6-7
CCD-TRV138/TRV238E/TRV338/TRV438E
1-2.
INITIALIZATION  OF  8,  A,  C,  D,  E,  F,  1F
PAGE  DATA
Note: If reading/writing data on pages 1F, set data: 01 to page: 0,
address: 10, and then select pages F. By this data setting,
the pages 1F can be selected.
After the data reading/writing finished, return the data on
page: 0, address: 10 to “00”.
1. Initializing the 8, A, C, D, E, F, 1F Page Data
Note 1: 
If “Initialization of Pages 8, A, C, D, E, F, 1F” is ex-
ecuted, all data on pages 8, A, C, D, E, F, 1F are initial-
ized. (Only an individual page cannot be initialized)
Note 2: If the 8, A, C, D, E, F, 1F page data has been initialized,
“Modification of 8, A, C, D, E, F, 1F Page Data” and all
adjustments need to be performed again.
Note 3: Check that the data of page: 0, address: 10 is “00”.
Note 4: NTSC model: CCD-TRV138/TRV338
PAL model: CCD-TRV238E/TRV438E
Adjusting Page
8
Adjusting Address
00 to FF
Adjusting Page
A
Adjusting Address
10 to FF
Adjusting Page
C
Adjusting Address
10 to FF
Adjusting Page
D
Adjusting Address
10 to 7F
Adjusting Page
E
Adjusting Address
00 to FF
Adjusting Page
F
Adjusting Address
10 to FF
Adjusting Page
1F
Adjusting Address
00 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
7
03
Set the following data.
00: NTSC model
80: PAL model
3
7
00
Set the following data.
2D: NTSC model
2F: PAL model
4
7
01
Set the following data, and
press PAUSE button.
2D: NTSC model
2F: PAL model
5
7
02
Check the data changes to
“01”.
6
2
00
29
7
2
01
29
Press PAUSE button.
8
Perform “Modification of 8,
A, C, D, E, F, 1F Page Data”
2. Modification of 8, A, C, D, E, F, 1F Page Data
If the 8, A, C, D, E, F, 1F page data has been initialized, change
the data of the “Fixed data-2” address shown in the following table
by manual input.
Modifying method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the
camcorder may not operate.
3) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after completing modification of 8, A, C, D, E, F, 1F
page data
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
Note: If the following symptoms occur after completing of the
“Modification of 8, A, C, D, E, F, 1F Page Data”, check
that the data of the “Fixed data-2” addresses of 8, A, C, D,
E, F, 1F page are same as those of the same model of the
same destination.
1) The power is shut off so that unit cannot operate.
3.
8 Page Table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, A, C, D, E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, A, C, D, E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to FF
Fixed data-1 (Initialized data)
6-8
CCD-TRV138/TRV238E/TRV338/TRV438E
4.
A Page Table
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, A, C, D, E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, A, C, D, E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
10 to 20
Fixed data-1 (Initialized data)
21
Fixed data-2
22 to 2B
Fixed data-1 (Initialized data)
2C
Fixed data-2
2D to 30
Fixed data-1 (Initialized data)
31
Fixed data-2
32 to 40
Fixed data-1 (Initialized data)
41
Fixed data-2
42 to 44
Fixed data-1 (Initialized data)
45
Fixed data-2
46 to 4B
Fixed data-1 (Initialized data)
4C
Fixed data-2
4D to 9C
Fixed data-1 (Initialized data)
9D
9E
9F
Fixed data-2
A0 to FF
Fixed data-1 (Initialized data)
5.
C Page Table (LCD Type: TYPE S)
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, A, C, D, E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, A, C, D, E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
10 to 13
Fixed data-1 (Initialized data)
14
00
00
Test mode
15
Fixed data-1 (Initialized data)
16
0B
0A
Switching position adj.
17
00
00
18
83
83
CAP FG offset adj.
19
30
30
AFC f
0
 adj.
1A
68
62
LINE OUT level adj.
1B
62
62
1C, 1D
Fixed data-1 (Initialized data)
1E
B4
D7
REC Y current adj.
1F
B4
D7
20 to 24
Fixed data-1 (Initialized data)
25
A0
A0
REC C/AFM current adj.
26 to 2E
Fixed data-1 (Initialized data)
2F
A6
A6
1.5 MHz deviation adj.
30
80
80
BPF f
0
 adj.
31 to 4F
Fixed data-1 (Initialized data)
50
67
79
LCD level adj. (VCO adj.)
51
79
67
52
84
84
LCD V-COM adj.
53 to 55
Fixed data-1 (Initialized data)
56
87
87
LCD White balance adj.
57
68
68
58
AF
AF
LCD level adj. (Contrast adj.)
