DOWNLOAD Sony DCR-DVD105 / DCR-DVD105E / DCR-DVD605 / DCR-DVD605E (serv.man4) Service Manual ↓ Size: 1.42 MB | Pages: 82 in PDF or view online for FREE

Model
DCR-DVD105 DCR-DVD105E DCR-DVD605 DCR-DVD605E (serv.man4)
Pages
82
Size
1.42 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
dcr-dvd105-dcr-dvd105e-dcr-dvd605-dcr-dvd605e-sm4.pdf
Date

Sony DCR-DVD105 / DCR-DVD105E / DCR-DVD605 / DCR-DVD605E (serv.man4) Service Manual ▷ View online

6-42
DCR-DVD105/DVD105E/DVD605/DVD605E_ADJ
1-7.
AUDIO  SYSTEM  ADJUSTMENTS
Switch setting
REC MODE (Menu setting) ............................................... LP
Type of disc to use
DVD-RW (VF format)
[Connecting the measuring instruments for the audio]
Connect the audio system measuring instruments in addition to
the video system measuring instruments as shown in Fig. 6-1-15.
Fig. 6-1-15
Audio
oscillator
Attenuator
600 
600 
 (270 
 (1-249-410-11) +330 
 (1-249-411-11))
Main unit
Main unit
47 k 
47 k 
: 1-249-437-11
Audio level meter or
distortion meter
TV monitor
A/V OUT
 jack
A/V OUT
jack
L
R
Video
Audio (L)
Audio (R)
In Recording (MOVIE mode)
In Playback (PLAY/EDIT mode)
1. Overall Level Characteristics Check
Mode
Recording (MOVIE mode) and
playback (PLAY/EDIT mode)
Signal
400 Hz, 
−7.5 dBs signal:
Audio left and right terminal of A/V
OUT jack
Measurement Point
Audio left or right terminal of A/V
OUT jack
Measuring Instrument
Audio level meter
Specified Value
–7.5 
± 1.0 dBs
Checking Method:
1) Select page: 3, address: E2, set data: 08, and press the PAUSE
button.
2) Input the 400 Hz, –7.5 dBs signal in the audio left and right
terminal of A/V OUT jack.
3) Record the signal.
4) Remove the input signal.
5) Playback the recorded section.
6) Check that the 400 Hz signal level is the specified value.
7) Select page: 3, address: E2, set data: 00, and press the PAUSE
button.
2. Overall Distortion Check
Mode
Recording (MOVIE mode) and
playback (PLAY/EDIT mode)
Signal
400 Hz, –7.5 dBs signal:
Audio left and right terminal of A/V
OUT jack
Measurement Point
Audio left or right terminal of A/V
OUT jack
Measuring Instrument
Audio distortion meter
Specified Value
Below 0.4%
(200 Hz to 6 kHz BPF ON)
Checking Method:
1) Select page: 3, address: E2, set data: 08, and press the PAUSE
button.
2) Input the 400 Hz, –7.5 dBs signal in the audio left and right
terminal of A/V OUT jack.
3) Record the signal.
4) Remove the input signal.
5) Playback the recorded section.
6) Check that the distortion is the specified value.
7) Select page: 3, address: E2, set data: 00, and press the PAUSE
button.
6-43
DCR-DVD105/DVD105E/DVD605/DVD605E_ADJ
3.
Overall Noise Level Check
Mode
Recording (MOVIE mode) and
playback (PLAY/EDIT mode)
Signal
No signal:
Audio left and right teminal of A/V
OUT jack
Measurement Point
Audio left or right terminal of A/V
OUT jack
Measuring Instrument
Audio level meter
Specified Value
Below 
−45 dBs
(IHF-A filter ON, 20 kHz LPF ON)
Checking Method:
1) Select page: 3, address: E2, set data: 08, and press the PAUSE
button.
2) Connect the audio left terminal of A/V OUT jack to GND us-
ing a jumper wire.
Connect the audio right teminal of A/V OUT jack to GND
using a jumper wire.
3) Record the signal.
4) Playback the recorded section.
5) Remove the jumper wires.
6) Check that the noise level is the specified value.
7) Select page: 3, address: E2, set data: 00, and press the PAUSE
button.
6-44
DCR-DVD105/DVD105E/DVD605/DVD605E_ADJ
1-8.
ERROR
In case of an error during the execution of adjustment, the Auto-
matic Adjustment Program interrupts the processing at that point,
and displays an error message, and then terminates the program
execution there.
1-8-1.
Error Message
When an error message is displayed, perform the remedy given
below, and then retry adjustment. If the error message is displayed
though the remedy was performed, the circuits will be faulty.
1.
Connect Error
Fig. 6-1-16
Symptom
USB communication with the set is abnormal.
Cause
• USB cable is not inserted tightly.
• Power supply is not installed correctly.
• Communication with SeusCam is abnormal.
Remedy
• Disconnect the USB cable once, and then re-
connect it tightly and check that the set is in
“USB Mode”.
• Install the power supply correctly.
• Start the SeusCam and click the [Connect] to
check that the connection state is established.
2.
RESET the CAMERA and Try Again
Fig. 6-1-17
Symptom
The camera is not ready for adjustment.
Cause
• Data error exists in the camera.
Remedy
• Reset the camera.
3.
Adjustment Time  Out
Fig. 6-1-18
Symptom
Adjustment does not finish within the specified
time.
Cause
• Adjustment conditions are wrong.
• Data error exists in the camera.
Remedy
• Check that the conditions such as a subject
are correct.
• Reset the camera.
4.
Adjustment NG
Fig. 6-1-19
Symptom
The adjusted data does not become the speci-
fied value.
Cause
• Adjustment conditions are wrong.
• Data error exists in the camera.
Remedy
• Check that the conditions such as a subject
are correct.
• Reset the camera.
This part indicates 
the adjustment 
item in which 
an error occurred.
This part indicates 
the adjustment 
item in which 
an error occurred.
6-45
DCR-DVD105/DVD105E/DVD605/DVD605E_ADJ
1-8-2.
Precautions When an Error Occurred
The Automatic Adjustment Program sets the data for adjustment
before the adjustment starts. Accordingly, if the adjustment termi-
nates by an error, the data during the adjustment may be left in the
camera.
Note:
With this data left in the camera, the camera will not oper-
ate normally.
In this case, the [Release Data Setting] button is displayed in “red”
on the screen as shown in Fig. 6-1-20, 21 and 22. Click the
[Release Data Setting] button to cancel the data setting. When the
data setting is cancelled, the button color becomes “white”.
Video System Adjustment screen
Fig. 6-1-20
Camera System Adjustment screen
Fig. 6-1-21
LCD/EVF System Adjustment screen
Fig. 6-1-22
Page of 82
Display

Click on the first or last page to see other DCR-DVD105 / DCR-DVD105E / DCR-DVD605 / DCR-DVD605E (serv.man4) service manuals if exist.