6-28
DCR-SR210E/SR220/SR220D/SR220E/
HDR-SR10/SR10D/SR10E_ADJ
HDR-SR10/SR10D/SR10E_ADJ
13) After the checking, if the [OK] button in the message window
is clicked, “12. MAX GAIN Adj.” is executed.
14) Upon successful completion of the “12. MAX GAIN Adj.”,
“13. Release of Data Setting during Camera Adj.” is executed.
15) Upon successful completion of all items of the CAMERA
Adjustment 5, the following message is displayed. Click the
[OK] button.
[OK] button.
6-29
DCR-SR210E/SR220/SR220D/SR220E/
HDR-SR10/SR10D/SR10E_ADJ
HDR-SR10/SR10D/SR10E_ADJ
9.
CAMERA Adjustment 6
Note:
Before performing the defect adjustment, make sure that
the lens temperature of the camcorder 39 ºC to 40 ºC.
the lens temperature of the camcorder 39 ºC to 40 ºC.
[Preparation (Temperature Check)]
1) Click the [Preparation] button of the CAMERA Adjustment 6
1) Click the [Preparation] button of the CAMERA Adjustment 6
to display the Preparation screen.
2) Click the [Temperature Check] button of the Preparation screen,
the following screen will appear.
[Checking method]
Click the [Start] button of the Temperature Check, and the
camcorder will go in the Temperature Check mode and the tem-
perature check result will be displayed on the LCD screen. Per-
form the aging if the check result is NG (below 39 ºC). To exit the
Temperature Check mode, click the [Stop] button.
Click the [Start] button of the Temperature Check, and the
camcorder will go in the Temperature Check mode and the tem-
perature check result will be displayed on the LCD screen. Per-
form the aging if the check result is NG (below 39 ºC). To exit the
Temperature Check mode, click the [Stop] button.
[Aging method]
Set the camcorder to the Movie mode, and place the LCD screen
in the “reverse-closed” state. (In this state, the temperature rises
more quickly than that in other states.)
Set the camcorder to the Temperature Check mode, and wait until
the LCD screen display changes from NG (grid pattern) to OK
(color bars).
Set the camcorder to the Movie mode, and place the LCD screen
in the “reverse-closed” state. (In this state, the temperature rises
more quickly than that in other states.)
Set the camcorder to the Temperature Check mode, and wait until
the LCD screen display changes from NG (grid pattern) to OK
(color bars).
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. White Defect Adj. (FD white point)
3. White Defect Adj.
4. Black Defect Adj.
5. Release of Data Setting during Camera Adj.
sequence]
1. Data Setting during Camera Adj.
2. White Defect Adj. (FD white point)
3. White Defect Adj.
4. Black Defect Adj.
5. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 6.
2) The Automatic Adjustment Program executes “1. Data Setting
1) Click the [Start] button of the CAMERA Adjustment 6.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) If “1. Data Setting during Camera Adj.” completed success-
fully, and the items from “2. White Defect Adj. (FD white
point)” to “3. White Defect Adj.” will be executed.
point)” to “3. White Defect Adj.” will be executed.
4) If “3. White Defect Adj.” completed successfully, the follow-
ing message is displayed. Set the subject in accordance with
the message.
the message.
5) Click the [OK] button, and the “4. Black Defect Adj.” will be
executed.
6) Upon completion of “4. Black Defect Adj.”, “5. Release of
Data Setting during Camera Adj.” is executed.
7) Upon successful completion of all items of the CAMERA Ad-
justment 6, the following message is displayed. Click the [OK]
button.
button.
Ver. 1.3 2008.07
6-30
DCR-SR210E/SR220/SR220D/SR220E/
HDR-SR10/SR10D/SR10E_ADJ
HDR-SR10/SR10D/SR10E_ADJ
10. CAMERA Adjustment 7
Note:
Note:
“CAMERA Adjustment 7” is available only once after the
power is turned on. If the adjustment is retried, turn off the
power and turn on again.
power is turned on. If the adjustment is retried, turn off the
power and turn on again.
