Sony DCR-PC330 / DCR-PC330E (serv.man2) Service Manual ▷ View online
2-14
DCR-PC330/PC330E
2-18.MIC UNIT (MIC5000)
3
1
Two screws
(M1.7
×
1.8)
2
Two screws
(M1.7
×
2.5),
lock ace, p2 (silver)
4
Two tapping screws
(M1.7
×
3.5) (silver)
5
Two screws
(M1.7
×
2.5) (silver)
qa
Microphone
cushion
7
Hot shoe frame
6
Claw
8
FP-701 flexible
board (10P)
q;
Cabinet (upper)
qs
MIC unit
(MIC5000)
9
External connector
(hot shoe)
1
Two tapping screws
(M1.7
×
5) (black)
2
Claw
3
Stroboscope
cabinet
4
Two
claws
5
Unit cover
assembly
6
Screw (M1.7
×
2.5),
lock ace, p2 (silver)
7
Screw (bolt)
(M1.4
×
3)
8
Stroboscope luminous
unit (ST5000)
switch
When re-assembling,
confirm the switch position.
confirm the switch position.
qs
Stroboscope
assembly
9
Three claws
q;
Blind cabinet
qa
Two cushions
(stroboscope)
Caution
2-19.STROBOSCOPE LUMINOUS UNIT (ST5000), STROBOSCOPE ASSEMBLY
2-15
DCR-PC330/PC330E
2-20.LENS SECTION
VC-
325
325
1
CD-452 board
(80P)
4
FP-706 board (18P)
2
Tape (A)
Tape (A)
3
Flexible board
(from lens device)(33P)
5
Screw
(M1.7
×
2.5),
lock ace, p2(silver)
6
Lens section
Caution
When re-assembling,
attach the tape (A) as shown.
attach the tape (A) as shown.
2-21.FP-706 BOARD - (1)
1
Tapping screw
(M1.7
×
5) (silver)
2
Tapping screw
(M1.7
×
5) (silver)
5
MF ring assembly,
FP-706 board
3
Remove the
four dowels and
convex part
convex part
4
Lens device LSV-870A,
CD-452 board, etc.
2-16
DCR-PC330/PC330E
2-22.FP-706 BOARD - (2)
7
1
Two
claws
2
Screw (M1.7
×
2.5),
lock ace, p2 (silver)
3
Tapping screw
(M1.7
×
3.5) (silver)
4
IR frame
FP-706 board
5
Screw (M1.7
×
2.5),
lock ace, p2 (silver)
6
MF ring assembly
Caution
Caution
q;
FP-706 board
When soldering the laser unit on the FP-706 board,
observe the following things.
(Refer to Service Note (page 1-3)).
observe the following things.
(Refer to Service Note (page 1-3)).
Observe the following conditions of temperature
and time of soldering.
Temperature of soldering iron : 350
and time of soldering.
Temperature of soldering iron : 350
°
Time of contacting the soldering : 3 seconds
iron with the solder
iron with the solder
The laser diode may suffer electrostatic breakdown
because of the potential difference generated by the
charged electrostatic load, etc. on clothing and the
human body.
During repair, pay attention to electrostatic breakdown
and also use the procedure in the printed matter which
is included in the repair parts.
because of the potential difference generated by the
charged electrostatic load, etc. on clothing and the
human body.
During repair, pay attention to electrostatic breakdown
and also use the procedure in the printed matter which
is included in the repair parts.
The flexible board is easily damaged and should be
handled with care.
handled with care.
9
Laser unit
8
Three solderings
2-17
DCR-PC330/PC330E
2-23.CD-452 BOARD, LENS DEVICE LSV-870A
1
FK flexible
fixed sheet
2
CD shield
sheet (A)
3
Tapping screw
(M1.7
×
5) (silver)
4
CD heat sink,
CD radiation sheet,
MD flexible guard sheet, etc.
MD flexible guard sheet, etc.
(CD heat sink)
(CD radiation sheet)
(CD radiation sheet (small))
(MD flexible guard sheet)
5
CDF sheet
6
BB retainer cushion (A)
7
Two tapping screws
(M1.7
×
5) (silver)
8
Lens device LSV-870A
9
Optical filter block
(OFB-04-30)
q;
Seal rubber (870)
qa
Remove the
solderings
qs
CCD block
assembly
qd
CD-452
board
CD radiation sheet
(L)(large)
(L)(large)
2-24.GMR (M) SENSOR
1
Screw (M1.4
×
3.5)
5
Screw
(M1.4
×
3.5)
4
GMR (M) sensor
8
GMR (M) sensor
2
MR spacer (760)
6
MR spacer (760)
3
Remove the
four solderings
7
Remove the
four solderings
Be careful not to drop
the MR spacer (760).
the MR spacer (760).
Be careful not to drop
the MR spacer (760).
the MR spacer (760).
Caution
Caution
Click on the first or last page to see other DCR-PC330 / DCR-PC330E (serv.man2) service manuals if exist.