DOWNLOAD Sony DCR-HC90 / DCR-HC90E (serv.man4) Service Manual ↓ Size: 989.95 KB | Pages: 70 in PDF or view online for FREE

Model
DCR-HC90 DCR-HC90E (serv.man4)
Pages
70
Size
989.95 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc90-dcr-hc90e-sm4.pdf
Date

Sony DCR-HC90 / DCR-HC90E (serv.man4) Service Manual ▷ View online

6-30
DCR-HC90/HC90E
12. Auto White Balance Standard Data Input
Adjust the white balance reference at 3200K.
Subject
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens) (Note4)
Adjustment Page
F
14 (Note2)
Adjustment Address
2E to 31
E8 to F3
Note1: This adjustment should be carried out upon completion of “Picture
Frame Setting (All White Frame)”.
Note2: When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: Perform  “11. Picture Frame Setting (All White Frame)” before
this adjustment.
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
WIDE (4:3/16:9) ................................................................ 4:3
4)
FOCUS (CAMERA SET menu) ........................... MANUAL
5)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
6)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame is
“All white frame”. If not,
perform “11. Picture Frame
Setting (All White Frame)”.
2
0
01
01
Set the data.
3
0
10
00
Set the data.
4
Wait for more than 2 sec.
5
6
01
43
Set the data, and press PAUSE
button.
6
6
01
41
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“01”. (Note5)
Note5: The adjustment data will be automatically input to page: F, address:
2E to 31 and to page: 14, address: E8 to F3
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
0
01
00
Set the data.
4
Perform “LV Standard Data
Input”.
5
If finishing the camera system
adjustments, perform “Processing
after Completing Adjustments” of
“11. Picture Frame Setting (All
White Frame)”.
13. LV Standard Data Input
Adjust the normal coefficient of the light value.
Subject
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens) (Note4)
Measurement Point
Display data of page 1 (Note5)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
2A, 2B
Specified Value
0FE0 to 1020
Note1: This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: Perform  “11. Picture Frame Setting (All White Frame)” before
this adjustment.
Note5: Displayed data of the adjustment remote commander.
1 : XX : XX
    Display data
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
WIDE (4:3/16:9) ................................................................ 4:3
4)
FOCUS (CAMERA SET menu) ........................... MANUAL
5)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
6)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame is
“All white frame”. If not,
perform “11. Picture Frame
Setting (All White Frame)”.
2
0
01
01
Set the data.
3
6
C9
10
Set the data.
4
Wait for more than 6 sec.
5
6
01
0D
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01” within 20 sec. (Note6)
7
0
03
1E
Set the data.
8
1
Check that the display data
(Note5) satisfies the specified
value.
Note6: The adjustment data will be automatically input to page: F, address:
2A, 2B.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
C9
00
Set the data.
3
0
03
00
Set the data.
4
0
01
00
Set the data.
5
Perform “Auto White Balance
Adjustment”.
6
If finishing the camera system
adjustments, perform “Processing
after Completing Adjustments” of
“11. Picture Frame Setting (All
White Frame)”.
6-31
DCR-HC90/HC90E
14. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens) (Note3)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
14 (Note2)
Adjustment Address
32 to 35, 44 to 47
F4 to FF
Note1: This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note2: When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note3: Perform  “11. Picture Frame Setting (All White Frame)” before
this adjustment.
Note4: NTSC model :DCR-HC90
PAL model    :DCR-HC90E
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
WIDE (4:3/16:9) ................................................................ 4:3
4)
FOCUS (CAMERA SET menu) ........................... MANUAL
5)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
6)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
Place the C14 filter for color
temperature correction on the
lens.
2
Check that the picture frame is
“All white frame”. If not,
perform “11. Picture Frame
Setting (All White Frame)”.
3
0
01
01
Set the data.
4
Wait for more than 2 sec.
5
0
10
00
Set the data.
6
F
44
2D
Set the data, and press PAUSE
button.
7
F
45
Set the following data, and press
PAUSE button.
80 (NTSC), 10 (PAL)
8
F
46
Set the following data, and press
