DOWNLOAD Sony DCR-DVD305 (serv.man3) Service Manual ↓ Size: 1.84 MB | Pages: 89 in PDF or view online for FREE

Model
DCR-DVD305 (serv.man3)
Pages
89
Size
1.84 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS BRAZIL`
File
dcr-dvd305-sm3.pdf
Date

Sony DCR-DVD305 (serv.man3) Service Manual ▷ View online

6-22
DCR-DVD305
Address
Initial value
Remark
NTSC PAL
7E
28
20
7F
00
00
80
62
60
81
7A
75
82
81
7B
83
7C
76
84
6A
63
85
1E
1E
Mechanical shutter adj.
86
80
80
87
80
80
88
80
80
89
80
80
8A
80
80
8B
80
80
8C to AB
Fixed data-1 (Initialized data)
AC
Fixed data-2
AD to B1
Fixed data-1 (Initialized data)
B2
Fixed data-2
B3 to CB
Fixed data-1 (Initialized data)
CC
CD
Fixed data-2
CE, CF
Fixed data-1 (Initialized data)
D0
Fixed data-2
D1, D2
Fixed data-1 (Initialized data)
D3
D4
Fixed data-2
D5 to F7
Fixed data-1 (Initialized data)
F8
F9
Fixed data-2
FA
FB to FF
Fixed data-1 (Initialized data)
F Page table
5.
14 Page table
Note 1:
If reading/writing data on pages 14, set data: 01 to page:
0, address: 10, and then select pages: 4. By this data set-
ting, the pages 14 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to“1. Initializing the
E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 3F
Fixed data-1 (Initialized data)
40
41
Fixed data-2
42
Fixed data-1 (Initialized data)
43
44
Fixed data-2
45
Fixed data-1 (Initialized data)
46
47
Fixed data-2
48 to E7
Fixed data-1 (Initialized data)
E8
25
25
E9
00
00
EA
07
07
EB
00
00
EC
25
25
ED
00
00
EE
07
07
AWB standard data input
EF
00
00
F0
25
25
F1
00
00
F2
07
07
F3
00
00
F4
15
15
F5
00
00
F6
0C
0C
F7
00
00
F8
15
15
F9
00
00
FA
0C
0C
AWB adj.
FB
00
00
FC
15
15
FD
00
00
FE
0C
0C
FF
00
00
6-23
DCR-DVD305
Address
Initial value
Remark
NTSC PAL
F4
Fixed data-2
F5 to FF
Fixed data-1 (Initialized data)
6.
19 Page table
Note 1:
If reading/writing data on pages 19, set data: 01 to page:
0, address: 10, and then select pages: 9. By this data set-
ting, the pages 19 can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to“1. Initializing the
E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 53
Fixed data-1 (Initialized data)
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
60
Fixed data-2
61
62
63
64
65
66
67
68
69
6A
6B
6C to 76
Fixed data-1 (Initialized data)
77
78
Fixed data-2
79 to 7D
Fixed data-1 (Initialized data)
7E
Fixed data-2
7F to 86
Fixed data-1 (Initialized data)
87
00
00
88
00
00
Emergency memory address
89
00
00
(Camera section)
8A
00
00
8B to E0
Fixed data-1 (Initialized data)
E1
Fixed data-2
E2 to F3
Fixed data-1 (Initialized data)
6-24
DCR-DVD305
7.
1E Page table
Note 1:
If reading/writing data on pages 1E, set data: 01 to page:
0, address: 10, and then select pages: E. By this data set-
ting, the pages 1E can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (Refer to“1. Initializing the
E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (Refer to“2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 17
Fixed data-1 (Initialized data)
18
19
1A
1B
1C
Fixed data-2
1D
1E
1F
20 to 9F
Fixed data-1 (Initialized data)
A0
Fixed data-2
A1 to D1
Fixed data-1 (Initialized data)
D2
Fixed data-2
D3
Fixed data-1 (Initialized data)
D4
D5
Fixed data-2
D6 to D8
Fixed data-1 (Initialized data)
D9
DA
DB
Fixed data-2
DC
DD to FF
Fixed data-1 (Initialized data)
8.
1F Page table
Note 1:
If reading/writing data on pages 1F, set data: 01 to page:
0, address: 10, and then select pages: F. By this data set-
ting, the pages 1F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Fixed data-1: Initialized data. (“Refer to 1. Initializing
the E, F, 14, 19, 1E, 1F Page Data”)
Fixed data-2: Modified data. (“Refer to 2. Modification
of E, F, 14, 19, 1E, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 04
Fixed data-1 (Initialized data)
05
Fixed data-2
06 to 0D
Fixed data-1 (Initialized data)
0E
Fixed data-2
0F to 48
Fixed data-1 (Initialized data)
49
4A
Fixed data-2
4B to AB
Fixed data-1 (Initialized data)
AC
Fixed data-2
AD to B0
Fixed data-1 (Initialized data)
B1
Fixed data-2
B2, B3
Fixed data-1 (Initialized data)
B4
Fixed data-2
B5 to BB
Fixed data-1 (Initialized data)
BC
Fixed data-2
BD to C9
Fixed data-1 (Initialized data)
CA
CB
Fixed data-2
CC to E6
Fixed data-1 (Initialized data)
E7
Fixed data-2
E8 to FF
Fixed data-1 (Initialized data)
6-25
DCR-DVD305
1-2-3.
Initialization of C, 1C Page Data
1.
Initializing of C, 1C Page Data
Note1:
If “Initialization of Pages C, 1C” is executed, all data on
pages C, 1C are initialized. (Only an individual page can-
not be initialized)
Note2 :
If the C, 1C page data has been initialized, the following
adjustments need to be performed again.
1) Modification of C, 1C page data
2) LCD system adjustments
3) EVF system adjustments
4) Video system adjustments
Adjustment Page
C
Adjustment Address
10 to FF
Adjustment Page
1C
Adjustment Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
3
80
0F
Press PAUSE button.
Check the data changes to
4
3
80
“1F”.
Perform “Modification of C,
5
1C Page Data”
Note 3:
If other than adjustment address was initialized, the ad-
justed data is not initialized.
2.
Modification of C, 1C Page Data
If the C, 1C page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) If modification of data on pages C, set data: 00 to page: 0,
address: 10, and then select pages C.
3) If modification of data on pages 1C, set data: 01 to page: 0,
address: 10, and then select pages C.
After the modification of data finished, return the data on page:
0, address: 10 to “00”.
4) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note 1:
If copy the data built in the different model, the
camcorder may not operate.
5) When changing the data, press the PAUSE (Write) button of
the adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
6) Check that the data at the addresses for adjustment are initial
values (adjustment initial values) listed in the table.
If different, change them to the adjustment initial values.
Processing after Completing Modification C, 1C page data:
Order Page Address Data
Procedure
1
0
10
00
2
7
01
FF
3
7
00
01
Press PAUSE (Write) button.
Page of 89
Display

Click on the first or last page to see other DCR-DVD305 (serv.man3) service manuals if exist.