Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc65-sm4.pdf
Date

Sony DCR-HC65 (serv.man4) Service Manual ▷ View online

6-30
DCR-HC65
11. Picture Frame Setting (All White Frame)
When performing “Auto White Balance Standard Data Input”, “LV
Standard Data Input”, “Auto White Balance Adjustment” and “White
Balance Check”, set the picture frame to “All white frame”.
Subject
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens)
Measurement Point
Video terminal of AUDIO/VIDEO jack
Measuring Instrument
TV monitor (Under scan mode)
Specified Value
Whole of the screen is white
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
XL or YL data
XH or YH data
Switch setting:
1)
MODE ......................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Setting method:
Order Page Address Data
Procedure
1
While observing the TV monitor
screen, adjust the zoom to TELE
side from WIDE side, and stop it
when the black frame of the chart
disappears.
2
Check that whole of the screen is
white.
3
0
03
18
Set the data.
4
1
Read the XH and XL data. (Note2)
5
0
03
22
Set the data.
6
1
Read the YH and YL data. (Note2)
7
0
03
00
Set the data.
8
Perform the following adjustments.
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason reset them in the
following method.
Order Page Address Data
Procedure
1
6
90
XL
Set the data.
2
6
91
XH
Set the data.
3
6
92
YL
Set the data.
4
6
93
YH
Set the data.
5
6
01
79
Set the data, and press PAUSE
button.
Processing after Completing Adjustments
After completing “Auto White Balance Standard Data Input”, “LV
Standard Data Input”, “Auto White Balance Adjustment” and “White
Balance Check”, release the data setting.
Order Page Address Data
Procedure
1
6
90
00
Set the data.
2
6
91
00
Set the data.
3
6
92
00
Set the data.
4
6
93
00
Set the data.
12. Auto White Balance Standard Data Input
Adjust the white balance reference at 3200K.
Subject
Clear chart (All white frame) (Note2)
Adjustment Page
F
14 (Note3)
Adjustment Address
2E to 31
E8 to F3
Note1:
This adjustment should be carried out upon completion of  “Color
reproduction adjustment”.
Note2:
Perform “11. Picture Frame Setting (All White Frame)” before
this adjustment.
Note3:
When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Note4:
After the power is turned on, this adjustment can be done only
once.
Note5:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
MODE ......................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
Check that the whole of the screen
is white. If not, perform “11.
Picture Frame Setting (All White
Frame)”.
2
0
01
01
Set the data.
3
0
10
00
Set the data.
4
Wait for more than 2 sec.
5
6
01
43
Set the data, and press PAUSE
button.
6
6
01
41
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“01”. (Note6)
Note6:
The adjustment data will be automatically input to page: F, address:
2E to 31 and to page: 14, address: E8 to F3.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
0
01
00
Set the data.
4
Perform “LV Standard Data
Input”.
6-31
DCR-HC65
13. LV Standard Data Input
Adjust the normal coefficient of the light value.
Subject
Clear chart (All white frame) (Note2)
Measurement Point
Display data of page 1 (Note4)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
1A, 1B
Specified Value
0FE0 to 1020
Note1:
This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note2:
Perform  “11. Picture Frame Setting (All White Frame)” before
this adjustment.
Note3:
The data of page: 0, address: 10 must be “00”.
Note4:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note5:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
MODE ......................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
Check that the whole of the screen
is white. If not, perform “11.
Picture Frame Setting (All White
Frame)”.
2
0
01
01
Set the data.
3
Wait for more than 6 sec.
4
6
01
0D
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01” within 20 sec. (Note6)
6
0
03
1E
Set the data.
7
1
Check that the display data
(Note5) satisfies the specified
value.
Note6:
The adjustment data will be automatically input to page: F, address:
1A, 1B.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
03
00
Set the data.
3
0
01
00
Set the data.
4
Perform “Auto White Balance
Adjustment”.
14. Auto White Balance Adjustment
Adjust to the proper auto white balance output data.
If it is not correct, auto white balance and color reproducibility will
be poor.
Subject
Clear chart (All white frame) (Note2)
Filter
Filter C14 for color temperature
correction
Adjustment Page
F
14 (Note3)
Adjustment Address
32 to 35, 44 to 47
F4 to FF
Note1:
This adjustment should be carried out upon completion of “Auto
White Balance Standard Data Input”.
Note2:
Perform “11. Picture Frame Setting (All White Frame)” before
this adjustment.
