Movie / SECTION 6 ADJUSTMENTS
File
dcr-hc36-dcr-hc36e-sm4.pdf
Date

Sony DCR-HC36 / DCR-HC36E (serv.man4) Service Manual ▷ View online

6-23
DCR-HC36/HC36E_ADJ
4-2. Flange Back Adjustment (2) 
RadarW
RadarW
RadarW
RadarW
RadarW
Perform this adjustment after performing “Flange Back Adjust-
ment (1)”.
Subject
Subject more than 500 m away
(Subject with clear contrast such as
buildings, etc.)
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
44 to 55
Specified value
Data of page: 6, address: 0C is “00”
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
Switch setting:
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) COLOR SLOW S (Menu setting) ................................... OFF
Preparations before adjustments:
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the
screen)
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
13
Press PAUSE (Write) button.
3
Place ND filter on the lens so
that the optimum image is
obtain.
4
6
01
29
Press PAUSE (Write) button.
(Note 3)
5
6
02
Check the data changes to
“01”.
6
6
0C
Check the data is “00”.
Note 3: The adjustment data will be automatically input to page:
F, address: 44 to 55.
Processing after completing adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
01
25
Press PAUSE (Write) button.
3
6
02
Check the data changes to
“01”.
4
6
01
00
Press PAUSE (Write) button.
5
0
01
00
6
Perform “Flange Back
Check”.
5.
Flange Back Check
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note 1: Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
Note 2: When the auto focus is ON, the lens can be checked if it
is focused or not by observing the data on the page: 1 of
the adjusting remote commander.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Checking method:
Order Page Address Data
Procedure
1
Place the Siemens star 2.0 m
from the front of the lens.
2
To  open the IRIS, decrease
the luminous intensity to the
Siemens star up to a point be-
fore noise appear on the image.
3
6
40
01
4
6
41
01
5
Shoot the Siemens star with
the zoom TELE end.
6
Turn on the auto focus.
7
0
03
0F
8
1
Check that the lens is
focused. (Note 2)
9
6
21
10
10
Shoot the Siemens star with
the zoom WIDE end.
11
Observe the TV monitor and
check that the lens is
focused.
Processing after completing adjustment:
Order Page Address Data
Procedure
1
6
21
00
2
6
40
00
3
6
41
00
4
0
03
00
6-24
DCR-HC36/HC36E_ADJ
How to release the picture frame setting:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
90
00
3
6
91
00
4
6
92
00
5
6
93
00
Check on the oscilloscope
1. Horizontal period
Fig. 6-1-11
2. Vertical period
Fig. 6-1-12
Check on the monitor TV (Underscanned mode)
Fig. 6-1-13
A=B
C=D
A
B
C
D
E=F
V
E
F
Color bar chart picture frame
Monitor TV picture frame
6.
Picture Frame Setting
(Color reproduction adjustment frame)
Subject
Color bar chart
(Color reproduction adjustment
frame)
(1 m (PTB-450) or 40 cm (PTB-
1450) from the front of lens)
Measurement Point
Video terminal of A/V OUT jack
(75 
Ω terminated)
Measuring Instrument
Oscilloscope and monitor TV
Specified Value
A=B, C=D, E=F
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Perform “Flange Back Adjustment” before this adjust-
ment.
Switch setting
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADY SHOT (Menu setting) ..................................... OFF
5) FOCUS (Menu Setting) ......................................... MANUAL
Setting method:
Order
Procedure
1
Adjust the zoom and the camera direction, and set
the specified position.
2
Mark the position of the picture frame on the monitor
TV, and adjust the picture frame to the this position
in following adjustment using “Color reproduction
adjustment frame”.
How to read the XH, XL, YH and YL data:
Order Page Address Data
Procedure
1
0
03
18
2
1
Read XH data and XL data.
(Note 3)
3
0
03
22
4
1
Read YH data and YL data.
(Note 3)
Note 3: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX : XX
XL or YL data
XH or YH data
How to reset the zoom and focus when they deviated:
If the zoom and focus deviated due to some reason, reset them in
the following method.
Order Page Address Data
Procedure
1
6
90
XL
2
6
91
XH
3
6
92
YL
4
6
93
YH
5
6
01
79
Press PAUSE (Write) button.
6-25
DCR-HC36/HC36E_ADJ
7.
Picture Frame Setting (Center frame)
Subject
Clear chart
(Center frame)
(1 m (PTB-450) or 40 cm (PTB-
1450) from the front of lens)
Measurement Point
Video terminal of A/V OUT jack (75
Ω terminated)
Measuring Instrument
Monitor TV
Specified Value
Whole of the screen is white
Note 1: Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) ZOOM .................................................................... WIDE end
4) DIGITAL ZOOM (Menu setting) .................................... OFF
5) STEADYSHOT (Menu setting) ...................................... OFF
Setting method:
1) Shoot a clear chart in the center of screen with the zoom at
WIDE end.
2) Check with the zoom at WIDE end that the clear chart is shot
larger than the size shown in the figure. (Fig.6-1-14)
3) In the following adjustment, if the “Center frame” is used, ad-
just the clear chart to this position.
Fig. 6-1-14
With the zoom at WIDE end, shoot the clear chart
larger than this size. 
A
A
A
B
B
B
8.
F No. Standard Data Input 
RadarW
RadarW
RadarW
Adjust the dispersion of the lens iris every F mumber, and com-
pensate the exposure.
Adjustment Page
F
Adjustment Address
1C to 23
Note 1: Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Input the following data to page: F, address: 1C to 23.
Note 2: Press the PAUSE (Write) button of the adjustment re-
mote commander each time to set data.
Address
Data
1C
0D
1D
0F
1E
0C
1F
03
20
FD
21
06
22
07
23
07
3) Select page: 0, address: 01, and set data: 00.
6-26
DCR-HC36/HC36E_ADJ
Processing after completing adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
6
9D
00
3
0
01
00
NTSC model
PAL model
Fig. 6-1-15
9.
Color Reproduction Adjustment
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Subject
Color bar chart
(Color reproduction adjustment
frame)
Measurement Point
Video terminal of A/V OUT jack (75
Ω terminated)
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
33, 35, 3A, 3B
Specified Value
All color luminance points should
settle within each color reproduction
frame.
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Perform “Flange Back Adjustment” and “F No. Standard
Data Input” before this adjustment.
Note 3: NTSC model: DCR-HC36
PAL model: DCR-HC36E
Switch setting:
1) POWER ............................................. CAMERA-TAPE mode
2) NIGHTSHOT PLUS ........................................................ OFF
3) DIGITAL ZOOM (Menu setting) .................................... OFF
4) STEADYSHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
Check that the picture frame
is “Color Reproduction
Adjustment Frame”. If not,
perform “6. Picture Frame
Setting (Color Reproduction
Adjustment Frame) ”
2
0
01
01
3
6
9D
83
4
6
01
3D
Press PAUSE (Write) button.
5
F
80
Set the following data, and
press PAUSE button.
77: NTSC model
F7: PAL model
6
Adjust the GAIN and PHASE
of the vectorscope, and set to
the burst luminance point to
the burst position of color re-
production frame.
7
F
33
Change the data and settle each
color luminance point in each
color reproduction frame.
(Note 4)
Note 4: Be sure to press the PAUSE (Write) button of the adjust-
ing remote commander before changing the addresses.
If not, the new data will not be written to the memory.
35
3A
3B
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Burst 
position
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Burst 
position