Sony CCD-TRV66E / CCD-TRV77E Service Manual ▷ View online

5-27
6. V-COM Level Adjustment (PD-105 board)
Set the common electrode drive signal level of LCD to the specified
value.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 4 of CN5501 (PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
E
Adjustment Address
D7
Specified Value
A = 4.60 ± 0.05V
Note :
Perform “Bright Adjustment” and “Contrast Adjustment” before this
adjustment.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 55, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 7D, and set data: 00.
4)
Select page: E, address: D7, change the data and set the PANEL
COM signal level (A) to the specified value.
5)
Press the PAUSE button.
6)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button.
7)
Select page: 0, address: 01, and set data: 00.
7. Color Adjustment (PD-105 board)
Set the color saturation to the standard value. If deviated, the color
will be to dark or light.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 3 of CN5501 (VG)
   External trigger : Pin 4 of CN5501
   (PANEL COM)
Measuring Instrument
Oscilloscope
Adjustment Page
E
Adjustment Address
D2, DB
Specified Value
A = +0.03 ± 0.05V
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 57, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 7D, and set data: 20.
4)
Select page: E, address: D2, change the data and set the green
level (A) to the specified value in respect to white.
5)
Add 9 to the data of page: E, address: D2, and press the PAUSE
button.
6)
Select page: E, address: DB, set the same data as page: E,
address: D2, and press the PAUSE button.
7)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button.
8)
Select page: 6, address: 7D, and set data: 00.
9)
Select page: 0, address: 01, and set data: 00.
A
2H
Fig. 5-1-21.
Fig. 5-1-22.
A
2H
Green 
White (Reference level)
5-28
8. V-COM Adjustment (PD-105 board)
Set the DC bias of the common electrode drive signal of LCD to the
specified value.
If deviated, the LCD display will move, producing flicker and
conspicuous vertical lines.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
E
Adjustment Address
D9
Specified Value
The brightness difference between the
section A and section B is minimum.
Note :
Perform “Bright Adjustment” and “Contrast Adjustment” before this
adjustment.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 51, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 7D, and set data: 87.
4)
Select page: E, address: D9, change the data so that the
brightness of the section A and that of the section B is equal.
5)
Press the PAUSE button.
6)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: 6, address: 7D, and set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
9. White Balance Adjustment (PD-105 board)
Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
Mode
VTR stop
Signal
No signal
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
E
Adjustment Address
D3, D4
Specified Value
The LCD screen should not be colored.
Note 1:
Check the white balance only when replacing the following parts.
If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC5502
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 51, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 6, address: 7D, and set data: 02.
4)
Select page: E, address: D3 and D4, and set the data to the
initial value.
Note 2:
To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
5)
Check that the LCD screen is not colored. If colored, change
the data of page: E, address: D3 and D4 so that the LCD screen
is not colored.
Note 2:
To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
6)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button.
7)
Select page: 6, address: 7D, and set data: 00.
8)
Select page: 0, address: 01, and set data: 00.
Address
D3
D4
Data
98
7B
A
A
A
A
B
B
B
B
Fig. 5-1-23.
5-29
5-2. MECHANISM SECTION
ADJUSTMENT
Mechanism Section adjustments, checks, and replacement of
mechanism parts, refer to the separate volume “8mm Video
Mechanism Adjustment Manual 
   B Mechanism  ”.
2-1. OPERATING WITHOUT CASSETTE
1)
Refer to “Section 2. DISASSEMBLY” and supply the power
with the cabinet assembly removed. (So that the mechanical
deck can be operated.)
2)
Connect the adjustment remote commander to the LANC jack.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Close the cassette compartment without loading a cassette and
complete loading.
5)
Select page: 0, address: 01, and set data: 01.
6)
Select page: F, address: 2C, set data: 01, and press the PAUSE
button of the adjustment remote commander.
7)
Select page: D, address: 10, set data: 10, and press the PAUSE
button of the adjustment remote commander.
8)
Disconnect the power supply of the unit.
By carrying out the above procedure, the unit can be operated
without loading a cassette.
Be sure to carry out “Processing after Operations” after
checking the operations.