Note3:
When reading or writing the 14 page data, select page: 0, address:
10, and set data: 01, then select 4 page. The 14 page can be chosen
by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
Switch setting:
1)
MODE ......................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5)
STEADY SHOT (CAMERA SET menu) ........................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
Check that the whole of the screen
is white. If not, perform “11.
Picture Frame Setting (All White
Frame)”.
2
Place the C14 filter for color
temperature correction on the lens.
3
0
01
01
Set the data.
4
0
10
00
Set the data.
5
F
44
2D
Set the data, and press PAUSE
button.
6
F
45
40
Set the data, and press PAUSE
button.
7
F
46
58
Set the data, and press PAUSE
button.
8
F
47
80
Set the data, and press PAUSE
button.
9
6
01
47
Set the data, and press PAUSE
button.
10
6
01
45
Set the data, and press PAUSE
button.
11
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: F, address:
32 to 35 and to page: 14, address: F4 to FF.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
0
01
00
Set the data.
4
Perform “White Balance Check”.
6-32
DCR-HC65
15. White Balance Check
Subject
Clear chart (All white frame)
(1.0m (PTB-450) or 0.4m (PTB-1450)
from the front of the lens) (Note3)
Filter
ND filter 1.0 and 0.4 and 0.1
Measurement Point
Display data of page 1 (Note4)
Measuring Instrument
Adjustment remote commander
Specified Value 1
8000 to FFF0
Specified Value 2
8000 to FFF0
Specified Value 3
8000 to 8BC0
Note1:
Perform “Auto White Balance Adjustment” before this adjustment.
If not performed, the specified value of “Outdoor white balance
check” may not be satisfied.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Perform “11. Picture Frame Setting (All White Frame)”.
Note4:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
MODE ......................................................... CAMERA-TAPE
2)
NIGHT SHOT .................................................................. OFF
3)
FOCUS .................................................................. MANUAL
4)
DIGITAL ZOOM (CAMERA SET menu) ...................... OFF
5)
 STEADY SHOT (CAMERA SET menu) ....................... OFF
Checking method:
Order Page Address Data
Procedure
1
Check that the picture frame is
“All white frame”. If not,
perform “11. Picture Frame
Setting (All White Frame)”.
Outdoor white balance check
2
6
01
4F
Set the data, and press PAUSE
button.
3
0
03
33
Set the data.
4
1
Check that the display data
(Note4) satisfies the specified
value 1. (Note5)
5
6
01
00
Set the data, and press PAUSE
button.
Indoor white balance check
6
6
01
0F
Set the data, and press PAUSE
button.
7
0
03
33
Set the data.
8
1
Check that the display data
(Note4) satisfies the specified
value 2. (Note5)
9
6
01
00
Set the data, and press PAUSE
button.
LV data check
10
Place the ND filter 1.5
(1.0+0.1+0.4) on the lens.
11
0
03
06
Set the data.
12
1
Check that the display data
(Note4) satisfies the specified
value 3.
Note5:
If the specified value is not satisfied. Contents of the error are
displayed at the lower digit (bit0 to bit3) of the display data. (For
the bit values, refer to “6-4. SERVICE MODE”, “4-3. 4. Bit value
discrimination”.)
bit0=1: B-Y data exceeded an upper limit
bit1=1: B-Y data exceeded a lower limit
bit2=1: R-Y data exceeded an upper limit
bit3=1: R-Y data exceeded a lower limit
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
0
03
00
Set the data.
2
6
01
00
Set the data, and press PAUSE
button.
3
6
90
00
Set the data.
4
6
91
00
Set the data.
5
6
92
00
Set the data.
6
6
93
00
Set the data.
7
Remove the ND filter.
6-33
DCR-HC65
16. Steady Shot Check
Precautions on the Parts Replacement
There are two types of repair parts.
Type A : ENC03MA
Type B : ENC03MB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Specified Value
2680 to 5080
Note1:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note2:
The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
STEADY SHOT (CAMERA SET menu) ......................... ON
2)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
Pitch sensor check
(CD-513 board SE401)
1
0
03
11
Set the data.
2
1
Check that the display data
(Note1) satisfies the specified
value. (Note3)
Yaw sensor check
(CD-513 board SE402)
3
0
03
12
Set the data.
4
1
Check that the display data
(Note1) satisfies the specified
value. (Note3)
5
0
03
00
Set the data.
6
Move the camcorder, and check
that the steady shot operations
have been performed normally
Note3:
Don’t move the camcorder.