DOWNLOAD Sony DCR-HC36 / DCR-HC36E (serv.man4) Service Manual ↓ Size: 795.11 KB | Pages: 63 in PDF or view online for FREE

Model
DCR-HC36 DCR-HC36E (serv.man4)
Pages
63
Size
795.11 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc36-dcr-hc36e-sm4.pdf
Date

Sony DCR-HC36 / DCR-HC36E (serv.man4) Service Manual ▷ View online

6-7
DCR-HC36/HC36E_ADJ
H
A=B
C=D
A B
B
C
D
A
Enlargement
V
Electronic beam scanning frame
CRT picture frame
B
A
Difference in level
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Y
ello
w
Cy
an
Green
White
Magenta
Red
Blue
Color bar chart (Color reproduction adjustment frame)
Fig. a
(VIDEO terminal of A/V OUT jack
output waveform)
Fig. b (monitor TV picture)
Adjust the camera zoom and direction to
obtain the output waveform shown in Fig. a and
the monitor TV display shown in Fig. b.
2.
Order of Adjustments
Basically carry out adjustments in the order given.
3.
Subjects
1) Color bar chart (Color reproduction adjustment frame)
When performing adjustments using the color bar chart, ad-
just the picture frame as shown in Fig. 6-1-4. (Color reproduc-
tion adjustment frame)
2) Clear chart (Color reproduction adjustment frame)
Remove the color bar chart from pattern box and insert a clear
chart in its place. (Do not perform zoom operations during
this time.)
3) Chart for flange back adjustment
Join together a piece of white A0 size paper (1189mm ¥ 841
mm) and a piece of black paper to make the chart shown in
Fig. 6-1-5.
Note: Use a non-reflecting and non-glazing vellum paper.  The
size must be A0 or larger and the joint between the white
and black paper must not have any undulations.
Fig. 6-1-5
Black
White
841 mm
1189 mm
1. POWER switch (SS17000 block) ........................... CAMERA
2. NIGHTSHOT PLUS switch (Lens block) ...................... OFF
3. BACK LIGHT (CF17000 block) ..................................... OFF
4. PROGRAM AE (MENU setting) ................................. AUTO
5. EXPOSURE (MENU setting) ...................................... AUTO
6. WHITE BAL. (MENU setting) .................................... AUTO
7. FOCUS (MENU setting) ....................................... MANUAL
Fig. 6-1-4
8. COLOR SLOW S (MENU setting) ................................. OFF
9. DIGITAL ZOOM (MENU setting) ................................. OFF
10. WIDE SELECT (MENU setting) ....................................... 4:3
11. STEADY SHOT (MENU setting) ................................... OFF
12. D EFFECT (MENU setting) ............................................ OFF
13. PICT. EFFECT (MENU setting) ..................................... OFF
14. DEMO MODE (MENU setting) ..................................... OFF
1-1-2.
Precaution
1.
Setting the Switch
Unless otherwise specified, set the switches as follows and perform adjustments without loading cassette.
6-8
DCR-HC36/HC36E_ADJ
4.
Preparing the Flash Adjustment Box
A dark room is required to provide an accurate flash adjustment.
If it is not available, prepare the flash adjustment box as given
below;
1) Provide woody board A, B and C of 15 mm thickness.
2) Apply black mat paint to one side of woody board A and B.
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
side of woody board A, B and C are internal. (Fig. 6-1-7)
Fig. 6-1-6
Fig. 6-1-7
woody board A (2)
400 mm
woody board B (2)
370 mm
woody board C (1)
700 mm
513 mm
513 mm
700 mm
700 mm
730 mm
woody board A
woody board B
woody board B
woody board C
woody board A
6-9
DCR-HC36/HC36E_ADJ
1-2.
INITIALIZATION OF 8, A, B, C, D, E, F, 18, 19,
1A, 1B, 1C, 1E, 1F PAGE DATA
Note: If reading/writing data on pages 18, 19, 1A, 1B, 1C, 1E,
1F, set data: 01 to page: 0, address: 10, and then select
pages: 8, 9, A, B, C, E, F.
By this data setting, the pages 18, 19, 1A, 1B, 1C, 1E,
