DOWNLOAD Sony CCD-TRV66E / CCD-TRV77E Service Manual ↓ Size: 36.34 MB | Pages: 127 in PDF or view online for FREE

Model
CCD-TRV66E CCD-TRV77E
Pages
127
Size
36.34 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie
File
ccd-trv66e-ccd-trv77e.pdf
Date

Sony CCD-TRV66E / CCD-TRV77E Service Manual ▷ View online

5-31
3-1-2. Precautions on Adjusting
1)
The adjustments of this unit are performed in the VTR mode
or camera mode.
To set to the VTR mode, set the power switch to “VTR or
PLAYER” or set the “Forced VTR Power ON mode” using the
adjustment remote commander (Note 1).
To set to the Camera mode, set the power switch to “CAMERA”
or set the “Forced Camera Power ON mode” using the
adjustment remote commander (Note 2).
After completing adjustments, be sure to exit the “Forced VTR
Power ON Mode” or “Forced Camera Power ON Mode”. (Note 3)
2)
By setting the “Forced VTR Power ON mode” or “Forced
Camera Power ON mode”, the video section can be operate
even if even if the front panel block (MA-351 board, power
switch, microphone unit) has been removed. When removing
the front panel block disconnect the following connector.
1. VC-214 board CN903 (20P 0.5mm)
3)
The lens block (CD-209 board) and VL-23 board (CCD-
TRV66E) or the intelligent accessory shoe (CCD-TRV77E)
need not be connected except during battery end adjustment.
To remove, disconnect the following connectors.
1. VC-214 board CN501 (16P, 0.5mm)
2. VC-214 board CN551 (24P, 0.5mm)
3. VL-23 board CN151 (8P, 0.5mm) (CCD-TRV66E)
4. Intelligent accessory shoe (8P, 0.8mm) (CCD-TRV77E)
4)
Cabinet (R) (Camera function switch (CF-56 board), LCD
block, viewfinder) need not be connected. But removing the
cabinet (R) (removing the VC-214 board CN911) means
removing the lithium 3V power supply (CF-56 board) , data
such as date, time, user-set menus will be lost. After completing
adjustments, reset these data. If the cabinet (R) has been
removed, the self-diagnosis data, data on history of use (total
drum rotation time etc. ) will be lost. Before removing, note
down the self-diagnosis data and data on history use (data of
page: 2, address: A2 to AA). (Refer to the “Service Mode” for
the data on the history use.) To remove the cabinet (R),
disconnect the following connectors.
1. VC-214 board CN911 (50P, 0.5mm)
2. DD-117 board CN933 (10P, 1.0mm)
Note 1:
Setting the “Forced VTR Power ON” mode (VTR mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 02, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the VTR power to be turned
on with the front panel block removed.
After completing adjustments, be sure to exit the “Forced VTR
Power ON mode”.
Note 2:
Setting the “Forced Camera Power ON” mode (Camera mode)
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the front panel block removed.
After completing adjustments, be sure to exit the “Forced
Camera Power ON mode”.
Note 3:
Exiting the “Forced Power ON” mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
3-1-3. Adjusting Connectors
Some of the adjusting points of the video section are concentrated
at VC-214 board CN910. Connect the measuring instruments via
the CPC-7 jig (J-6082-382-A). The following table lists the pin
numbers and signal names of CN910.
Table 5-3-1.
Pin No.
1
2
3
4
5
6
7
8
Signal Name
LANC SIG
XCPC IN
IR VIDEO
AFC F0
BPF MONI
PB RF
RF AGC IN
REG GND
Pin No.
9
10
11
12
13
14
15
16
Signal Name
RF AGC OUT
REC RF
RF SWP
CAP FG
EVF BL
EVF BL 4.75V
VCO
EVF VG
Fig. 5-3-1.
CN910
1
16
Screw driver (–)
Cover
5-32
Connecting the TV Monitor and Regulated Power Supply
Battery terminal
Regulated power supply
8.4  0.1Vdc
+
_
Main Unit
VIDEO terminal
VIDEO
Connect when using the camera
mode or playing back.
TV monitor
3-1-4. Connecting the Equipments
Connecting the measuring instruments as shown in Fig. 5-3-2 and
perform the adjustments.
Fig. 5-3-2.
5-33
3-1-6. Input/Output Level and Impedance
Video input/output
Phono jack, 1 Vp-p, 75
,
unbalanced, sync negative
S video input/output
4-pin mini DIN
Luminance signal:
1Vp-p, 75
, unbalanced, sync negative
