C
00
00
4D
00
00
4E
4F
4F
4F
19
19
50
00
00
51
30
30
52
04
04
53
00
00
54
00
00
55
00
00
56 to 63
Fixed data-1 (Initialized data)
64
65
Fixed data-2
66 to 8C
Fixed data-1 (Initialized data)
8D
Fixed data-2
8E to 92
Fixed data-1 (Initialized data)
93
94
Fixed data-2
95 to 99
Fixed data-1 (Initialized data)
9A
Fixed data-2
9B
Fixed data-1 (Initialized data)
9C
Fixed data-2
9D to A8
Fixed data-1 (Initialized data)
A9
AA
Fixed data-2
AB
Fixed data-1 (Initialized data)
AC
Fixed data-2
AD to BC
Fixed data-1 (Initialized data)
BD
BE
Fixed data-2
BF to C4
Fixed data-1 (Initialized data)
C5
C6
Fixed data-2
C7 to E1
Fixed data-1 (Initialized data)
E2
E3
Fixed data-2
E4 to FF
Fixed data-1 (Initialized data)
Page of 54
Display

Click on the first or last page to see other DCR-SR30E / DCR-SR40 / DCR-SR40E (serv.man4) service manuals if exist.