5-19
R-Y
2mm
B-Y
2mm
R-Y
B-Y
1.0mm
1.0mm
3mm
3mm
R-Y
B-Y
3mm
3mm
2.0mm
1.0mm
Fig. 5-1-10. (A)
Fig. 5-1-10. (B)
Fig. 5-1-10. (C)
11. White Balance Check
Subject
Clear chart
(Color reproduction adjustment frame)
Filter
Filter C14 for color temperature
correction
ND filter 1.0 and 0.3
Measurement Point
Video output terminal
Measuring Instrument
Vectorscope
Specified Value
Fig. 5-1-10. A to C
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
4)
VIDEO LIGHT (CCD-TRV66E) ..................................... OFF
Checking method:
1)
Check that the lens is not covered with either filter.
2)
Select page: 6, address: 01, set data: 0F, and press the PAUSE
button of the adjustment remote commander.
3)
Check that the center of the white luminance point is within
the circle shown Fig. 5-1-10. (A).
4)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
5)
Select page: 6, address: 01, set data: 23, and press the PAUSE
button.
6)
Place the C14 filter on the lens.
7)
Check that the center of the white luminance point settles in
the circle shown Fig. 5-1-10. (B).
8)
Remove the C14 filter, and place the ND filter 1.3 (1.0 +0.3)
on the lens.
9)
Check that the white luminance point stopped moving, and then
remove the ND filter 1.3.
10) Check that the center of the white luminance point settles within
the circle shown Fig. 5-1-10. (C).
Processing after Completing Adjustments
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjustment remote commander.
5-20
12. Angular Velocity Sensor Sensitivity Preset and
Steady Shot Check
Check the output of the angular velocity sensor.
Precautions on the Parts Replacement
There are two types of repair parts.
Type A
ENC03JA
Type B
ENC03JB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing, re-
adjust according to the adjusting method after replacement.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note)
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
5F, 60
Specified Value
PITCH data : 3000 to 4600
YAW data  : 3000 to 4600
Note:
Displayed data of page 1 of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
ZOOM .......................................................................... Center
2)
STEADY SHOT (Menu display) ...................................... ON
Checking method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: F, address: 5F, set data: 76, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: F, address: 60, set data: 63, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 0, address: 03, and set data: 11.
5)
Select page: 1, and check that the PITCH data satisfies the
specified value.
6)
Select page: 0, address: 03, and set data: 12.
7)
Select page: 1, and check that the YAW data satisfies the
specified value.
Processing after Completing Adjustments
1)
Select page: 0, address: 01, and set data: 00.
2)
Select page: 0, address: 03, and set data: 00.
3)
Check that the steady shot operations have been performed
normally.
5-21
1-4. MONOCHROME ELECTRONIC VIEWFINEDER
SYSTEM ADJUSTMENT
1-4-1. Horizontal Slant Check
Mode
Playback
Signal
Alignment tape :
For checking operation
(WR5-5CSP)
Monoscope section
Specified Value
± 1.5
°
Adjusting method:
1)
Adjust RV904 (BRIGHT) (VF-129 board) so that the CRT can
be seen easily and clearly.
2)
Check that the difference between the horizontal line and the
tilt of black mask satisfies the specified value.
1-4-2. Centering Adjustment
Mode
Playback
Signal
Alignment tape :
For checking operation
 (WR5-5CSP)
Monoscope section
Specified Value
± 4%
Adjusting method:
1)
Use the centering adjustment ring and adjust so that the left,
light, top, and bottom sides of the display are uniform. (Refer
to Fig. 5-1-12.)
Note:
As the centering position changes due to earth magnetism, rotate
it 360
°
 in the horizontal direction, and adjust with the center
section of the modifying position.
1-4-3. Focus Adjustment
Mode
Playback
Signal
Alignment tape :
For checking operation
(WR5-5CSP)
Monoscope section
Adjusting method:
1)
 Adjust the focus ring to obtain the optimum focus. (Refer to
Fig. 5-1-12.)
Holizontal line
Specified value : The image should be within 
±
 1.5 
°
 
           of the holizontal line.
θ
θ
±
1.5 
°
±
4%
±
4%
Adjustment value : 
±
4%
Focus adjustment
Aberration adjustment
DY tightening screw 
Centering adjustment
RV903
C909
CN902
IC901
F.B.T
W901
RV904
SOL901
Fig. 5-1-11.
Fig. 5-1-12.
Fig. 5-1-13.
VF-129 BOARD
5-22
1-4-4. Aberration Adjustment
Mode
VTR stop
Signal
Dot pattern
Specified Value
b1   2 
×
 a1
b2   0.8 
×
 a2
Adjusting method:
1)
Adjust the aberration adjustment ring so that the tracing of the
dot satisfies the specified value.
2)
If the centering becomes displaced here, perform the centering
adjustment from the beginning again.
1-4-5. Horizontal Amplitude Adjustment (VF-129 board)
Mode
Playback
Signal
Alignment tape :
For checking operation
(WR5-5CSP)
Monoscope section
Adjusting Element
C909 (SOL901)
Specified Value
10 ± 6%
Adjusting method:
1)
Rotate RV903, and adjust the top and bottom side of the
monoscope image to the top and bottom edges of the display.
2)
Rotate RV904 so that the brightness is the normal level.
3)
Solder or unsolder SOL901 pattern of the H size adjustment
capacitor (C909) to “short” or “open”, so that the horizontal
direction over scan becomes 10 ± 6% (Left and right totals).
100%
5%
5%
12.5%
12.5%
RV903
C909
CN902
IC901
F.B.T
W901
RV904
SOL901
Fig. 5-1-14.
Fig. 5-1-15.
SOL901
Open
Short
Size H
Small
Big
VF-129 BOARD
a2
a1
b1
b2
Page of 127
Display