DOWNLOAD Sony CCD-TRV138 / CCD-TRV238E / CCD-TRV338 / CCD-TRV438E (serv.man2) Service Manual ↓ Size: 732.78 KB | Pages: 52 in PDF or view online for FREE

Model
CCD-TRV138 CCD-TRV238E CCD-TRV338 CCD-TRV438E (serv.man2)
Pages
52
Size
732.78 KB
Type
PDF
Document
Service Manual
Brand
Device
Movie / SECTION 6 ADJUSTMENTS
File
ccd-trv138-ccd-trv238e-ccd-trv338-ccd-trv438e-sm2.pdf
Date

Sony CCD-TRV138 / CCD-TRV238E / CCD-TRV338 / CCD-TRV438E (serv.man2) Service Manual ▷ View online

6-31
CCD-TRV138/TRV238E/TRV338/TRV438E
3-2. SYSTEM CONTROL SYSTEM ADJUSTMENTS
1. Initialization of 8, A, C, D, E, F, 1F Page Data
If the 8, A, C, D, E, F, 1F page data is erased due to some reason,
perform “1-2. INITIALIZATION OF 8, A, C, D, E, F, 1F PAGE
DATA” of “6-1. CAMERA SECTION ADJUSTMENTS”.
3-3. SERVO SYSTEM ADJUSTMENTS
Before perform the servo system adjustments, check that the speci-
fied values of “28 MHz Origin Oscillation Adjustment” of “VIDEO
SYSTEM ADJUSTMENTS” is satisfied.
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
1. CAP FG Offset Adjustment (VC-341 Board)
RadarW
RadarW
RadarW
RadarW
RadarW
Set the CAP FG signal duty cycle to 50% to establish an appropri-
ate capstan servo. If deviated, the uneven rotation of capstan and
noise can occur in the playback mode.
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Measurement Point
Displayed data of page: 3, address: 03
Measuring Instrument
Adjusting remote commander
Adjustment Page
C
Adjustment Address
18
Specified value
The data of page: 3, address: 03 is “00”
Note 1: Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compartment
without inserting cassette.
2
0
01
01
3
3
01
81
Press PAUSE button.
4
3
02
Check the data changes to
“00”.
5
3
03
Check that the data is “00”.
(Note 2)
6
0
01
00
Note 2: If the data is other than “00”, adjustment has errors.
For the error contents, see the following table.
Data of page: 3,
Error contents
address: 03
01
Adjustment time out (Note 3)
10
Mechanism mode error (For example, the
adjustment is performed in the mode except
for VTR stop mode.)
Note 3: In case of the adjustment time out, perform readjustment
by the method given below.
Ver. 1.1  2007.11
Readjustment method:
Order Page Address Data
Procedure
1
3
01
81
Press PAUSE button.
2
Wait for 5 seconds.
3
C
18
90
Press PAUSE button.
4
3
02
Check the data changes to
“00”.
5
3
03
Check the data.
00: Normal
01: Go to step 7.
6
C
18
Check the data.
90: Go to step 7.
Other than 90: Adjustment end.
7
3
01
81
8
Wait for 5 seconds.
9
C
18
70
Press PAUSE button.
10
3
02
Check the data changes to
“00”.
11
3
03
Check the data.
00: Normal
01: Perform adjustment
from the beginning.
(Note 4)
12
C
18
Check the data.
70: Perform adjustment from
the beginning. (Note 4)
Other than 70: Adjustment end.
Note 4: NG if an error occurred again.
6-32
CCD-TRV138/TRV238E/TRV338/TRV438E
2. Switching Position Adjustment (VC-341 Board)
If deviated in this case cause switching noise or jitter on the played
back screen.
Mode
VTR playback
Signal
Alignment tape:
For tracking adjustment
(WR5-1NU (NTSC))
(WR5-1CU (PAL))
Measurement Point
CH1: SWU (Pin 5 of CN007)
CH2: PB RF (Pin 9 of CN007)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
16, 17
Specified value
t1 = 0 
± 10 µsec
Note 1: Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