PAUSE button.
5A (NTSC), 59 (PAL)
9
F
47
Set the following data, and press
PAUSE button.
40 (NTSC), 70 (PAL)
10
6
01
47
Set the data, and press PAUSE
button.
11
6
01
45
Set the data, and press PAUSE
button.
12
6
02
Check that the data changes to
“01”. (Note5)
Note5: The adjustment data will be automatically input to page: F, address:
32 to 35, 44 to 47 and to page: 14, address: F4 to FF
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
90
00
Set the data.
3
6
91
00
Set the data.
4
6
92
00
Set the data.
5
6
93
00
Set the data.
6
6
01
00
Set the data, and press PAUSE
button.
7
0
01
00
Set the data.
8
Remove the C14 filter.
Note6: If finishing the camera system adjustments, reset the WIDE (4:3/
16:9) switch to “19:6”.
6-32
DCR-HC90/HC90E
15. Color Reproduction Adjustment
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment
frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens)
Adjustment Page
14 (Note1)
Adjustment Address
A0 to A7
Note1: When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2: NTSC model :DCR-HC90
PAL model    :DCR-HC90E
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
WIDE (4:3/16:9) ................................................................ 4:3
4)
FOCUS (CAMERA SET menu) ........................... MANUAL
5)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
6)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Picture frame setting:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
1F
10
Set the data.
3
6
90
XL
Set the data. (Note3)
4
6
91
XH
Set the data. (Note3)
5
6
92
YL
Set the data. (Note3)
6
6
93
YH
Set the data. (Note3)
7
6
01
79
Set the data, and press PAUSE
button.
8
Check that the picture frame
becomes “Color reproduction
adjustment frame”.
(Refer to “9. Picture Frame
Setting (Color Reproduction
Adjustment Frame)”.)
Note3: XL, XH, YL and YH are the data read in the “9. Picture Frame
Setting (Color Reproduction Adjustment Frame)”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
1F
10
Set the data.
4
6
C9
10
Set the data.
5
6
9E
00
Set the data.
6
6
9D
Set the following data.
38 (NTSC), 30 (PAL)
7
6
01
61
Set the data, and press PAUSE
button.
8
6
02
Check that the data is “01”.
(Note4)
Note4: The adjustment data will be automatically input to page: 14,
address: A0 to A7
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
01
00
Set the data.
2
0
10
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
6
9D
00
Set the data.
5
6
C9
00
Set the data.
6
Perform “Color Reproduction
Check”.
6-33
DCR-HC90/HC90E
16. Color Reproduction Check
Subject
Color bar chart
(Color reproduction adjustment
frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens)
Measurement Point
Video terminal of AUDIO/VIDEO
jack
Measuring Instrument
Vectorscope
Specified Value
Fig. 6-1-15.
Note1: The data of page: 0, address: 10 must be “00”.
Note2: NTSC model :DCR-HC90
PAL model    :DCR-HC90E
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
WIDE (4:3/16:9) ................................................................ 4:3
4)
FOCUS (CAMERA SET menu) ........................... MANUAL
5)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
6)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Picture frame setting:
Order Page Address Data
Procedure
1
6
1F
10
Set the data.
2
6
90
XL
Set the data. (Note3)
3
6
91
XH
Set the data. (Note3)
4
6
92
YL
Set the data. (Note3)
5
6
93
YH
Set the data. (Note3)
6
6
01
79
Set the data, and press PAUSE
button.
7
Check that the picture frame
becomes “Color reproduction
adjustment frame”.
(Refer to “9. Picture Frame
Setting (Color Reproduction
Adjustment Frame)”.)
Note3: XL, XH, YL and YH are the data read in the “9. Picture Frame
Setting (Color Reproduction Adjustment Frame)”.
Checking method:
Order Page Address Data
Procedure
1
6
1F
10
Set the data.
2
6
C9
10
Set the data.
3
6
9E
00
Set the data.
4
6
9D
Set the following data.
38 (NTSC), 30 (PAL)
5
6
01
4D
Set the data, and press PAUSE
button.
6
6
02
Check that the data is “01”.
7
Adjust the GAIN and PHASE of
the vectorscope so that the burst
luminance point is set at the
specified position.
8
Check that each center of all
color luminance points is set in
each color reproduction frame.
For NTSC model
For PAL model
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
1F
00
Set the data.
3
6
90
00
Set the data.
4
6
91
00
Set the data.
5
6
92
00
Set the data.
6
6
93
00
Set the data.
7
6
9D
00
Set the data.
8
6
C9
00
Set the data.
Note4: If finishing the camera system adjustments, reset the WIDE (4:3/
16:9) switch to “19:6”.
Fig. 6-1-15.
Burst position
Burst position
Page of 70
Display