Movie / SECTION 6 ADJUSTMENTS
File
dcr-dvd403-dcr-dvd403e-dcr-dvd803-dcr-dvd803e-sm3.pdf
Date

Sony DCR-DVD403 / DCR-DVD403E / DCR-DVD803 / DCR-DVD803E (serv.man3) Service Manual ▷ View online

6-69
DCR-DVD403/DVD403E/DVD803/DVD803E
3-2.
APPLICATION FOR ADJUSTMENT
(SeusCam)
The adjustment software (SeusCam) can change operational coef-
ficients of signal processing, EVR data, etc. same as the adjust-
ment remote commander. The SeusCam performs two-way com-
munication between PC and camcoder using the USB terminal.
The two-way communication result data can be written in the non-
volatile memory.
Note 1:
The SeusCam is used exclusively for the camcoders
(DCR, DHR, CCD, etc.). It cannot be used for digital
cameras (DSC, MVC, etc.).
Note 2:
Before using the SeusCam, set the following data using
the adjustment remote commander.
1) Select page: 0, address: 01, and set data: 01.
2) Select page: A, address: 14, set data: 01, and press
the PAUSE button.
After use, release the set data.
1) Select page: 0, address: 01, and set data: 01.
2) Select page: A, address: 14, set data: 00, and press
the PAUSE button.
3) Select page: 0, address: 01, and set data: 00.
1.
Connection
1) Connect the HASP key to the USB terminal of the PC.
2) Connect the PC and camcoder with the USB cable.
3) Start the SeusCam on the PC.
4) Click 
[Connect]
 on the SeusCam screen. If the connection is
normal, the SeusCam screen will be as shown in Fig. 6-3-2,
indicating the
 
“connected”
 
state.
Note:
The SeusCam will go in
 
“disconnect” state, if the set is
turned off (for instance, by resetting the set). In such a
case, click 
[Connect]
  on the SeusCam screen to re-
store the
 
“connected”
 
