DOWNLOAD Sony DCR-HC90 / DCR-HC90E (serv.man4) Service Manual ↓ Size: 989.95 KB | Pages: 70 in PDF or view online for FREE

Model
DCR-HC90 DCR-HC90E (serv.man4)
Pages
70
Size
989.95 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc90-dcr-hc90e-sm4.pdf
Date

Sony DCR-HC90 / DCR-HC90E (serv.man4) Service Manual ▷ View online

6-10
DCR-HC90/HC90E
3. A Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”.)
Table. 6-1-2.
4. B Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”.)
Table. 6-1-3.
Initial value
NTSC PAL
00 to 0F
10
11 to 17
18
19 to 2E
2F
30
31
31 to 5F
60
61
62
63
64 to 8F
90
91
92
93
94 to CF
D0
D1
D2
D3 to D4
D5
D6
D7
D8
D9
DA to F1
F2
F3 to FF
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Touch panel adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
Remark
Initial value
00
E8
13
C7
30
00
E4
16
D2
21
5. D Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”.)
Address
00 to FF
Remark
Fixed data-1
Address
00 to 0F
10 to 13
14
15
16
17 to 27
28
29
2A
2B
2C
2D
2E
2F
30
31 to 32
33
34 to 44
45
46 to 47
48
49
4A
4B
4C
4D
4E
4F
50 to 56
57
58 to 7F
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-4.
6. 1A Page Table
Note1: When reading or writing the 1A page data, select page: 0, address:
10, and set data: 01, then select A page. The 1A page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”.)
Table. 6-1-5.
7. 1B Page Table
Note1: When reading or writing the 1B page data, select page: 0, address:
10, and set data: 01, then select B page. The 1B page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the A, B,
D, 1A, 1B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of A, B,
D, 1A, 1B Page Data”.)
Table. 6-1-6.
Address
00 to FF
Remark
Fixed data-1
Address
00 to FF
Remark
Fixed data-1
6-11
DCR-HC90/HC90E
1-2-2.
INITIALIZATION OF 8, C, 18, 1C PAGE DATA
Note: When reading or writing the 8, C page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 18, 1C page data, select page: 0, address:
10, and set data: 01, then select 8 or C page. The 18 or 1C page can
be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the 8, C, 18, 1C Page Data
Note1: If “Initializing the 8, C, 18, 1C Page Data” is performed, all data
of the 8 page, C page, 18 page and 1C page will be initialized. (It
is impossible to initialize a single page.)
Note2: If the 8, C, 18, 1C page data has been initialized, following
adjustments need to be performed again.
1) Modification of 8, C, 18, 1C page data
2) Viewfinder system adjustments
3) LCD system adjustments
4) Serial No. input
5) Servo and RF system adjustments
6) Video system adjustments
Adjusting page
8
Adjusting Address
00 to FF
Adjusting page
C
Adjusting Address
10 to FF
Adjusting page
18
Adjusting Address
00 to FF
Adjusting page
1C
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
3
81
Check that the data is “00”.
4
3
80
0C
Set the data, and press PAUSE
button.
5
3
80
Check that the data changes to
“1C”.
6
Perform “Modification of 8, C,
18, 1C Page Data”.
2. Modification of 8, C, 18, 1C Page Data
If the 8, C, 18, 1C page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the 8, C page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 18, 1C page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 18, 1C page data, reset
the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of 8, C, 18, 1C Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
6-12
DCR-HC90/HC90E
3. 8 Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”.)
Table. 6-1-7.
4. C Page Table
Note1: The data of page: 0, address: 10 must be “00”.
Note2: Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”.)
Address
00 to 18
19
1A to 29
2A
2B to 3F
40
41
42
43
44
45
46 to 4C
4D
4E to 79
7A
7B
7C to 81
82
83
84
85
86
87
88
89
8A to 8D
8E
8F
90 to 99
9A
9B to AB
AC
AD to B2
B3
B4 to B5
B6
B7
B8
B9
BA
BB
BC to BD
BE
BF
C0 to C2
C3
C4
C5
C6
C7
C8
C9
CA
Remark
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Remark
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Address
CB
CC
CD
CE to D5
D6
D7
D8 to DF
E0
E1
E2
E3
E4
E5
E6
E7
E8 to EF
F0
F1 to F9
FA
FB
FC to FF
Initial value
NTSC PAL
00 to 0F
10
11
12
13
14 to 15
16
17 to 24
25
26
27
28 to 3B
3C
3D
3E
3F
40
41
42
43
44
45
46
47
48
49 to 4B
4C
Switching position adj.
Fixed data-1
CAP FG duty adj.
Fixed data-1
S VIDEO out Y level adj.
S VIDEO out chroma level adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
VCO adj. (EVF)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
White balance adj. (EVF)
Contrast adj. (EVF)
Fixed data-2
Fixed data-1
Fixed data-2
Address
Remark
Initial value
EE
00
00
00
E0
81
80
60
7A
80
82
79
58
EE
00
00
00
E0
80
80
60
6C
90
82
79
58
6-13
DCR-HC90/HC90E
Initial value
NTSC PAL
Address
Remark
Initial value
4D
4E
4F
50
51
52
53 to 54
55
56
57
58
59 to 5B
5C
5D
5E
5F
60 to 61
62
63
64 to 65
66
67
68
69 to 6A
6B
6C to 74
75
76 to 78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B to 90
91
92
93
94
95
96
97 to 98
99
9A to A0
6C
90
B8
80
80
4C
7A
75
80
BA
85
00
00
00
00
33
D2
A8
23
80
78
80
B8
80
80
4C
7A
75
80
CD
92
00
00
00
00
33
D2
A8
23
80
Fixed data-2
(Modified data. Copy the data
built in the same model.)
VCO adj. (LCD)
V COM adj. (LCD)
Fixed data-1
Fixed data-2
Transmissive mode white balance
adj. (LCD)
Contrast adj. (LCD)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Reflective mode white balance adj.
(LCD)
Fixed data-1
Fixed data-2
Fixed data-1
IC4701 LINE OUT Y level adj.
IC4701 LINE OUT chroma level adj.
IC4701 automatic adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
IC4701 automatic adj.
Fixed data-1
A1
A2
A3
A4
A5 to A8
A9
AA
AB
AC
AD to AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB to CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5 to DD
DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8 to F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
1F
1F
1F
08
00
46
01
02
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
19
19
19
08
00
46
01
02
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
IC4701 automatic adj.
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Serial No. input
Fixed data-1
Emergency memory address
(Mechanism section)
Initial value
NTSC PAL
Address
Remark
Initial value
C page
Table. 6-1-8.
Page of 70
Display