DOWNLOAD Sony DCR-SR210E / DCR-SR220 / DCR-SR220D / DCR-SR220E / HDR-SR10 / HDR-SR10D / HDR-SR10E (serv.man3) Service Manual ↓ Size: 739.44 KB | Pages: 48 in PDF or view online for FREE

Model
DCR-SR210E DCR-SR220 DCR-SR220D DCR-SR220E HDR-SR10 HDR-SR10D HDR-SR10E (serv.man3)
Pages
48
Size
739.44 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-sr210e-dcr-sr220-dcr-sr220d-dcr-sr220e-hdr-sr1.pdf
Date

Sony DCR-SR210E / DCR-SR220 / DCR-SR220D / DCR-SR220E / HDR-SR10 / HDR-SR10D / HDR-SR10E (serv.man3) Service Manual ▷ View online

6-40
DCR-SR210E/SR220/SR220D/SR220E/
HDR-SR10/SR10D/SR10E_ADJ
6-2. SERVICE  MODE
2-1.
APPLICATION FOR ADJUSTMENT (SeusEX)
The adjustment software (SeusEX) can change operational coeffi-
cients of signal processing, EVR data, etc. same as the adjustment
remote commander. The SeusEX performs two-way communica-
tion between PC and camcorder using the USB terminal. The two-
way communication result data can be written in the nonvolatile
memory.
1.
Connection
1) Connect the HASP key to the USB terminal of the PC.
2) Connect the PC and camcorder with the USB cable.
3) Start the SeusEX on the PC.
4) Click  [Connect]  on the SeusEX screen. If the connection is
normal, the SeusEX screen will be as shown in Fig. 6-2-1,
indicating the “connected” state.
Note:
The SeusEX will go in “disconnect” state, if the
camcorder is turned off (for instance, by resetting the
set). In such a case, click [Connect]  on the SeusEX
screen to restore the “connected” state.
Fig. 6-2-1
2.
Operation
• Block change
To  change the block, click [Block]  on the SeusEX screen and
enter the block to be changed. The block is displayed in hexa-
decimal notation.
• Page change
To change the page, click [Page] on the SeusEX screen and en-
ter the page to be changed. The page is displayed in hexadeci-
mal notation.
• Address change
To  change the address, click [Address]  on the SeusEX screen
and enter the address to be changed. The address is displayed in
hexadecimal notation.
• Data change
To change the data, click [Set] on the SeusEX screen and enter
the data. The data is displayed in hexadecimal notation.
This operation does not write the data to the nonvolatile memory.
• Data writing
To write the data to the EEPROM, click [Write] on the SeusEX
screen and enter the data value to be written.
To  write the data to the flash memory, change the data value
using the [Set] on the SeusEX screen and then click [Save] to
save the data.
• Data reading
The data displayed on the SeusEX screen are the data values at
the time when the pages and addresses were set, and they are
not updated automatically. To check the data change, click [Read]
on the SeusEX screen and update the displayed data.
6-41
DCR-SR210E/SR220/SR220D/SR220E/
HDR-SR10/SR10D/SR10E_ADJ
2.
Switch Check
Click the [Switch Check] button on the SERVICE MODE screen,
and the “SWITCH CHECK” screen will appear.
Using method:
Click the [Start] button, and the switch check will start.
During execution of switch check, the pressed switch is displayed
in orange. Also, once the switch was pressed, its name characters
change to blue in color.
2-2.
SERVICE  MODE
1.
Function of Each Button on Service Mode Screen
Click the [SERVICE MODE] button on the Main Menu screen, and
the “SERVICE MODE” screen in Fig. 6-2-2 will appear.
Fig. 6-2-2
1
[To Menu] button
The Main Menu screen comes back.
2
[Switch Check] button
“SWITCH CHECK” screen appears.
3
[LED Check] button
“LED CHECK” screen appears.
4
[Jack Check] button
“JACK CHECK” screen appears.
5
[Lens Barrier Check] button
“LENS BARRIER CHECK” screen appears.
6
[G Sensor Check] button
“G SENSOR CHECK” screen appears.
7
[Record Data] button
“RECORD DATA” screen appears.
8
[Test Pattern Output] button
“TEST PATTERN OUTPUT” screen appears.
1
2
3
4
5
6
7
8
Ver. 1.3  2008.07
6-42
DCR-SR210E/SR220/SR220D/SR220E/
HDR-SR10/SR10D/SR10E_ADJ
4.
Jack Check
Click the [Jack Check] button on the SERVICE MODE screen,
and the “JACK CHECK” screen will appear.
Using method:
Click the [Start] button, and the jack check will start.
During execution of jack check, the connected jack is displayed in
orange.
Note:
The HDMI OUT jack is displayed in orange when it is con-
nected to a unit that supports HDMI.
3.
LED Check
Click the [LED Check] button on the SERVICE MODE screen,
and the “LED CHECK” screen will appear.
Using method:
LED ON or OFF can be controlled with [LED ON] or [LED OFF]
button on the screen.
6-43
DCR-SR210E/SR220/SR220D/SR220E/
HDR-SR10/SR10D/SR10E_ADJ
5.
Lens Barrier Check
Click the [Lens Barrier Check] button on the SERVICE MODE
screen, and the “LENS BARRIER CHECK” screen will appear.
Using method:
The lens barrier open or close can be controlled with [OPEN] or
[CLOSE] button on the screen.
6.
G Sensor Check
Click the [G Sensor Check] button on the SERVICE MODE screen,
and the following screen will appear.
If the [Reset] button is clicked, the Camcorder is reset and it is
restarted, and then the “G SENSOR CHECK” screen will appear.
Using method:
Click the [Start] button, and the G sensor check will start.
During execution of G sensor check, the conditon of G sensor is
displayed.
Click the [Top] button, and the following message will be displayed.
If the [OK] button is clicked, and Camcorder is reset and it is re-
started, and then the SERVICE MODE screen will come back.
Page of 48
Display

Click on the first or last page to see other DCR-SR210E / DCR-SR220 / DCR-SR220D / DCR-SR220E / HDR-SR10 / HDR-SR10D / HDR-SR10E (serv.man3) service manuals if exist.