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Strobe Light Level & White Balance Adj.
3. Release of Data Setting during Camera Adj.
sequence]
1. Data Setting during Camera Adj.
2. Strobe Light Level & White Balance Adj.
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 7.
2) The Automatic Adjustment Program executes “1. Data Setting
1) Click the [Start] button of the CAMERA Adjustment 7.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
(For the Flash adjustment box, refer to “6. Preparing the Flash
Adjustment Box” (see page 6-6).)
ject in accordance with the message.
(For the Flash adjustment box, refer to “6. Preparing the Flash
Adjustment Box” (see page 6-6).)
4) Press the [OK] button, and the items “2. Strobe Light Level &
White Balance Adj.” will be executed.
5) Upon completion of “2. Strobe Light Level & White Balance
Adj.”, “3. Release of Data Setting during Camera Adj.” is ex-
ecuted
ecuted
6) Upon successful completion of all items of the CAMERA Ad-
justment 7, the following message is displayed. Click the [OK]
button.
button.
6-31
DCR-SR210E/SR220/SR220D/SR220E/
HDR-SR10/SR10D/SR10E_ADJ
HDR-SR10/SR10D/SR10E_ADJ
SE9501
SE9502
FR-285 BOARD (SIDE B)
1
2
3
4
PP
1
2
3
4
YY
YY: YAW sensor
sensitivity S
sensitivity S
9502
PP: PITCH sensor
sensitivity S
sensitivity S
9501
Preparation:
1) Read the PITCH sensor (FR-285 board SE9501) sensitivity
1) Read the PITCH sensor (FR-285 board SE9501) sensitivity
written on repair parts, and named this as S
9501
.
2) Read the YAW sensor (FR-285 board SE9502) sensitivity writ-
ten on repair parts, and named this as S
9502
.
Fig. 6-1-17
How to read the sensitivity data of angular velocity sen-
sor
sor
With the pins 1 and 2 of angular velocity sensor placed in the
lower position, read the data value.
lower position, read the data value.
Description example:
For the sensor sensitivity value 60
Fig. 6-1-18
11. CAMERA Adjustment 8
Perform this adjustment only when replacing the GYRO sensor or
lens block. When the microprocessor, circuit etc. is damaged, don't
perform this adjustment but check the operations only.
lens block. When the microprocessor, circuit etc. is damaged, don't
perform this adjustment but check the operations only.
11-1. Preparation when the GYRO sensor or the FR-
285 board is replaced
Note down the sensitivity displayed on the GYRO sensor of the re-
pair parts. At this time, note down also to which board it was attached
to.
Be sure to check because if attached incorrectly, the screen will vi-
brate up and down or left and right during the steady shot operations.
pair parts. At this time, note down also to which board it was attached
to.
Be sure to check because if attached incorrectly, the screen will vi-
brate up and down or left and right during the steady shot operations.
Precautions on the Parts Replacement
The PITCH sensor and the YAW sensor are different parts.
Precautions on GYRO Sensor
The sensor incorporates a precision oscillator. Handle it with care as
if it dropped, the balance of oscillator will be disrupted and opera-
tions will not be performed properly.
if it dropped, the balance of oscillator will be disrupted and opera-
tions will not be performed properly.
Adjustment Block
11
Adjustment Page
8F
Adjustment Address
FF70, FF71
Note:
The sensor sensitivity of SE9501 and SE9502 of the FR-
285 board is written only repair parts.
285 board is written only repair parts.
6 0
Hand Writing
1
2
4
3
Click on the first or last page to see other DCR-SR210E / DCR-SR220 / DCR-SR220D / DCR-SR220E / HDR-SR10 / HDR-SR10D / HDR-SR10E (serv.man3) service manuals if exist.