DOWNLOAD Sony CCD-TRV66E / CCD-TRV77E Service Manual ↓ Size: 36.34 MB | Pages: 127 in PDF or view online for FREE

Model
CCD-TRV66E CCD-TRV77E
Pages
127
Size
36.34 MB
Type
PDF
Document
Service Manual
Brand
Device
Movie
File
ccd-trv66e-ccd-trv77e.pdf
Date

Sony CCD-TRV66E / CCD-TRV77E Service Manual ▷ View online

5-11
Address
6B
6C
6D
6E
6F
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
85
86
87
88
89
8A
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
9B
9C
9D
9E
9F
A0
A1
A2
Initial value
Remark
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
(Initialized data)
Address
A3
A4
A5
A6
A7
A8
A9
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
B5
B6
B7
B8
B9
BA
BB
BC
BD
BE
BF
C0
C1
C2
C3
C4
C5
C6
C7
C8
C9
CA
CB
CC
CD
CE
CF
D0
D1
D2
D3
D4
D5
D6
D7
D8
Initial value
80
84
77
98
7B
DC
80
89
70
Remark
Fixed data-1
(Initialized data)
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
(Initialized data)
VCO adj. (LCD)
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
(Initialized data)
Fixed data-2
Fixed data-1
(Initialized data)
Bright adj. (LCD)
Color adj. (LCD)
White balance adj. (LCD)
Contrast adj. (LCD)
D range adj. (LCD)
V-COM level adj. (LCD)
VCO adj. (LCD)
5-12
Address
D9
DA
DB
DC
DD
DE
DF
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
EA
EB
EC
ED
EE
EF
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
FB
FC
FD
FE
FF
Initial value
80
77
Remark
V-COM adj. (LCD)
Fixed data-1
Color adj. (LCD)
Fixed data-1
(Initialized data)
Fixed data-2
(Modified data, copy the data built in
the same model.)
Fixed data-1
Table. 5-1-4.
5-13
Address
38
39
3A
3B
3C
3D
5A
Data
1C
03
25
24
11
05
2A
Address
5B
5C
5D
5E
F8
F9
FA
Data
00
19
10
37
00
00
02
1-3. CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, Check that the
specified value of “28MHz Origin Oscillation Adjustment”, “Y OUT
level Adjustment” and “C OUT level Adjustment” of “VIDEO
SYSTEM ADJUSTMENT” are satisfied.
1. HALL Adjustment
For detecting the position of the lens iris, adjust the hall AMP gain
and offset.
Subject
Not required
Measurement Point
Display data of page 1
Measuring Instrument
Adjustment remote commander
Adjustment Page
F
Adjustment Address
47, 48
Specified Value
86 to 8A during IRIS OPEN
15 to 19 during IRIS CLOSE
Note :
Displayed data of page 1 of the adjustment remote commander.
1 : 00 : XX
Display data
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 01, set data: 6D, and press the PAUSE
button of the adjustment remote commander. (The HALL
adjustment is performed and the adjustment data is stored in
page: F, address: 47 and 48.)
3)
Select page: 6, address: 02, and check that the data is “01”.
4)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
Checking method:
1)
Select page: 0, address: 03, and set data: 03.
2)
Select page: 6, address: 01, set data: 01, and press the PAUSE
button.
3)
Select page: 1, and check that the display data (Note) during
IRIS OPEN satisfies the specified value.
4)
Select page: 6, address: 01, set data: 03, and press the PAUSE
button.
5)
Select page: 1, and check that the display data during IRIS
CLOSE satisfies the specified value.
Processing after Completing Adjustments
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
2)
Select page: 0, address: 01, and set data: 00.
3)
Select page: 0, address: 03, and set data: 00.
2. Flange Back Adjustment
The inner focus lens flange back adjustment is carried out
automatically. In whichever case, the focus will be deviated during
auto focusing/manual focusing.
2-1. Flange Back Adjustment(1)
Subject
Flange back adjustment chart
(2.0 m from the front of the lens)
(Luminance: 350 ± 50 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
38 to 3D, 5A to 5E, F8 to FA
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
4)
VIDEO LIGHT (CCD-TRV66E) ..................................... OFF
Adjusting method:
1)
Check that at both the zoom lens TELE end and WIDE end,
the center of the chart for the flange back adjustment and center
of the exposure screen coincide.
2)
Select page: 0, address: 01, and set data: 01.
3)
Check that the data of page: F, address:38 to 3D, 5A to 5E, F8
to FA is the initial value (See table below).
4)
Select page: 6, address: 02, and check that the data is “00”.
5)
Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: 6, address: 01, set data: 15, and press the PAUSE
button.
(The adjustment data will be automatically input to page: F,
addresses:38 to 3D, 5A to 5E, F8 to FA.)
7)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments
1)
Turn OFF the main power supply (8.4V).
2)
Perform “Flange Back Adjustment (2)”.
5-14
2-2. Flange Back Adjustment (2)
Perform this adjustment after performing “Flange Back Adjustment
(1)”.
Subject
Subject more than 500m away
(Subjects with clear contrast such as
buildings, etc.)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Adjustment Page
F
Adjustment Address
38 to 3D, 5A to 5E, F8 to FA
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
4)
VIDEO LIGHT (CCD-TRV66E) ..................................... OFF
Adjusting method:
1)
Set the zoom lens to the TELE end and expose a subject that is
more than 500 m away (subject with clear contrast such as
building, etc.). (Nearby subjects less than 500 m away should
not be in the screen.)
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 6, address: 02, and check that the data is “00”.
4)
Select page: 6, address: 01, set data: 13, and press the PAUSE
button of the adjustment remote commander.
5)
Place a ND filter on the lens so that the optimum image is
obtain.
6)
Select page: 6, address: 01, set data: 29, and press the PAUSE
button.
(The adjustment data will be automatically input to page: F,
addresses:38 to 3D, 5A to 5E, F8 to FA.)
7)
Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments
1)
Select page: 0, address: 01, and set data: 00.
2)
Turn OFF the main power supply (8.4V).
3)
Perform “Flange Back Check”.
3. Flange Back Check
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance : approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at the TELE end and WIDE end.
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
4)
VIDEO LIGHT (CCD-TRV66E) ..................................... OFF
Checking method:
1)
Place the Siemens star 2.0m from the front of the lens.
2)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
3)
Shoot the Siemens star with the zoom TELE end.
4)
Turn on the auto focus.
5)
Check that the lens is focused (Note).
6)
Select page: 6, address: 21, and set data: 10.
7)
Shoot the Siemens star with the zoom WIDE end.
8)
Observe the TV monitor and check that the lens is focused.
Note:
When the auto focus is ON, the lens can be checked if it is
focused or not by observing the data on the page 1 of the
adjustment remote commander.
1) Select page: 0, address: 03, and set data: 0F.
2) Page 1 shows the state of the focus.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Processing after Completing Adjustments
1)
Select page: 6, address: 21, and set data: 00.
2)
Select page: 0, address: 03, and set data: 00.
Page of 127
Display