DOWNLOAD Sony DCR-HC28 (serv.man3) Service Manual ↓ Size: 555.42 KB | Pages: 59 in PDF or view online for FREE

Model
DCR-HC28 (serv.man3)
Pages
59
Size
555.42 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS BRAZIL
File
dcr-hc28-sm3.pdf
Date

Sony DCR-HC28 (serv.man3) Service Manual ▷ View online

6-11
DCR-HC28_ADJ
2.
Modification of 8, C, 1C Page Data
If the 8, C, 1C page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages 8, C, set data: 00 to page: 0,
address: 10, and then select pages 8, C.
3) If modification of data on pages 1C, set data: 01 to page: 0,
address: 10, and then select pages C. After the modification of
data finished, return the data on page: 0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after completing modification 8, C, 1C page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE (Write) button.
1-2-2.
Initialization of 8, C, 1C Page Data
Note:
If reading/writing data on pages 1C, set data: 01 to page: 0,
address: 10, and then select pages C. By this data setting,
the pages 1C can be selected.
After the data reading/writing finished, return the data on
page: 0, address: 10 to “00”.
1.
Initializing of 8, C, 1C Page Data
Note 1:
If “Initialization of Pages 8, C, 1C” is executed, all data
on pages 8, C, 1C are initialized. (Only an individual
page cannot be initialized)
Note 2:
If the 8, C, 1C page data has been initialized, the follow-
ing adjustments need to be performed again.
1) Modification of 8, C, 1C page data
2) Electronic viewfinder system adjustments
3) LCD system adjustments
4) Node unique ID No. input
5) Servo, RF system adjustments
6) Video system adjustments.
Adjustment Page
8
Adjustment Address
00 to FF
Adjustment Page
C
Adjustment Address
10 to FF
Adjustment Page
1C
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
3
81
Check that the data is “00”.
4
3
80
0C
Press PAUSE (Write) button.
5
3
80
Check the data changes to
“1C”.
6
Perform “Modification of 8,
C, 1C Page Data”
6-12
DCR-HC28_ADJ
3.
8 Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 91
Fixed data-1 (Initialized data)
92
Fixed data-2
93
Fixed data-1 (Initialized data)
94
Fixed data-2
95 to 99
Fixed data-1 (Initialized data)
9A
Fixed data-2
9B to FF
Fixed data-1 (Initialized data)
4.
C Page Table
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
10
EE
EE
Switching position adj.
11
00
00
12
00
00
13
00
00
14, 15
Fixed data-1 (Initialized data)
16
20
20
CAP FG duty adj.
17 to 24
Fixed data-1 (Initialized data)
25
8E
8C
S VIDEO OUT Y level adj.
26
AB
AD
S VIDEO OUT chroma level adj.
27
7A
7B
28 to 3B
Fixed data-1 (Initialized data)
3C
Fixed data-2
3D, 3E
Fixed data-1 (Initialized data)
3F
7F
88
EVF automatic adj. (VCO adj.)
40
89
7E
41 to 44
Fixed data-1 (Initialized data)
45
8B
8B
White balance adj. (EVF)
46
80
80
47
36
36
EVF automatic adj. (Contrast adj.)
48 to 4C
Fixed data-1 (Initialized data)
4D
Fixed data-2
4E, 4F
Fixed data-1 (Initialized data)
50
7F
88
LCD automatic adj. (VCO adj.)
51
89
7E
52
52
52
V-COM adj. (LCD)
53, 54
Fixed data-1 (Initialized data)
55
Fixed data-2
56
88
88
Transmissive mode white balance
57
7E
7E
adj. (LCD)
58
3C
3C
LCD automatic adj. (Contrast adj.)
59
Fixed data-2
5A to 65
Fixed data-1 (Initialized data)
66
67
Fixed data-2
68 to 7A
Fixed data-1 (Initialized data)
7B
7C
Fixed data-2
