DOWNLOAD Sony DCR-HC65 (serv.man4) Service Manual ↓ Size: 1.07 MB | Pages: 65 in PDF or view online for FREE

Model
DCR-HC65 (serv.man4)
Pages
65
Size
1.07 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc65-sm4.pdf
Date

Sony DCR-HC65 (serv.man4) Service Manual ▷ View online

6-14
DCR-HC65
6. 1C Page Table
Note1:
When reading or writing the 1C page data, select page: 0, address:
10, and set data: 01, then select C page. The 1C page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”).
Note3:
When checking the 3 page data, the data of page: 0, address: 10
must be “00”.
5. 18 Page Table
Note1:
When reading or writing the 18 page data, select page: 0, address:
10, and set data: 01, then select 8 page. The 18 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the 8, C,
18, 1C Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of 8, C,
18, 1C Page Data”).
Table. 6-1-9.
Address
00  to FF
Remark
Fixed data-1
Address
Remark
Initial value
Address
Remark
Initial value
00 to 2E
2F
30 to 77
78
79 to A9
AA
AB to B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9 to FF
0C
04
00
00
00
00
00
80
00
00
00
00
00
00
00
00
00
00
80
00
00
00
00
00
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
When the data of page: 3,
address: F0 is “30”. Note3
When the data of page: 3,
address: F0 is “40”. Note3
(This data vary according to the type
of the IC6401 of VC-359 board.)
Fixed data-1
Error rate check
Fixed data-1
Table. 6-1-10.
6-15
DCR-HC65
1-2-4.
INITIALIZATION OF E, F, 14, 19, 1E, 1F PAGE DATA
Note:
When reading or writing the E, F page data, select page: 0, address:
10, and set data: 00.
When reading or writing the 14, 19, 1E and 1F page data, select
page: 0, address: 10, and set data: 01, then select 4, 9, E or F page.
The 14, 19, 1E or 1F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the E, F, 14, 19, 1E, 1F Page Data
Note1:
If “Initializing the E, F, 14, 19, 1E, 1F Page Data” is performed,
all data of the E page, F page, 14 page, 19 page, 1E page and 1F
page will be initialized. (It is impossible to initialize a single page.)
Note2:
If the E, F, 14, 19, 1E, 1F page data has been initialized, following
adjustments need to be performed again.
1) Modification of E, F, 14, 19, 1E, 1F page data
2) Camera system adjustments
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
14
Adjusting Address
00 to FF
Adjusting page
19
Adjusting Address
00 to FF
Adjusting page
1E
Adjusting Address
00 to FF
Adjusting page
1F
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
2D
Set the data, and press PAUSE
button.
4
6
03
01
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”.
6
6
01
00
Set the data, and press PAUSE
button.
7
Perform “Modification of E, F,
14, 19, 1E, 1F Page Data”.
2. Modification of E, F, 14, 19, 1E, 1F Page Data
If the E, F, 14, 19, 1E, 1F page data has been initialized, change the
data of the “Fixed data-2” address shown in the following table by
manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the E, F page data, select page: 0, address: 10,
and set data: 00.
3)
When changing the 1F page data, select page: 0, address: 10,
and set data: 01.
After completing the modification of 1F page data, reset the
data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F, 14, 19, 1E,
1F Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
6-16
DCR-HC65
3. E Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
14, 19, 1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
14, 19, 1E, 1F Page Data”).
Table. 6-1-11.
Address
00 to 07
08
09
0A
0B
0C
0D
0E
0F
10
11 to 12
13
14 to 1A
1B
1C
1D
1E
1F
20
21
22
23
24
25
26
27
28 to 37
38
39
3A to 3B
3C
3D
3E
3F
40
41
42 to 43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
Remark
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Address
51
52
53
54
55
56 to 59
5A
5B
5C
5D
5E
5F
60 to 61
62
63
64 to 65
66
67
68
69
6A to 6E
6F
70
71
72
73
74 to 86
87
88 to B9
BA
BB to DD
DE
DF to FC
FD
FE
FF
Remark
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
6-17
DCR-HC65
4. F Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F,
14, 19, 1E, 1F Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F,
14, 19, 1E, 1F Page Data”).
Address
Remark
Initial value
Address
Remark
Initial value
00 to 0F
10 to 12
13
14
15
16
17
18
19
1A
1B
1C to 2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A to 3F
40
41
42 to 43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
28
70
88
40
80
88
CC
00
30
25
00
07
00
15
00
0C
00
45
2C
FF
E7
2C
40
5B
80
2E
F8
37
46
1C
54
00
00
00
00
93
19
00
52
00
00
00
80
80
Fixed data-1
HALL adj.
MAX GAIN adj.
LV standard data input
Fixed data-1
AWB standard data input
Auto white balance adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Color reproduction adj.
Fixed data-1
Auto white balance adj.
Flange back adj.
Fixed data-1
MR adj.
Address
Remark
Initial value
Address
Remark
Initial value
5C
5D
5E
5F
60
61
62
63
64
65
66 to 71
72
73
74 to 75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C to 91
92
93 to 9E
9F
A0
A1
A2 to A7
A8
A9 to B0
B1
B2 to D5
D6
D7 to F0
F1
F2 to F7
F8
F9
FA
FB
FC to FF
80
80
40
C0
40
C0
40
C0
40
C0
40
00
34
00
30
00
2A
00
10
00
40
3A
31
31
35
1E
80
80
80
80
80
80
19
MR adj.
Fixed data-1
Fixed data-2
Fixed data-1
Mechanical shutter adj.
Fixed data-1
HALL adj.
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
(Modified data. Copy the data
built in the same model.)
Fixed data-1
Table. 6-1-12.
Page of 65
Display

Click on the first or last page to see other DCR-HC65 (serv.man4) service manuals if exist.