1F, can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
1-2-1.
Initialization of A, B, D, 1A, 1B Page Data
Note: Check that the data of page: 0, address: 10 is “00”.
1.
Initializing of A, B, D, 1A, 1B Page Data
Note 1: If the A, B, D, 1A, 1B page data has been initialized, the
following adjustments need to be performed again.
1) Modification of A, B, D, 1A, 1B page data
2) Touch panel adjustment
Note 2: NTSC model: DCR-HC36
PAL model: DCR-HC36E
Adjustment Page
A
Adjustment Address
10 to FF
Adjustment Page
B
Adjustment Address
00 to FF
Adjustment Page
D
Adjustment Address
10 to 7F
Adjustment Page
1A
Adjustment Address
00 to FF
Adjustment Page
1B
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
7
04
Set the following data
20: NTSC model
21: PAL model
Set the following data
20: Initializing A page
21: Initializing B page
22: Initializing D page
23: Initializing 1A page
24: Initializing 1B page
4
7
01
25: Initializing A and 1A
pages
26: Initializing B and 1B
pages
28: Initializing A, B, D, 1A
and 1B pages
5
7
00
01
Press PAUSE (Write) button.
6
7
02
Check the data changes to
“01”.
7
Perform “Modification of A,
B, D, 1A, 1B Page Data”
2.
Modification of A, B, D, 1A, 1B Page Data
If the A, B, D, 1A, 1B page data has been initialized, change the
data of the “Fixed data-2” address shown in the following table by
manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages A, B, D, set data: 00 to page:
0, address: 10, and then select pages A, B, D.
3) If modification of data on pages 1A, 1B, set data: 01 to page:
0, address: 10, and then select pages A, B.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note 1: If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification A, B, D, 1A, 1B
page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE (Write) button.
Note 2: If following symptoms occur after completing of the
“Modification A, B, D, 1A, 1B page data”, check that
the data of the “Fixed data-2” address of A, B, D, 1A, 1B
page are same as those of same model of same destina-
tion.
1) The power is shut off so that unit cannot operate.
6-10
DCR-HC36/HC36E_ADJ
4.
B Page table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
5.
D Page table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
10 to 13
Fixed data-1 (Initialized data)
14
Fixed data-2
15
Fixed data-1 (Initialized data)
16
Fixed data-2
17 to 27
Fixed data-1 (Initialized data)
28
29
2A
Fixed data-2
2B
2C
2D
Fixed data-1 (Initialized data)
2E
2F
Fixed data-2
30
31 to 32
Fixed data-1 (Initialized data)
33
34
Fixed data-2
35 to 56
Fixed data-1 (Initialized data)
57
58
Fixed data-2
59
5A to 79
Fixed data-1 (Initialized data)
7A
Fixed data-2
7B to 7F
Fixed data-1 (Initialized data)
3.
A Page table
Note 1: Check that the data of page: 0, address: 10 is“00”.
Note 2: Fixed data-1: Initialized data. (Refer to“1. Initializing the
A, B, D, 1A, 1B Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of A, B, D, 1A, 1B Page Data”)
Address
Initial value
Remark
NTSC PAL
10
00
00
Test mode
11 to 17
Fixed data-1 (Initialized data)
18
Fixed data-2
19 to 2E
Fixed data-1 (Initialized data)
2F
Fixed data-2
30
Fixed data-1 (Initialized data)
31
Fixed data-2
32 to 60
Fixed data-1 (Initialized data)
61
62
Fixed data-2
63
64 to 8F
Fixed data-1 (Initialized data)
90
E8
EB
Touch panel adj.
91
12
10
92
E6
DA
93
16
29
94 to CF
Fixed data-1 (Initialized data)
D0
D1
Fixed data-2
D2
D3, D4
Fixed data-1 (Initialized data)
D5
Fixed data-2
D6
Fixed data-1 (Initialized data)
D7
Fixed data-2
D8
Fixed data-1 (Initialized data)
D9
Fixed data-2
DA to EF
Fixed data-1 (Initialized data)
F0
F1
Fixed data-2
F2
F3 to FF
Fixed data-1 (Initialized data)
Ver. 1.2  2007.12
Page of 63
Display

Click on the first or last page to see other DCR-HC36 / DCR-HC36E (serv.man4) service manuals if exist.