Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc65-sm4.pdf
Date

Sony DCR-HC65 (serv.man4) Service Manual ▷ View online

6-22
DCR-HC65
2. HALL Adjustment
For detecting the position of the lens iris and ND filter, adjust AMP
gain and offset.
Subject
Not required
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
19 (Note2)
Adjustment Address
13 to 18, 92
24 to 27
Specified Value 1
D4 to DC
Specified Value 2
24 to 2C
Specified Value 3
D2 to DE
Specified Value 4
22 to 2E
Note1:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
IRIS display data
ND display data
Note2:
When reading or writing the 19 page data, select page: 0, address:
10, and set data: 01, then select 9 page. The 19 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Switch setting:
MODE ......................................................... CAMERA-TAPE
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
6D
Set the data, and press PAUSE
button.
4
6
02
Check that the data changes to
“01” within 50 sec. (Note3)
5
6
01
00
Set the data, and press PAUSE
button.
Note3:
The adjustment data will be automatically input to page: F, address:
13 to 18, 92 and to page: 19, address: 24 to 27.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
Set the data.
2
0
10
00
Set the data.
3
6
01
01
Set the data, and press PAUSE
button.
4
6
01
03
Set the data, and press PAUSE
button.
5
1
Check that the IRIS display data
(Note1) satisfies the specified
value 1.
6
6
01
01
Set the data, and press PAUSE
button.
7
1
Check that the IRIS display data
(Note1) satisfies the specified
value.2.
8
6
01
6B
Set the data, and press PAUSE
button.
9
6
01
69
Set the data, and press PAUSE
button.
10
1
Check that the ND display data
(Note1) satisfies the specified
value 3.
11
6
01
6B
Set the data, and press PAUSE
button.
12
1
Check that the ND display data
(Note1) satisfies the specified
value.4.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
03
00
Set the data.
2
0
10
00
Set the data.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
6-23
DCR-HC65
3. MR Adjustment
The MR (Magnet resistor) adjustment of the inner focus lens is
carried out automatically. In whichever case, the focus will be
deviated during auto focusing/manual focusing.
Subject
Not required
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
58, 5A to 65
Specified Value1
40 to C0
Specified Value2
03 to 78
Specified Value3
88 to FD
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
Perform this adjustment before “Flange Back Adjustment”.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
MODE ......................................................... CAMERA-TAPE
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
BD
Set the data, and press PAUSE
button.
3
6
02
Check that the data changes to
“01”. (Note5)
4
F
5A
Check that the data satisfies the
specified value 1.
5
F
5B
Check that the data satisfies the
specified value 1.
6
F
5C
Check that the data satisfies the
specified value 1.
7
F
5D
Check that the data satisfies the
specified value 1.
8
F
5E
Check that the data satisfies the
specified value 2.
9
F
5F
Check that the data satisfies the
specified value 3.
10
F
60
Check that the data satisfies the
specified value 2.
11
F
61
Check that the data satisfies the
specified value 3.
12
F
62
Check that the data satisfies the
specified value 2.
13
F
63
Check that the data satisfies the
specified value 3.
14
F
64
Check that the data satisfies the
specified value 2.
15
F
65
Check that the data satisfies the
specified value 3.
Note5:
The adjustment data will be automatically input to page: F, address:
58, 5A to 65.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Turn off the power and turn on
again
6-24
DCR-HC65
4. Flange Back Adjustment
(Using Minipattern Box)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
Subject
Siemens star chart with ND filter for
the minipattern box (Note1)
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
48 to 58
Specified Value
Data of page: F, address: 57 is “00” to “0B”.
Data of page: 6, address: 0C is “00”.
Note1:
Dark Siemens star chart.
Note2:
This adjustment should be carried out upon completion of the
following adjustments.
“HALL Adjustment”, “MR Adjustment”
Note3:
Make the lens horizontal and perform this adjustment.
Note4:
The data of page: 0, address: 10 must be “00”.
Note5:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
MODE ......................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
COLOR SLOW SHUTTER (CAMERA SET menu) ...... OFF
Preparations:
1)
The minipattern box is installed as shown in the following
figure.
Note:
The attachment lenses are not used.
2)
Install the minipattern box so that the distance between it and
the front of the lens of the camcorder is less than 3cm.
3)
Make the height of the minipattern box and the camcorder equal.
4)
Check that the output voltage of the regulated power supply is
the specified voltage.
5)
Check that at both the zoom lens TELE end and WIDE end,
the center of the Siemens star chart and center of the exposure
screen coincide.
Specified voltage:
The specified voltage varies according to the minipattern box, so
adjust the power supply output voltage to the specified voltage
written on the sheet which is supplied with the minipattern box.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button.
3
Wait for 1 sec.
4
6
01
27
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note6)
6
F
57
Check that the data is “00” to
“0B”.
7
6
0C
Check that the data is “00”.
Note6:
The adjustment data will be automatically input to page: F, address:
48 to 58.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
01
25
Set the data, and press PAUSE
button.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
5
Perform “Flange Back Check”.
Minipattern box
Below 3 cm
Camcorder
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
0.01Vdc
Output current : more than 3.5A
Fig. 6-1-7.
6-25
DCR-HC65
5. Flange Back Adjustment
(Using Flange Back Adjustment Chart and Subject
More Than 500m Away)
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
5-1. Flange Back Adjustment (1)
Subject
Flange back adjustment chart
(2.0 m from the front of the protection
glass) (Luminance: 350 ± 50 lux)
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
48 to 58
Specified Value
Data of page: F, address: 57 is “00” to “0B”.
Data of page: 6, address: 0C is “00”.
Note1:
This adjustment should be carried out upon completion of the
following adjustments.
“HALL Adjustment”, “MR Adjustment”
Note2:
Make the lens horizontal and perform this adjustment.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
MODE ......................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
COLOR SLOW SHUTTER (CAMERA SET menu) ...... OFF
Preparations:
1)
Check that at both the zoom lens TELE end and WIDE end,
the center of the chart for the flange back adjustment and center
of the exposure screen coincide.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button.
3
Wait for 1 sec.
4
6
01
15
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note5)
6
F
57
Check the data is “00” to “0B”.
7
6
0C
Check that the data is “00”.
Note5:
The adjustment data will be automatically input to page: F, address:
48 to 58.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
01
25
Set the data, and press PAUSE
button.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
5
Perform “Flange Back
Adjustment (2)”
5-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment (1)”.
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
48 to 58
Note1:
Make the lens horizontal and perform this adjustment.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
MODE ......................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
COLOR SLOW SHUTTER (CAMERA SET menu) ...... OFF
Preparations:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500m away should
not be in the screen.)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
01
13
Set the data, and press PAUSE
button.
3
Wait for 1 sec.
4
Place a ND filter on the lens so
that the optimum image is obtain.
5
6
01
29
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: F, address:
48 to 58.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
01
25
Set the data, and press PAUSE
button.
3
6
01
00
Set the data, and press PAUSE
button.
4
0
01
00
Set the data.
5
Perform “Flange Back Check”
Page of 65