Set the data of page: D, address: 10 to the following if the
sensor ineffective mode, forced VTR power supply On mode
or forced camera power supply ON mode are to be used
together.
Forced VTR power ON mode ........................................ 12
Forced camera power ON mode .................................... 11
[Procedure after checking operations]
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 2C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
5)
Disconnect the power supply of the unit.
2-2. TAPE PATH ADJUSTMENT
1. Preparations for Adjustment
1)
Clean the tape path face (tape guide, capstan shaft, pinch roller).
2)
Connect the adjustment remote commander to the LANC jack.
3)
Turn on the HOLD switch of the adjustment remote
commander.
4)
Select page: 0, address: 01, and set data: 01.
5)
Select page: F, address: 2C, set data: 04, and press the PAUSE
button of the adjustment remote commander.
(Be sure to perform “Processing after operation” after
completing adjustments.)
6)
Connect the oscilloscope to VC-214 board CN910 via CPC-7
jig (J-6082-382-A).
Channel 1: VC-214 board, CN910 Pin 6
External trigger: VC-214 board, CN910 Pin !¡
7)
Playback an alignment tape for tracking. (WR5-1CP)
8)
Check that the oscilloscope RF waveform is flat at the entrance
and exit.
If not flat, adjust according to the separate volume “8mm Video
Mechanical Adjustment Manual 
   B Mechanism  ”.
9)
Perform “Processing after operations”, after completing
adjustment.
CN910 of VC-214 board
Table 5-2-1.
[Procedure after operations]
1)
Connect the adjustment remote commander, and turn on the
HOLD switch.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: F, address: 2C, set data: 00, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 0, address: 01, and set data: 00.
5)
Remove the power supply from the unit.
Fig. 5-2-1.
Pin No.
1
2
3
4
5
6
7
8
Signal Name
LANC SIG
XCPC IN
IR VIDEO
AFC F0
BPF MONI
PB RF
RF AGC IN
REG GND
Pin No.
9
10
11
12
13
14
15
16
Signal Name
RF AGC OUT
REC RF
RF SWP
CAP FG
EVF BL
EVF BL 4.75V
VCO
EVF VG
Must be flat 
5-30
5-3. VIDEO SECTION ADJUSTMENTS
3-1. PREPARATIONS BEFORE ADJUSTMENTS
Use the following measuring instruments for video section
adjustments.
3-1-1. Equipment to Required
1)
TV monitor
2)
Oscilloscope (dual-phenomenon, band width above 30 MHz
with delay mode) (Unless specified otherwise, use a 10 : 1
probe.)
3)
Frequency counter
4)
Pattern generator with video output terminal
5)
Digital voltmeter
6)
Audio generator
7)
Audio level meter
8)
Audio distortion meter
9)
Audio attenuator
10) Regulated power supply
11) Alignment tapes
• For tracking adjustment (WR5-1CP)
Parts code : 8-967-995-07
• For video frequency characteristics adjustment (WR5-7CE)
Parts code : 8-967-995-18
• For checking Standard 8 mode operations
• For LP (WR5-4CL)
Parts code : 8-967-995-56
• For SP (WR5-5CSP)
Parts code : 8-967-995-47
Note:
The following alignment tapes can also be used.
1) WR5-3CL (8-967-995-36)
2) WR5-4CSP (8-967-995-46)
• For checking Hi8 mode operations
• For LP (WR5-8CLE)
Parts code : 8-967-995-57
• For SP (WR5-8CSE)
Parts code : 8-967-995-48
• For Checking AFM stereo operations (WR5-9CS)
Parts code : 8-967-995-28
• For BPF adjustment (WR5-11CS)
Parts code : 8-967-995-76
12) Adjustment remote commander (J-6082-053-B)
13) CPC-7 jig (J-6082-382-A)
14) Power code (J-6082-223-A)
Note:
Connect the adjustment remote commander to the LANC jack,
and set the HOLD switch to the “ADJ” side.
15) AFM DEV jig (J-6082-312-A)
16) IR receiver jig (J-6082-383-A)
17) Extension cable (70P, 0.5mm)
For extension between the DD-117 board (CN931) and the VC-
214 board (CN914) (J-6082-439-A)