3
92
Set the bit value of bit 2 to “1”,
and press PAUSE button.
(Note 2)
3
C
16
Change the data and minimize
“t1”. (Coarse adjustment)
4
C
16
Press PAUSE button.
5
C
17
Change the data and adjust so
that the switching position (t1)
becomes specified value. (Fine
adjustment)
6
C
17
Press PAUSE button.
7
3
92
Set the bit value of bit 2 to “0”,
and press PAUSE button.
(Note 2)
8
0
01
00
Note 2: For the bit values, refer to  “6-4. SERVICE MODE”, “4-
3. 3. Bit Value Discrimination”.
Fig. 6-3-3
CH1
CH2
Enlargement
t1=0 
± 10 µsec
CH1
CH2
6-33
CCD-TRV138/TRV238E/TRV338/TRV438E
3-4.
VIDEO SYSTEM ADJUSTMENTS
Before perform the video system adjustments, check that the data
of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
Video system adjustments must be performed in the following or-
der.
Adjusting procedure:
1. 28 MHz origin oscillation adjustment
2. AFC f
0
 adjustment
3. LINE OUT level adjustment
4. REC Y current adjustment
5. REC C/AFM current adjustment
1. 28 MHz Origin Oscillation Adjustment
(VC-341 Board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Measurement Point
Pin qa of IC151
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified value
f = 14318181 
± 68 Hz (NTSC model)
f = 14187500 
± 54 Hz (PAL model)
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Refer to “2. DISASSEMBLY”, when opening the VC-
341 board.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
F
10
Change the data and set the
frequency (f) to the specified
value.
3
F
10
Press PAUSE button.
4
0
01
00
Fig. 6-3-4
2. AFC f
0
 Adjustment (VC-341 Board) 
RadarW
RadarW
RadarW
RadarW
RadarW
Adjust the pull-in range of A/D converted clock generator during
playback.
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Measurement Point
Displayed data of page: 3, address: 03
Measuring Instrument
Adjusting remote commander
Adjustment Page
C
Adjustment Address
19
Specified value
The data of page: 3, address: 03 is “00”
Note 1: Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compartment
without inserting cassette.
2
0
01
01
3
3
01
82
Press PAUSE button.
4
3
02
Check the data changes to
“00”.
5
3
03
Check that the data is “00”.
(Note 2)
6
0
01
00
Note 2: If the data is other than“00”, adjustment has errors.
IC151
13
12 11 1
36
25
24
48
37
Measurement
Point
VC-341 BOARD (SIDE B)
6-34
CCD-TRV138/TRV238E/TRV338/TRV438E
3. LINE OUT Level Adjustment (VC-341 Board)
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Measurement Point
Video terminal of A/V OUT jack
(75 
Ω terminated)
Measuring Instrument
Oscilloscope
Adjustment Page
C
Adjustment Address
1A, 1B
Specified value
Sync level:
A = 286 
± 5 mVp-p (NTSC)
A = 300 
± 5 mVp-p (PAL)
Burst level:
B = 286 
± 5 mVp-p (NTSC)
B = 300 
± 5 mVp-p (PAL)
Note:  Check that the data of page: 0, address: 10 is “00”.
Adjustment method:
Order Page Address Data
Procedure
1
0
01
01
2
D
10
02
Press PAUSE button.
3
C
1A
Change the data and set the
SYNC level (A) to the
specified value.
4
C
1A
Press PAUSE button.
5
C
1B
Change the data and set the
burst level (B) to the specified
value.
6
C
1B
Press PAUSE button.
7
D
10
00
Press PAUSE button.
Fig. 6-3-5
H
B
A
Page of 52
Display

Click on the first or last page to see other CCD-TRV138 / CCD-TRV238E / CCD-TRV338 / CCD-TRV438E (serv.man2) service manuals if exist.