DOWNLOAD Sony DCR-HC90 / DCR-HC90E (serv.man4) Service Manual ↓ Size: 989.95 KB | Pages: 70 in PDF or view online for FREE

Model
DCR-HC90 DCR-HC90E (serv.man4)
Pages
70
Size
989.95 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc90-dcr-hc90e-sm4.pdf
Date

Sony DCR-HC90 / DCR-HC90E (serv.man4) Service Manual ▷ View online

6-14
DCR-HC90/HC90E
5. 18 Page Table
Note1: When reading or writing the 18 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 18 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”.)
Table. 6-1-9.
6. 1C Page Table
Note1: When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”.)
Note3: When checking the 3 page data, the data of page: 0, address: 10
must be “00”.
Address
00
01
02 to D7
D8
D9 to DF
E0
E1 to E3
E4
E5 to F1
F2
F3 to F6
F7
F8 to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
00 to 77
78
79 to A9
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
00
00
00
00
00
80
00
00
00
00
00
Fixed data-1
Fixed data-2
Fixed data-1
Error rate check
Address
Remark
Initial value
Address
Remark
Initial value
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9 to D4
D5
D6 to E5
E6
E7
E8
E9
EA
EB
EC
ED to EE
EF
F0
F1 to F3
F4
F5
F6
F7
F8
F9
FA to FF
00
00
00
00
00
80
00
00
00
00
00
Error rate check
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2 (Modified data. Copy
the data built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Table. 6-1-10.
6-15
DCR-HC90/HC90E
1-2-3.
INITIALIZATION OF E, F, 14, 19, 1E, 1F PAGE
DATA
Note: When reading or writing the E, F page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 14, 19, 1E and 1F page data, select
page: 0, address: 10, and set data: 01, then select 4, 9, E or F page.
The 14, 19, 1E or 1F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the E, F, 14, 19, 1E, 1F Page Data
Note1: If “Initializing the E, F, 14, 19, 1E, 1F Page Data” is performed,
all data of the E page, F page, 14 page, 19 page, 1E page and 1F
page will be initialized. (It is impossible to initialize a single page.)
Note2: If the E, F, 14, 19, 1E, 1F page data has been initialized, following
adjustments need to be performed again.
1) Modification of E, F, 14, 19, 1E, 1F page data
2) Camera system adjustments
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
14
Adjusting Address
00 to FF
Adjusting page
19
Adjusting Address
00 to FF
Adjusting page
1E
Adjusting Address
00 to FF
Adjusting page
1F
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
Set the following data, and press
PAUSE button.
2D: DCR-HC90 (NTSC)
2F: DCR-HC90E (PAL)
4
6
03
03
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”.
6
6
01
00
Set the data, and press PAUSE
button.
7
Perform “Modification of E, F,
14, 19, 1E, 1F Page Data”.
2. Modification of E, F, 14, 19, 1E, 1F Page Data
If the E, F, 14, 19, 1E, 1F page data has been initialized, change the
data of the “Fixed data-2” address shown in the following table by
manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the E, F page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 14, 19, 1E, 1F page data, select page: 0,
address: 10, and set data: 01.
After completing the modification of 14, 19, 1E, 1F page data,
reset the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 14, 19, 1E, 1F Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
6-16
DCR-HC90/HC90E
3. E Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
14, 19, 1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
14, 19, 1E, 1F Page Data”.)
4. F Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
14, 19, 1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
14, 19, 1E, 1F Page Data”.)
Address
00 to 04
05
06 to 07
08
09
0A
0B
0C to 0D
0E
0F
10
11 to 12
13
14 to 1A
1B
1C to 1F
20
21
22
23
24 to 37
38
39
3A to 3B
3C
3D
3E
3F
40 to 66
67
68
69
6A to 71
72
73
74 to A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD to FF
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Table. 6-1-11.
Initial value
NTSC PAL
Address
Remark
Initial value
00 to 0F
10
11 to 12
13
14
15
16
17
18
19
1A
1B
1C to 23
24
25
26
27
28 to 29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36 to 3D
3E
3F
40 to 43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
40
28
70
40
80
19
28
D8
28
D8
00
30
B4
1A
00
07
00
11
00
0A
00
2D
64
2D
80
5A
40
11
C9
4C
52
23
92
00
00
00
00
69
19
19
40
28
70
40
80
19
28
D8
28
D8
00
30
D0
1A
00
07
00
11
00
0A
00
2D
64
2D
10
59
70
11
C9
4C
52
23
92
00
00
00
00
69
19
19
Origin osc. Adj.
Fixed data-1
HALL adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
LV standard data input
MAX GAIN adj.
Fixed data-1
AWB standard data input
Auto white balance adj.
Fixed data-1
Strobe white balance adj.
Fixed data-1
Auto white balance adj.
Flange back adj.
6-17
DCR-HC90/HC90E
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
61
62
63
64
65
66 to 71
72
73
74 to 75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92 to AC
AD
AE
AF to BA
BB
BC to BF
C0
26
00
06
00
80
80
80
80
40
C0
40
C0
40
C0
40
C0
C6
00
86
00
66
00
50
00
40
00
50
5D
58
4E
3E
20
80
80
80
80
80
80
04
80
80
80
80
20
26
00
06
00
80
80
80
80
40
C0
40
C0
40
C0
40
C0
A4
00
70
00
56
00
43
00
35
00
50
5D
58
4B
3A
20
80
80
80
80
80
80
04
80
80
80
80
20
Flange back adj.
MR adj./Flange back adj.
Fixed data-1
MR adj.
Fixed data-1
Fixed data-2
Fixed data-1
Mechanical shutter adj.
Strobe light level adj.
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Initial value
NTSC PAL
Address
Remark
Initial value
C1
C2
C3
C4 to D5
D6
D7
D8 to FF
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Initial value
NTSC PAL
Address
Remark
Table. 6-1-12.
5. 14 Page Table
Note1: When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
14, 19, 1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
14, 19, 1E, 1F Page Data”.)
Address
Remark
Initial value
00 to 68
69
6A
6B
6C
6D
6E
6F
70 to 97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
00
00
00
00
00
00
00
00
F5
EE
3A
2C
03
FE
35
38
00
00
00
00
00
00
00
00
00
00
00
00
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Mixed color compensation adj.
Color reproduction adj.
Mixed color compensation adj.
F page
Page of 70
Display

Click on the first or last page to see other DCR-HC90 / DCR-HC90E (serv.man4) service manuals if exist.