DOWNLOAD Sony CCD-TRV138 / CCD-TRV238E / CCD-TRV338 / CCD-TRV438E (serv.man2) Service Manual ↓ Size: 732.78 KB | Pages: 52 in PDF or view online for FREE

Model
CCD-TRV138 CCD-TRV238E CCD-TRV338 CCD-TRV438E (serv.man2)
Pages
52
Size
732.78 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
ccd-trv138-ccd-trv238e-ccd-trv338-ccd-trv438e-sm2.pdf
Date

Sony CCD-TRV138 / CCD-TRV238E / CCD-TRV338 / CCD-TRV438E (serv.man2) Service Manual ▷ View online

6-15
CCD-TRV138/TRV238E/TRV338/TRV438E
4. Flange Back Check
Mode
CAMERA
Subject
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Measurement Point
Check operation on monitor TV
Measuring Instrument
Specified value
Focused at the TELE end and WIDE
end
Note 1: Check that the data of page: 0, address: 10 is “00”.
Switch setting:
1) NIGHTSHOT PLUS ........................................................ OFF
2) DISPLAY (Menu setting) ................................................ LCD
Note 2: When the auto focus is ON, the lens can be checked if it
is focused or not by observing the data on the page: 1 of
the adjusting remote commander.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Checking method:
Order Page Address Data
Procedure
1
Place the Siemens star 2.0 m
from the front of the lens.
2
To open the IRIS, decrease
the luminous intensity to the
Siemens star up to a point
before noise appear on the
image.
3
6
40
01
4
6
41
01
5
Shoot the Siemens star with
the zoom TELE end.
6
Turn on the auto focus.
7
0
03
0F
8
1
Check that the lens is
focused. (Note 2)
9
6
21
10
10
Shoot the Siemens star with
the zoom WIDE end.
11
Observe the TV monitor and
check that the lens is
focused.
Processing after completing adjustment:
Order Page Address Data
Procedure
1
6
21
00
2
6
40
00
3
6
41
00
4
0
03
00
6-16
CCD-TRV138/TRV238E/TRV338/TRV438E
5. Optical Axis Adjustment
Correct a deviation of optical axis between the lens and the CCD
imager.
If deviated, the screen center will be shifted when the lens is
zoomed from TELE end to WIDE end.
Subject
Siemens Star
Measurement Point
Check operation on monitor TV
Measuring Instrument
Adjustment Page
F
Adjustment Address
5A
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: “Flange Back Adjustment” must be already finished.
Switch setting:
1) DIGITAL ZOOM (Menu setting) .................................... OFF
2) STEADYSHOT (Menu setting)
(CCD-TRV338/TRV438E only) ...................................... OFF
3) DISPLAY (Menu setting) ................................................ LCD
Preparation for adjustment:
1) Play a monoscope portion of the System Check tape (WR5-
5NSP (NTSC) or WR5-5CSP (PAL)).
2) Stick the optical axis deviation specification frame to the moni-
tor screen so that the center of monoscope coincides with the
center of specification frame.
3) Select the CAMERA mode.
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: F, address: 5A, and set data: 00, then press the
PAUSE button on the adjusting remote commander.
3) Place the Siemens Star at 2 m position away from the lens.
4) Shoot the Siemens Star with the zoom at TELE end.
5) Change the lens direction so that the center of Siemens Star
coincides with the center of optical axis deviation specifica-
tion frame.
6) Shoot the Siemens Star with the zoom at WIDE end.
7) Check on the monitor TV which area the center of Siemens
Star exists of the optical axis deviation specification frame.
At this time, measure the amount of deviation “L1” (distance
from the center of Siemens Star to the center of optical axis
deviation specification frame).
8) From the following table, read correction data according to
the area.
0
180
90
67.5
22.5
337.5
292.5
247.5
202.5
157.5
112.5
8
4
5
7
1
6
2
3
270
Fig. 6-1-8
Area
1
2
3
4
5
6
7
8
Deviation Phase
22.6
° to 67.5°
67.6
° to 112.5°
112.6
° to 157.5°
157.6
° to 202.5°
202.6
° to 247.5°
247.6
° to 292.5°
292.6
° to 337.5°
337.6
° to 22.5°
Correction Data
01
02
03
04
05
06
07
08
9) Select page: F, address: 5A, and set correction data, then press
