DOWNLOAD Sony DCR-DVD305 (serv.man3) Service Manual ↓ Size: 1.84 MB | Pages: 89 in PDF or view online for FREE

Model
DCR-DVD305 (serv.man3)
Pages
89
Size
1.84 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS BRAZIL`
File
dcr-dvd305-sm3.pdf
Date

Sony DCR-DVD305 (serv.man3) Service Manual ▷ View online

6-38
DCR-DVD305
5.
CAMERA Adjustment 2
(Using the flange back adjustment chart and subject
more than 500 m away)
5-1. CAMERA Adjustment 2 (1)
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back (1) and Zoom Lever Center Adj.
3. Release of Data Setting during Camera Adj.
[Preparation]
1) Place the Flange back adjustment chart at 2 m position away
from the lens.
2) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
[Adjusting method]
1) Click the 
[Start  1 ]
 button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation”.
4) If the 
[OK]
 button is clicked, “2. Flange Back (1) and Zoom
Lever Center Adj.” and “3. Release of Data Setting during
Camera Adj.” will be executed.
5) Upon successful completion of all items of the CAMERA
Adjustment 2 (1), the following message is displayed. Click
the 
[OK]
 button.
6) Perform “CAMERA Adjustment 2 (2)”.
( )
5-2. CAMERA Adjustment 2 (2)
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back (2) Adj.
3. Release of Data Setting during Camera Adj.
[Preparation]
1) Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away.
(subjects with clear contrast such as building, etc.)
(Nearby subjects less than 500 m away should not be in the screen)
[Adjusting method]
1) Click the 
[Start  2 ]
 button of the CAMERA Adjustment 2.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject by referring to “Preparation”.
4) If the 
[OK]
 button is clicked, “2. Flange Back (2) Adj.” will be
executed.
The following message is displayed during the execution of
adjustment, and then place the ND filter on the lens so as to
obtain the optimum image.
5) If “2. Flange Back Adj.” completed successfully, “3. Release
of Data Setting during Camera Adj.” will be executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 2 (2), the following message is displayed. Click
the 
[OK]
 button.
(
)
6-39
DCR-DVD305
6.
CAMERA Adjustment 3
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Flange Back Check
3. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Click the [Start] button of the CAMERA Adjustment 3.
2) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
3) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed. Set the sub-
ject in accordance with the message.
4) If the 
[OK]
 button is clicked, “2. Flange Back Check” is ex-
ecuted. The following messages are displayed, and then oper-
ate the camera to make a check in accordance with the mes-
sages.
5) Upon completion of “2. Flange Back Check”, “3. Release of
Data Setting during Camera Adj.” is executed.
6) Upon successful completion of all items of the CAMERA
Adjustment 3, the following message is displayed. Click the
[OK]
 button.
6-40
DCR-DVD305
7.
CAMERA Adjustment 4
[Automatic Adjustment Program execution items and
sequence]
1. Data Setting during Camera Adj.
2. Picture Frame Setting (Center Frame)
3. F No. & ND light quality Standard Data Input
4. MAX GAIN Adj.
5. Mechanical Shutter Adj.
6. Picture Frame Setting (Color Reproduction  Adjustment Frame)
7. Color Reproduction Adj.
8. Color Reproduction Check
9. Picture Frame Setting (AWB Adjustment Frame)
10. AWB Standard Data Input
11. LV Standard Data Input
12. AWB Adj.
13. AWB Check
14. Release of Data Setting during Camera Adj.
[Adjusting method]
1) Select the model (NTSC Model or PAL Model) with the Model
Select radio button.
Note:
NTSC model: DCR- DVD205/DVD305/DVD705/
DVD755
PAL model: DCR-DVD205E/DVD304E/DVD305E/
DVD705E/DVD755E
2) Click the 
[Start]
 button of the CAMERA Adjustment 4.
3) The Automatic Adjustment Program executes “1. Data Setting
during Camera Adj.”.
4) Upon successful completion of the “1. Data Setting during
Camera Adj.”, the following message is displayed during the
execution of “2. Picture Frame Setting (Center Frame)”. Set
the subject in accordance with the message.
 5) If  the 
[OK]
  button is clicked, the following message is dis-
played, and then check the size of clear chart shot on the moni-
tor screen.
6) After the checking, if the 
[OK]
 button in the message window
is clicked, the adjustment items from “3. F No. & ND light
quality Standard Data Input” to “5. Mechanical Shutter Adj.”
are executed.
7) Upon successful completion of the “5. Mechanical Shutter
Adj.”, the following message is displayed. Then, change the
chart in accordance with the message.
 8) If the 
[OK]
 button is clicked, “6. Picture Frame Setting (Color
Reproduction Adjustment Frame)” is executed.
The following screen will appear, and then adjust the zoom
and the camera direction to set the picture frame. After the
setting finished, click the 
[End]
 button.
The buttons on this screen provide the following functions:
[Save the position]
 button
Saves the camera zoom and focus position data.
[Load the position]
 button
Reads the camera zoom and focus position data saved last and
moves the camera zoom and focus to that position.
Note 1:
The zoom and focus position data are saved with
“DCR_DVD205_ZoomFocusData.txt” file name in the
same holder as the Automatic Adjustment Program.
No position data can be read if this file is moved or de-
leted.
Note 2:
Only the latest position data can be saved. If the 
[Save
the position]
 button is clicked, the latest data are saved
overwriting the previous data.
6-41
DCR-DVD305
 9) After setting the picture frame, if the 
[End]
 button is clicked,
“7. Color Reproduction Adj.” is executed. The following mes-
sage is displayed, and then adjust the burst position of the
vectorscope.
10) If the 
[OK]
  button is clicked, the following message is dis-
played, and then adjust the luminance point of each color us-
ing the 
[Up]
/
[Down]
  button on the screen. After the adjust-
ment finished, click the 
[End]
 button.
11) After the adjustment, if the 
[End]
 button is clicked, “8. Color
Reproduction Check” is executed.
12) Upon successful completion of the “8. Color Reproduction
Check”, the following message is displayed. Then, set the pic-
ture frame in accordance with the message.
13) If the 
[OK]
 button is clicked, “9. Picture Frame Setting (AWB
Adjustment Frame)” is executed. The following messages are
displayed in the order given below during the execution. Then,
change the chart in accordance with the messages.
Fig. 6-1-13
NTSC model
PAL model
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Burst position
Burst position
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Page of 89
Display

Click on the first or last page to see other DCR-DVD305 (serv.man3) service manuals if exist.