Movie / SECTION 6 ADJUSTMENTS
File
ccd-trv138-ccd-trv238e-ccd-trv338-ccd-trv438e-sm2.pdf
Date

Sony CCD-TRV138 / CCD-TRV238E / CCD-TRV338 / CCD-TRV438E (serv.man2) Service Manual ▷ View online

6-39
CCD-TRV138/TRV238E/TRV338/TRV438E
6-4. SERVICE MODE
4-1.
ADJUSTMENT REMOTE COMMANDER
The adjustment remote commander is used for changing the cal-
culation coefficient in signal processing, EVR data, etc. The ad-
justment remote commander performs bi-directional
communication with the unit using the remote commander signal
line (LANC). The resultant data of this bi-directional communica-
tion is written in the non-volatile memory.
1.
Using the Adjustment Remote Commander
1) Connect the adjustment remote commander to CN007 of VC-
341 board via I/F unit for LANC control (J-6082-521-A) and
CPC jig connector (J-6082-539-A).
2) Set the HOLD switch of the adjustment remote commander to
“HOLD” (SERVICE position). If it has been properly con-
nected, the LCD on the adjustment remote commander will
display as shown in Fig. 6-4-1.
Fig. 6-4-1
3) Operate the adjustment remote commander as follows.
• Changing the page
The page increases when the EDIT SEARCH+ button is
pressed, and decreases when the EDIT SEARCH– button is
pressed. There are altogether 16 pages, from 0 to F.
• Changing the address
The address increases when the FF (M) button is pressed,
and decreases when the REW (m) button is pressed. There
are altogether 256 addresses, from 00 to FF.
• Changing the data (Data setting)
The data increases when the PLAY (N) button is pressed,
and decreases when the STOP (x) button is pressed. There
are altogether 256 data, from 00 to FF.
• Writing the adjustment data
The PAUSE button must be pressed to write the adjustment
data in the nonvolatile memory. (The new adjusting data will
not be recorded in the nonvolatile memory if this step is not
performed)
4) After completing all adjustments, turn off the main power sup-
ply (8.4 V) once.
Page
Data
Address
Hexadecimal
notation
LCD Display
Decimal notation
conversion value
0 1 2 3 4 5 6 7 8 9 A B C D E F
0 1 2 3 4 5 6 7 8 9 A b c d E F
0 1 2 3 4 5 6 7 8 9 10 1112 13 14 15
2. Precautions Upon Using
the Adjustment Remote Commander
Mishandling of the adjustment remote commander may erase the
correct adjustment data at times. To prevent this, it is recommended
that all adjustment data be noted down before beginning adjust-
ments and new adjustment data after each adjustment.
6-40
CCD-TRV138/TRV238E/TRV338/TRV438E
Hexadecimal-decimal Conversion Table
Lower digit of
hexadecimal 
Upper digit 
of hexadecimal
0
1
2
3
4
5
6
7
8
9
A
(
A
)
B
(
b
)
C
(
c
)
D
(
d
)
E
(
E
)
F
(
F
)
0
1
2
3
4
5
6
7
8
9
A (
A
)
B (
b
)
C (
c
)
D (
d
)
E (
E
)
F (
F
)
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
77
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
174
159
175
160
161
162
163
164
165
166
167
168
169
170
171
172
173
177
176
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
0
1
Note:
The characters shown in the parenthesis (  ) shown the display on the adjustment remote commander.
(Example) If the DDS display or the adjustment remote commander shows BD (
bd
);
Because the upper digit of the adjustment number is B (
b
), and the lower digit is D (
d
), the meeting point 
“189” of 1 and 2 in the above table is the corresponding decimal number.
0
2
4-2.
DATA PROCESS
The calculation of the DDS display and the adjustment remote
commander display data (hexadecimal notation) are required for
obtaining the adjustment data of some adjustment items. In this
case, after converting the hexadecimal notation to decimal nota-
tion, calculate and convert the result to hexadecimal notation, and
use it as the adjustment data. Indicates the hexadecimal-decimal
conversion table.
Table 6-4-1
6-41
CCD-TRV138/TRV238E/TRV338/TRV438E
4-3.
SERVICE MODE
Additional note on adjustment
Note: 
After the completion of the all adjustments, cancel the ser-
vice mode by either of the following ways.
1) After data on page: D and C is restored, press the RE-
SET button and unplug the main power supply. (In this
case, date and time and menu setting have been set by
users are canceled. Perform resetting)
2) After data on page: D and C is restored, select page: 0,
address: 01, and return the data to 00. And when data
on page: 2 are changed, return data to the original con-
dition.
1. Setting the Test Mode
Page C
Address 14
Data
Function
00
Normal
01
Test mode
Various emergency prohibitions and releases
Drum emergency, capstan emergency, loading motor
emergency, reel emergency, tape top and end, DEW
detection
Page D
Address 10
Data
Function
00
Normal
01
Forced camera power ON
02
Forced VTR power ON
03
Forced camera + VTR power ON
• Before setting the data , select page: 0, address: 01, and set data:
01.
• For page D and C, the data set will be recorded in the non-
volatile memory by pressing the PAUSE button of the adjust-
ment remote commander. In this case, take note that the test
mode will not be exited even when the main power is turned off
(8.4 Vdc).
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjust-
ment remote commander. And select page: 0, address: 01, and
set data: 00.
6-42
CCD-TRV138/TRV238E/TRV338/TRV438E
2. Emergency Memory Address
Page C
Address F4 to FF
Address
Contents
F4
1st EMG code
F6
Upper: MSW code when the mechanism starts
shifting the 1st time
Lower: MSW code when the 1st emergency occurs
F7
Lower: Target MSW code of the 1st emergency
occurs
F8
2nd EMG code
FA
Upper: MSW code when the mechanism starts
shifting the 2nd time
Lower: MSW code when the 2nd emergency occurs
FB
Lower: Target MSW code of the 2nd emergency
occurs
FC
Last EMG code
FE
Upper: MSW code when the mechanism starts
shifting the last time
Lower: MSW code when the last emergency occurs
FF
Lower: Target MSW code of the last emergency
occurs
When there are no emergency, data 00 will be written in the above
addresses (F4 to FF). When the first emergency occurs, the data
corresponding to the emergency will be written in the address (F4
to F7) for this first emergency. In the same way, when the second
emergency occurs, the data corresponding to the emergency will
be written in the address (F8 to FB) for this second emergency.
The data corresponding to the emergency occurring the last will
be written in the address (FC to FF) for this last emergency.
Therefore the data of addresses FC to FF are renewed each time
an emergency occurs.
Note: After completing adjustments, be sure to initialize the data
of address F4 to FF to “00”.
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
3
01
37
Press PAUSE button.
3
3
02
Check the data changes to “00”.
4
0
01
00
2-1.
EMG Code (Emergency Code)
The codes shown in the following table which correspond to er-
rors that occur are recorded in addresses F4, F8, and FC.
Code
Type of Emergency
00
No error
10
Loading motor time-out during load
11
Loading motor time-out during unload
20
T reel emergency (reel slack) during unloading
21
S reel emergency (reel slack) during unloading
22
T reel emergency
23
S reel emergency
30
FG emergency at the start up of the capstan
31
FG emergency during the normal rotation of the
capstan
40
FG emergency at the start up of the drum
41
PG emergency at the start up of the drum
42
FG emergency during the normal rotation of the
drum
43
PG emergency during the normal rotation of the
drum
44
Phase emergency during the normal rotation of the
drum
Page of 52
Display