59 to F3
Fixed data-1 (Initialized data)
F4
00
00
F5
00
00
F6
00
00
F7
00
00
F8
00
00
F9
00
00
Emergency memory
FA
00
00
FB
00
00
FC
00
00
FD
00
00
FE
00
00
FF
00
00
Ver. 1.1  2007.11
6-9
CCD-TRV138/TRV238E/TRV338/TRV438E
Ver. 1.1  2007.11
6.
C Page Table (LCD Type: TYPE SO)
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, A, C, D, E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, A, C, D, E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
10 to 13
Fixed data-1 (Initialized data)
14
00
00
Test mode
15
Fixed data-1 (Initialized data)
16
0B
0A
17
00
00
Switching position adj.
18
83
83
CAP FG offset adj.
19
30
30
AFC f
0
 adj.
1A
68
62
1B
62
62
LINE OUT level adj.
1C, 1D
Fixed data-1 (Initialized data)
1E
B4
D7
1F
B4
D7
REC Y current adj.
20 to 24
Fixed data-1 (Initialized data)
25
A0
A0
REC C/AFM current adj.
26 to 2E
Fixed data-1 (Initialized data)
2F
A6
A6
1.5 MHz deviation adj.
30
80
80
BPF f
0
 adj.
31 to 4D
Fixed data-1 (Initialized data)
4E
4F
Fixed data-2
50
85
8F
51
8F
85
LCD level adj. (VCO adj.)
52
88
84
LCD V-COM adj.
53
8C
89
LCD level adj. (RGB AMP adj.)
54
55
Fixed data-2
56
7B
73
57
6B
6E
LCD White balance adj.
58
21
21
LCD level adj. (Contrast adj.)
59
Fixed data-2
5A
Fixed data-1 (Initialized data)
5B
C0
C0
LCD level adj. (PSIG black adj.)
5C
5D
Fixed data-2
5E
5F to 63
Fixed data-1 (Initialized data)
64
Fixed data-2
65
Fixed data-1 (Initialized data)
66
67
Fixed data-2
68
69 to 70
Fixed data-1 (Initialized data)
71
Fixed data-2
Address
Initial value
Remark
72 to 74
Fixed data-1 (Initialized data)
75
76
Fixed data-2
77 to 93
Fixed data-1 (Initialized data)
94
95
Fixed data-2
96 to E3
Fixed data-1 (Initialized data)
E4
Fixed data-2
E5
Fixed data-1 (Initialized data)
E6
Fixed data-2
E7
Fixed data-1 (Initialized data)
E8
Fixed data-2
E9 to F3
Fixed data-1 (Initialized data)
F4
00
00
F5
00
00
F6
00
00
F7
00
00
F8
00
00
F9
00
00
FA
00
00
Emergency memory
FB
00
00
FC
00
00
FD
00
00
FE
00
00
FF
00
00
6-10
CCD-TRV138/TRV238E/TRV338/TRV438E
7. D Page Table
Note 1: 
Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, A, C, D, E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, A, C, D, E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
10
00
00
Test mode
11, 12
Fixed data-1 (Initialized data)
13
Fixed data-2
14 to 21
Fixed data-1 (Initialized data)
22
23
24
Fixed data-2
25
26
27 to 29
Fixed data-1 (Initialized data)
2A
2B
Fixed data-2
2C to 35
Fixed data-1 (Initialized data)
36
37
Fixed data-2
38
39
Fixed data-1 (Initialized data)
3A
3B
Fixed data-2
3C to 55
Fixed data-1 (Initialized data)
56
Fixed data-2
57
Fixed data-1 (Initialized data)
58
59
Fixed data-2
5A to 6E
Fixed data-1 (Initialized data)
6F
Fixed data-2
70 to 7F
Fixed data-1 (Initialized data)
8. E Page Table
Note 1: 
Check that the data of page: 0, address: 10 is “00”.
Note 2: Fixed data-1: Initialized data. (Refer to “1. Initializing
the 8, A, C, D, E, F, 1F Page Data”)
Fixed data-2: Modified data. (Refer to “2. Modification
of 8, A, C, D, E, F, 1F Page Data”)
Address
Initial value
Remark
NTSC PAL
00 to 30
Fixed data-1 (Initialized data)
31
Fixed data-2
32 to BF
Fixed data-1 (Initialized data)
C0
Fixed data-2
C1 to FF
Fixed data-1 (Initialized data)
Ver. 1.1  2007.11
Page of 52
Display

Click on the first or last page to see other CCD-TRV138 / CCD-TRV238E / CCD-TRV338 / CCD-TRV438E (serv.man2) service manuals if exist.