the PAUSE button on the adjusting remote commander.
10) Shoot the Siemens Star with the zoom at TELE end.
11) Change the lens direction so that the center of Siemens Star
coincides with the center of optical axis deviation specifica-
tion frame.
12) Shoot the Siemens Star with the zoom at WIDE end.
13) Measure the amount of deviation “L2” (distance from the cen-
ter of Siemens Star to the center of optical axis deviation speci-
fication frame).
14) Compare L1 and L2, and make sure that the L2 is smaller than
L1.
If large, select page: F, address: 5A, and set data: 00, then
press the PAUSE button on the adjusting remote commander.
Processing after completion of adjustment:
1) Select page: 0, address: 01, and set data: 00.
6-17
CCD-TRV138/TRV238E/TRV338/TRV438E
Check on the oscilloscope
1. Horizontal period
A=B
C=D
A
B
C
D
E=F
V
E
F
Color bar chart picture frame
Monitor TV picture frame
Fig. 6-1-9
2. Vertical period
Fig. 6-1-10
Check on the monitor TV (Underscanned mode)
Fig. 6-1-11
6. Picture Frame Setting
Mode
CAMERA
Subject
Color bar chart
(Color reproduction adjustment
frame)
(1 m (PTB-450) or 40 cm (PTB-
1450) from the front of lens)
Measurement Point
Video terminal of A/V OUT jack
(75 
Ω terminated)
Measuring Instrument
Oscilloscope and monitor TV
Specified Value
A=B, C=D, E=F
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Perform “Flange Back Adjustment” and “Optical Axis
Adjustment” before this adjustment.
Switch setting:
1) DIGITAL ZOOM (Menu setting) .................................... OFF
2) STEADYSHOT (Menu setting)
(CCD-TRV338/TRV438E only) ...................................... OFF
3) DISPLAY (Menu setting) ................................................ LCD
Setting method:
1) Select page: 6, address: 48, and set data: 01.
2) Adjust the zoom and the camera direction, and set to the speci-
fied position.
3) Mark the position of the picture frame on the monitor display,
and adjust the picture frame to this position in following ad-
justments using “Color reproduction adjustment frame”.
Processing after completing camera system adjustments:
1) Select page: 6, address: 48, and set data: 00.
6-18
CCD-TRV138/TRV238E/TRV338/TRV438E
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Burst
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Burst
7. Color Reproduction Adjustment
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
Mode
CAMERA
Subject
Color bar chart
(Color reproduction adjustment
frame)
Measurement Point
Video terminal of A/V OUT jack
(75 
Ω terminated)
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
33, 35, 3A, 3B
Specified Value
All color luminance points should
settle within each color reproduction
frame.
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Perform “Flange Back Adjustment” before this adjust-
ment.
Note 3: NTSC model: CCD-TRV138/TRV338
PAL model: CCD-TRV238E/TRV438E
Switch setting:
1) NIGHTSHOT PLUS ........................................................ OFF
2) DIGITAL ZOOM (Menu setting) .................................... OFF
3) STEADYSHOT (Menu setting)
(CCD-TRV338/TRV438E only) ...................................... OFF
4) DISPLAY (Menu setting) ................................................ LCD
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
48
01
3
6
9D
Set the following data.
68: NTSC model
67: PAL model
4
6
01
3D
Press PAUSE button.
5
F
80
Set the following data, and
press PAUSE button.
77: NTSC model
F7: PAL model
6
Adjust the GAIN and
PHASE of the vectorscope,
and set to the burst lumi-
nance point to the burst
position of color reproduc-
tion frame.
7
F
Change the data and settle
each color luminance point in
each color reproduction
frame. (Note 4)
Note 4: Be sure to press the PAUSE button of the adjusting re-
mote commander before changing the addresses. If not,
the new data will not be written to the memory.
Fig. 6-1-12
NTSC model
PAL model
33
35
3A
3B
Processing after completing adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
48
00
3
6
9D
00
4
0
01
00
Page of 52
Display