1-3
DCR-PC330/PC330E
5.
NOTES ON HANDLING THE LASER DIODE [LASER UNIT (D7609 of FP-706 flexible)]
The laser diode may suffer electrostatic breakdown because of the potential difference generated by the charged electrostatic load, etc. on
clothing and the human body.
During repair, pay attention to electrostatic breakdown and also use the procedure in the printed matter which is included in the repair parts.
The flexible board is easily damaged and should be handled with care.
5-1.
Soldering Conditions of Laser Unit (D7609)
Temperature of
Less than 350 
°
C
the Soldering Iron
Time to Solder
3 seconds
Interval to Solder
Next terminal is soldered after
waiting for 1 second
Note:
Adjustment is needed when laser unit (D7609) is replaced. Refer
to “24. AF Laser Output Adjustment”, “25. AF Laser Axis Check
(1)” and “26. AF Laser Axis Check (2)” of SERVICE MANUAL,
ADJ (987627251.pdf).
Laser Unit (D7609)
1-4
DCR-PC330/PC330E
1-2. SELF-DIAGNOSIS FUNCTION
1.
SELF-DIAGNOSIS FUNCTION
When problems occur while the unit is operating, the self-diagnosis
function starts working, and displays on the viewfinder, or LCD
screen what to do. This function consists of two display; self-
diagnosis display and service mode display.
Details of the self-diagnosis functions are provided in the Instruction
manual.
2.
SELF-DIAGNOSIS DISPLAY
When problems occur while the unit is operating, the counter of the
viewfinder or LCD screen consists of an alphabet and 4-digit number,
which blinks at 3.2Hz. This 5-character display indicates the
“repaired by:”, “block” in which the problem occurred, and “detailed
code” of the problem.
Note:
The self-diagnosis display data will be kept even if the lithium battery (BT9901 of BT-021 board) is removed.
1 1
3 1
C
Repaired by:
Refer to page 1-5.
Self-diagnosis Code Table.
Indicates the appropriate
step to be taken.
E.g.
31 ....Reload the tape.
32 ....Turn on power again.
Block
Detailed Code
Blinks at 3.2Hz
C : Corrected by customer
H : Corrected by dealer
E : Corrected by service
engineer
Viewfinder or LCD screen
C : 3 1 : 1 1
1-5E
DCR-PC330/PC330E
3.
SELF-DIAGNOSIS CODE TABLE
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
E
E
E
E
E
Block
Function
0
4
2
1
2
2
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
1
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
3
2
6
1
6
1
6
2
6
2
9
1
Detailed
Code
0
0
0
0
0
0
1
0
1
1
2
0
2
1
2
2
2
3
2
4
3
0
4
0
4
2
1
0
1
1
2
0
2
1
2
2
2
3
2
4
3
0
4
0
4
2
0
0
1
0
0
0
0
1
0
1
Symptom/State
Non-standard battery is used.
Condensation.
Video head is dirty.
LOAD direction. Loading does not
complete within specified time
UNLOAD direction. Loading does not
complete within specified time
T reel side tape slacking when unloading.
Winding S reel fault when counting the
rest of tape.
T reel fault.
S reel fault.
T reel fault.
FG fault when starting capstan.
FG fault when starting drum.
FG fault during normal drum operations.
LOAD direction loading motor time-
out.
UNLOAD direction loading motor
time-out.
T reel side tape slacking when
unloading.
Winding S reel fault when counting the
rest of tape.
T reel fault.
S reel fault.
T reel fault.
FG fault when starting capstan.
FG fault when starting drum
FG fault during normal drum
operations
Difficult to adjust focus
(Cannot initialize focus.)
Zoom operations fault
(Cannot initialize zoom lens.)
Steadyshot function does not work well.
(With pitch angular velocity sensor output
stopped.)
Steadyshot function does not work well.
(With yaw angular velocity sensor output
stopped.)
Abnormality when the power supply
capacitor of the flash unit is being
charged.
Self-diagnosis Code
Repaired b
y
:
Correction
Use the info LITHIUM battery.
Remove the cassette, and insert it again after one hour.
Clean with the optional cleaning cassette.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Load the tape again, and perform operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Remove the battery or power cable, connect, and perform
operations from the beginning.
Inspect the lens block focus MR sensor (Pin ql, wa of CN1301 of
VC-325 board) when focusing is performed when the focus ring is
rotated in the focus manual mode, and the focus motor drive circuit
(IC1303 of VC-325 board) when the focusing is not performed.
Inspect the lens block zoom MR sensor (Pin qh, qj of CN1301 of
VC-325 board) when zooming is performed when the zoom switch
is operated and the zoom motor drive circuit (IC1303 of VC-325
board) when zooming is not performed.
Inspect pitch angular velocity sensor (SE3502 of VF-158 board)
peripheral circuits.
Inspect yaw angular velocity sensor (SE3501 of VF-158 board)
peripheral circuits.
Checking or replacement of the flash unit.
Ver 1.1  2003. 11
2-1
SECTION 2
DISASSEMBLY
DCR-PC330/PC330E
COVER
COVER
The following flow chart shows the disassembly procedure.
HELP
HELP
DISASSEMBLY
HELP
DISASSEMBLY
HELP
DISASSEMBLY
DISASSEMBLY
DISASSEMBLY
DISASSEMBLY
DISASSEMBLY
DISASSEMBLY
DISASSEMBLY
DISASSEMBLY
DISASSEMBLY
DISASSEMBLY
DISASSEMBLY
HELP
HELP
DISASSEMBLY
SERVICE POSITION TO 
CHECK THE VTR SECTION
PD-198 board 
service position
Discharging the Capacitor
PROCEDURE OF REMOVING THE MECHANISM DECK.
(VTR CHECK SERVICE POSITION) 
1
2-2.  CABINET (F) SECTION ...................................
2
2-3.  CABINET (REAR) SECTION ...........................
3
2-5.  CABINET (R) SECTION ..................................
4
2-6.  TRIPOD SCREW .............................................
5
2-7.  BJ-005 BOARD ................................................
6
2-14.  EVF SECTION ...............................................
7
2-16.  STROBOSCOPE SECTION ..........................
8
2-20.  LENS SECTION ............................................
9
2-21.  FP-706 BOARD - (1) .....................................
0
2-26.  VC-325 BOARD .............................................
(page 2-3)
(page 2-3)
(page 2-4)
(page 2-5)
(page 2-5)
(page 2-11)
(page 2-13)
(page 2-15)
(page 2-15)
(page 2-19)
qa
2-27. MECHANISM DECK ....................................
qs
2-28. AV-081 BOARD ............................................
qd
2-29. JK-257 BOARD ............................................
qf
SERVICE POSITION TO CHECK 
      THE VTR SECTION..............................................
(page 2-19)
(page 2-20)
(page 2-20)
(page 2-21)
Page of 96
Display

Click on the first or last page to see other DCR-PC330 / DCR-PC330E (serv.man2) service manuals if exist.