Chrominance signal:
0.286Vp-p 75
, unbalanced
Audio input/output
Phono jack,
Input:
–7.5 dBs, input impedance more
than 47 k
Output: –7.5 dBs, (at load impedance 47 k
), impedance
less than 2.2 k
3-1-7. Recording Mode (Standard 8/Hi8) switching
The record mode (Standard 8/Hi8) of this unit switches as shown in
the following table. The playback mode (Standard 8/Hi8) switches
automatically according to the recording mode of the tape played
back.
Fig. 5-3-3. Shows the color bar signals recorded on the alignment
tape.
Note :
Measure using the VIDEO terminal (Terminated at 75 
).
Fig. 5-3-3. Color Bar Signals of the Alignment Tape
1V
0.7V
0.3V
White (100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
Burst signal
Horizontal sync signal
0.3V
(100%)
Y
ello
w
Cy
an
Green
Magenta
Red
Blue
White
Blac
k
Color bar Pattern
Color bar signal waveform
3-1-5. Alignment Tape
The following table lists alignment tapes which are available.
Use the tape specified in the signal column for each adjustment.
If the type of tape to be used for checking operations is not specified,
use whichever type.
Name
Tracking
WR5-1CP
Video frequency
characteristics
WR5-7CE
Operation check
(SP mode)
WR5-5CSP
Operation check
(SP mode)
WR5-8CSE
Operation check
(LP mode)
WR5-4CL
Operation check
(LP mode)
WR5-8CLE
AFM stereo
Operation check
WR5-9CS
BPF adjustment
WR5-11CS
Record
-ing
mode
Standard
8 mm
Hi8
Standard
8 mm
Hi8
Standard
8 mm
Hi8
Standard
8 mm
Hi8
Tape
type
MP
ME
MP
ME
MP
ME
MP
MP
Tape
speed
SP
LP
SP
SP
LP
LP
SP
SP
Usage
Tape path
adjustment
Switching
position
adjustment
Frequency
characteristics
adjustment
Checking
operations
AFM stereo
Checking
operations
BPF
adjustment
Tape Used
ME
Hi8 MP
MP
Recording Mode
Hi8
Standard 8
5-34
3-2. SYSTEM CONTROL SYSTEM ADJUSTMENT
1. Initialization of D, E, F Page Data
If the D, E, F page data is erased due to some reason, perform “1-2.
INITIALIZATION OF D, E, F PAGE DATA”, of “5-1. CAMERA
SECTION ADJUSTMENT”
2. Battery End Adjustment (VC-214 board)
Set the battery end voltage.
If the voltage is incorrect, the life of the battery will shorten.
The image at the battery end will also be rough.
Mode
Camera recording
Subject
Arbitrary
Measurement Point
LCD display of the adjustment remote
commander
Measuring Instrument
Adjustment Page
D
Adjustment Address
30 to 34
Note 1:
The lens block and cabinet (R) must be connected.
Switch setting
1)
AUTO FOCUS ................................................................. OFF
2)
LCD screen .................................................................. Closed
3)
NIGHT SHOT .................................................................. OFF
4)
VIDEO LIGHT (CCD-TRV66E) ..................................... OFF
Connection:
1)
Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 5-3-4.
Adjusting method:
1)
Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 6.1 ± 0.1Vdc.
2)
Turn off the power supply.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Turn on the power supply.
5)
Load a cassette, and set to the camera recording mode.
6)
Select page: 0, address: 01, and set data: 01.
7)
Decrease the output voltage of the regulated power supply so
that the digital voltmeter display is 5.30 ± 0.01Vdc.
8)
Select page: 2, address: 5D, read the data, and this data is named
Dref.
9)
Select page: D, address: 30, set data: Dref, and press the PAUSE
button of the adjustment remote commander.
10) Convert Dref to decimal notation, and obtain Dref’. (Refer to
Table 5-4-1. “Hexadecimal-decimal conversion table” of “5-4.
Service Mode”.)
11) Calculate D
31
', D
32
', D
33
' and D
34
' using following equations
(decimal calculation), convert it to a hexadecimal number, and
input each adjustment address.
Address: 31
D
31
' = Dref’ + 5
Address: 32
D
32
' = Dref’ + 32
Address: 33
D
33
' = Dref’ + 53
Address: 34
D
34
' = Dref’ + 64
Note 2:
 After setting each data, be sure to press the PAUSE button.
12) Select page: 0, address: 01, and set data: 00.
+
+
+
Regulated power supply
Digital voltmeter
5.3 
±
 0.01 Vdc
Fig. 5-3-4.
Page of 127