7D to A9
Fixed data-1 (Initialized data)
AA
Fixed data-2
AB
Fixed data-1 (Initialized data)
AC
Fixed data-2
6-13
DCR-HC28_ADJ
Address
Initial value
Remark
NTSC PAL
AD to B1
Fixed data-1 (Initialized data)
B2
B3
Fixed data-2
B4
Fixed data-1 (Initialized data)
B5
Fixed data-2
B6 to D1
Fixed data-1 (Initialized data)
D2
D3
Fixed data-2
D4
D5 to DD
Fixed data-1 (Initialized data)
DE
DF
Fixed data-2
E0
08
08
E1
00
00
E2
46
46
E3
01
01
E4
02
02
Node unique ID No. input
E5
00
00
E6
00
00
E7
00
00
E8 to F3
Fixed data-1 (Initialized data)
F4
00
00
F5
00
00
F6
00
00
F7
00
00
F8
00
00
Emergency memory address
F9
00
00
FA
00
00
(Mechanism section)
FB
00
00
FC
00
00
FD
00
00
FE
00
00
FF
00
00
5.
1C Page Table
Note 1:
If reading/writing data on pages 1C, set data: 01 to page:
0, address: 10, and then select pages C. By this data set-
ting, the pages 1C can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, C, 1C Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, C, 1C Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to B2
Fixed data-1 (Initialized data)
B3
00
00
SD error rate check (LP)
B4
00
00
B5
00
00
B6
00
00
B7
00
00
B8
80
80
B9
00
00
BA
00
00
BB
00
00
BC
00
00
BD
00
00
BE
00
00
BF
00
00
C0
00
00
C1
00
00
C2
00
00
C3
80
80
C4
00
00
C5
00
00
C6
00
00
C7
00
00
C8
00
00
C9 to D4
Fixed data-1 (Initialized data)
D5
Fixed data-2
D6 to F6
Fixed data-1 (Initialized data)
F7
Fixed data-2
F8 to FF
Fixed data-1 (Initialized data)
C Page Table
6-14
DCR-HC28_ADJ
1-2-3.
Initialization of E, F, 1F Page Data
Note:
Check that the data of page: 0, address: 10 is “00”.
1.
Initializing of E, F, 1F Page Data
Note 1:
If “Initialization of Pages E, F, 1F” is executed, all data
on pages E, F, 1F are initialized. (Only an individual page
cannot be initialized)
Note 2:
If the E, F, 1F page data has been initialized, the follow-
ing adjustments need to be performed again.
1) Modification of E, F, 1F page data
2) Camera system adjustments
Note 3:
NTSC model: DCR-HC28
PAL model: DCR-HC27E/HC28E
Adjustment Page
E
Adjustment Address
00 to FF
Adjustment Page
F
Adjustment Address
10 to FF
Adjustment Page
1F
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
6
01
Set the following data, and
press PAUSE button.
2D: NTSC model
2F: PAL model
4
6
03
FF
Press PAUSE (Write) button.
5
6
02
Check the data changes to
“01”.
6
6
01
00
Press PAUSE (Write) button.
7
Perform “Modification of E,
F, 1F Page Data”
2.
Modification of E, F, 1F Page Data
If the E, F, 1F page data has been initialized, change the data of
the “Fixed data-2” address shown in the following table by manual
input.
Modifying method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages E, F, set data: 00 to page: 0,
address: 10, and then select pages E, F.
3) If modification of data on pages 1F, set data: 01 to page: 0,
address: 10, and then select pages F. After the modification of
data finished, return the data on page: 0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after completing modification E, F, 1F page data:
Order Page Address Data
Procedure
1
0
10
00
2
2
00
29
3
2
01
29
Press PAUSE (Write) button.
4
Perform “36MHz Origin
Oscillation Adjustment” of
CAMERA SYSTEM
ADJUSTMENTS.
Page of 59
Display

Click on the first or last page to see other DCR-HC28 (serv.man3) service manuals if exist.