state.
2.
Operation
• Page change
To change the page, click 
[Page]
 on the SeusCam screen and
enter the page to be changed. The page is displayed in hexa-
decimal notation.
• Address change
To change the address, click 
[Address]
 on the SeusCam screen
and enter the address to be changed. The address is displayed in
hexadecimal notation.
• Data change
To change the data, click 
[Set]
 on the SeusCam screen and en-
ter the data. The data is displayed in hexadecimal notation.
This operation does not write the data to the nonvolatile memory.
• Data writing
To write the data to the nonvolatile memory, click 
[Write]
 on
the SeusCam screen and enter the data to be written.
• Data reading
The data displayed on the SeusCam screen are the data values
at the time when the pages and addresses were set, and they are
not updated automatically. To check the data change, click
[Read]
 on the SeusCam screen and update the displayed data.
3.
Difference in Display Between SeusCam and
Adjustment Remote Commander
There is no difference in display of address and data between
SeusCam and adjustment remote commander. Though the page is
displayed in one digit on the adjustment remote commander, it is
displayed in two digits on the SeusCam.
The “page 1A” or “page 1F” is selected after setting data: 01 to
the page: 0, address: 10 on the adjustment remote commander,
while it can be selected by clicking the 
[Page]
 and entering “1A”
or “1F” on the SeusCam. For the “page A” or “page F”, enter “0A”
or “0F”.
4.
Precaution on Use of SeusCam
Wrong SeusCam operation could clear correct adjustment data.
To prevent the data clear by mistake, it is recommended to save all
adjustment data by clicking 
[Page Edit]
 on the SeusCam screen
before starting the adjustment.
Saving Method:
1)
Click 
[Page Edit]
 on the SeusCam screen to display the SeusCam
Page Edit screen.
2)
Click 
[Page]
, and enter the page number to be saved.
3)
Click 
[Read]
 to read the data to be saved from the camera.
4)
Click 
[File]
 and save the data to PC.
Loading Method:
1) Select page: 00, address: 01 and set data: 01.
2) Click 
[Page Edit]
 on the SeusCam screen to display the SeusCam
Page Edit screen.
3) Click 
[File]
 and load the data from PC.
4) Click 
[Write]
 on the SeusCam Page Edit screen.
Fig. 6-3-2
6-70
DCR-DVD403/DVD403E/DVD803/DVD803E
Hexadecimal-decimal Conversion Table
Lower digit of
hexadecimal 
Upper digit 
of hexadecimal
0
1
2
3
4
5
6
7
8
9
A
(
A
)
B
(
b
)
C
(
c
)
D
(
d
)
E
(
E
)
F
(
F
)
0
1
2
3
4
5
6
7
8
9
A (
A
)
B (
b
)
C (
c
)
D (
d
)
E (
E
)
F (
F
)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
77
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
174
159
175
160
161
162
163
164
165
166
167
168
169
170
171
172
173
177
176
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
0
1
Note:
The characters shown in the parenthesis (  ) shown the display on the adjustment remote commander.
(Example)
If the DDS display or the adjustment remote commander shows BD (
bd
);
Because the upper digit of the adjustment number is B (
b
), and the lower digit is D (
d
), the meeting point 
“189” of 1 and 2 in the above table is the corresponding decimal number.
0
2
3-3.
DATA PROCESS
The calculation of the DDS display and the adjustment remote
commander display data (hexadecimal notation) are required for
obtaining the adjustment data of some adjustment items. In this
case, after converting the hexadecimal notation to decimal nota-
tion, calculate and convert the result to hexadecimal notation, and
use it as the adjustment data. Indicates the hexadecimal-decimal
conversion table.
Table 6-3-1
6-71
DCR-DVD403/DVD403E/DVD803/DVD803E
2.
Emergence Memory Address
2-1. Emergency Memory Address (Camera section)
Page 19
Address 87 to 8A
Note:
If reading/writing data on pages 19, set data: 01 to page:
0, address: 10, and then select pages: 9. By this data set-
ting, the pages 19 can be selected.
After the data reading/writing finished, return the data on
page: 0, address: 10 to “00”.
Address
Contents
87
EMG code when first error occurs
88
EMG code when second error occurs
89
EMG code when third error occurs
8A
EMG code when last error occurs
When no error occurs in this unit, data “00” is written in the above
addresses (87 to 8A). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency ad-
dress (87). In the same way, when the second error occurs, the
data corresponding to the error is written in the second emergency
address (88).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (8A).
Note:
After completing adjustments, be sure to initialize the data
of addresses 87 to 8A to “00”.
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
6
01
FD
Press PAUSE button.
3
6
02
Check the data changes to
“01”.
4
6
01
00
Press PAUSE button.
5
0
01
00
2-2. EMG Code (Emergency Code)
Codes corresponding to the errors which occur are written in 19
page, addresses 87 to 8A. The type of error indicated by the code
are shown in the following table.
Code
Emergency Type
00
No error
3-4.
SERVICE MODE
Note:
Before performing the adjustment, check the data of page:
0, address: 10 is “00”. If not, select page: 0, address: 00,
and set data “00”.
1.
Setting the Test Mode
Page A
Address 10
Data
Function
00
Normal
01
Forced MOVIE mode
02
Forced PLAY/EDIT mode
05
Forced STILL mode
06
Forced LINE input mode)
• Before setting the data , select page: 0, address: 01, and set data:
01.
• For page A, the data set will be recorded in the non-volatile
memory by pressing the PAUSE button of the adjustment re-
mote commander. In this case, take note that the test mode will
not be exited even when the main power is turned off (8.4 Vdc).
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjust-
ment remote commander. And select page: 0, address: 01, and
set data: 00.
6-72
DCR-DVD403/DVD403E/DVD803/DVD803E
4.
Lens Barrier Check
Page 6
Address 62
Note:
Check that the data of page: 0, address: 10 is “00”.
Using method:
Order Page Address Data
Procedure
1
Set the unit to MOVIE mode
or STILL mode.
2
6
62
Check the data is “81”.
3
6
61
02
4
6
62
Check the data changes to
“42”.
5
Check that the lens barrier is
closed.
6
6
61
01
7
6
62
Check the data is “81”.
8
Check that the lens barrier is
opened.
9
6
61
00
3.
Bit Value Discrimination
Bit values must be discriminated using the display data of the ad-
justment remote commander for the following items.  Us the table
below to discriminate if the bit value is “1” or “0”.
(Example) If the remote commander display is “8E”, bit value from
bit 7 to bit 4 can be discriminated from the column 
A
,
and those from bit 3 to bit 0 from column 
B
.
Page
Address
bit3 to bit0 discrimination
bit7 to bit4 discrimination
Display on the adjustment remote commander
Display on the
adjustment
remote
commander
0
1
2
3
4
5
6
7
8
9
A (
A
)
B (
b
)
C (
C
)
D (
d
)
E (
E
)
F (
F
)
Bit values
bit3
or
bit7
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
bit2
or
bit6
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
bit1
or
bit5
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
bit0
or
bit4
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
A
B
Page of 82
Display

Click on the first or last page to see other DCR-DVD403 / DCR-DVD403E / DCR-DVD803 / DCR-DVD803E (serv.man3) service manuals if exist.