21
1-5-5.  Changer Mecha Test (Changer Mecha Test)
 Diag
Category: 
 Diag
Category: Changer Mecha Test
DISC Sensor 
: [0]
TABLE Sensor  : [0:0:0:0]
LOAD Sensor 
: <Released>
DOOR Sensor 
: <Closed>
Initialize first, please.
[1] Popper 
Up/Down
[OPEN/CLOSE] Open/Close
[PREV] Turn 
Left
[NEXT] Turn 
Right
[FR] 
Turn Around Left
[FF] 
Turn Around Right
[PLAY] Chuck/Unchuck
HELP: [UP] [DOWN] [ENT] [RET]
Changer Mecha Test
[0] Initialize
(Screen 1)
(Screen 2)
Mechanism cannot be operated if it does not initialize it when the 
message of “Initialize fi rst, please.” is displayed.
The message of “Initialize fi rst, please.” disappears when initial-
ization is done.
The sensor display is always updated.
DISC Sensor: “0” or “1” is displayed.
TABLE Sensor: “0” or “1” is displayed.
LOAD Sensor:  The state is displayed (“Released”, “Release 
↔ 
Lock”, “Table Locked” or “Chucked”).
DOOR Sensor: The state is displayed (“Opened”, “Moving”, 
“Closed”, “Opened/Popper Up”, “Opened/Popper 
Moving” or “Opened/Popper Down”).
Mechanism can be operated by pressing the button of the corre-
sponding remote commander.
[0] 
The initialization of mechanism is executed.
[1] 
The door opens and pop up when the door 
closes. The pop up when the door opens and 
not pop up. The pop down when the door 
opens and pop up.
[OPEN/CLOSE] 
The door is opened or closed.
[PREV 
.
One slot is rotated to the left (when the door 
closes, it opens) (when the chucking, it chuck 
down).
[NEXT 
>
One slot is rotated to the right (when the door 
closes, it opens) (when the chucking, it chuck 
down).
[
m
One rotation to the left (when the door closes, 
it opens) (when the chucking, it chuck down).
[
M
One rotation to the right (when the door 
closes, it opens) (when the chucking, it chuck 
down).
[
N
Disc at the position of the drive is downed in 
the chuck or the chucking.
1-6. Log
Operation:
[1] 
Moves to the Error Log screen.
[2] 
Moves to the Command Log screen.
[
M
]/[
m
Moves the cursor.
[
3
Moves to the item selected with the cursor.
[RETURN]  Returns to the top menu of the service mode.
 Select Log
[2] Command Log
HELP : [DOWN] [ENT] [RET] [(NUM)]
[1] Error Log
The page is changes if the [
<
]/[
,
] buttons are pressed on the 
screen where the log was displayed.
Press the [RETURN] button to return from the log display.
1-7. Factory Initialize
Data base, remote control mode, password and other setting value 
are initialized, Gracenote relation fi le is deleted.
Operation:
Press the [
3
] button in this screen when restoring the set to its 
factory settings.
[
3
Initialize the set to its factory settings.
[RETURN]  Return to the top menu of the service mode.
 Factory Initialize
[ENT] Start Initialize
[RET] Return to Top Menu
HELP : [ENT] [RET]
BDP-CX960
22
1-8. Ship Mode
Changer Mechanism is changed to the ship mode.
Eject all disc in the table before it enters this mode.
Operation:
Press the [
3
] button in this screen when setting the chucking 
down, turn table free and door closed, and turn the power off.
[
3
Changes to the ship mode.
[RETURN]  Return to the top menu of the service mode
 Ship Mode
[ENT] Set to the Ship Mode
[RET] Return to Top Menu
HELP : [ENT] [RET]
1-9. Network
Display of network information.
Operation:
[
<
]/[
,
]  Selects the Ifconfi g or Ping.
[
3
Executes the information display.
[
M
Returns to selection of test category.
 
Moves the cursor.
[
m
Moves the cursor.
[RETURN]  Return to the top menu of the service mode
 Network
Test: Ping
HELP: [ENT]: InputIP [DOWN] [LEFT]
Ifconfig
Test:  Ifconfig
Network
[START]
Ping
Ping To  :
(Screen 1)
(Screen 2)
Ifconfi g: Display of network information
Ping: IP that transmits ping is set and it transmits.
Ping input display
Test:  Ifconfig
Network
[START]
[ENT] : 
Release
[RET] : 
Release
[LEFT]  : Ifconfig Test
[(NUM)] : 
‘0-9’
[TIME] : 
‘.’
[CLEAR]  : Back Space
Ping
Ping To  :
[ENT]/[RET] 
Input Ping is released.
[LEFT] 
Select the Ifconfi g.
[(NUM)]/[TIME] IP address for Ping is input.
[CLEAR] 
Back space of one input IP address.
1-10. System 
Information
Display of system information.
Operation:
[
3
] Measures 
ΔIOP of the drive (takes a few seconds: 
1time only)
[RETURN]  Returns to the top menu of the service mode
Displayed contents: 
Model name: Model
Destination: Dest
IP address: IP
Mac address: Mac
CPU version: CPU 
← [Firm Version] [Generation Version]
NBL version: NBL
Kernel version: Kernel
Host version: Host 
← [Host Version] [Release Version]
Optical disc drive: Drive 
← [Model] [Firm Revision] 
 [Serial 
Number]
Drive usage time: LDTime 
← [Media]: [LDTime]/[ΔIOP]/
 
ΔIOP/ΔIOP
ΔIOP temperature measurement : dIOP_TEMP
IFCon version: IFCon 
← [Ifcon Version]
IFCon Firm date: FirmDate
Set temperature: Temp 
← [°C]
 System Information
Model
: BDM1G-HF
Dest
: UC
IP
: 172.16.19.3
Mac
: xx:xx:xx:xx:xx:xx
CPU
: E5.013.0_pre[F030]
NBL
: BDP3G 3.5.0
Kernel
: BDP3G-3.4.0
Host
: 15.2.010
20090616000D00
Drive
: BPD210 1.00 @BDM8800024&__20
LDTime
: BD
: [    12:57] / [      0]
DVD
: [    14:03] / [      0]
CD
: [    25:54] / [      0]
dIOP_TEMP:  [      0]
Ifcon
: 1.04
FirmDate: 06/16
Temp
: 34 [degC]
[RET]: TopMenu 
BDP-CX960
23
2.  ERROR  CODE  LIST
Major category 
Category code
Details of cause 
and error contents
Display 
on FL 
tube
Error information displayed in error 
log
Corrective action at service 
center
Category
err_code
err_info 
(4byte length)
ERRLOG_
CATEGORY_
THERMO
Shutdown due to 
temperature rise of 
the set
FAN ERR
0x05
0x01
Check the ambient temperature of 
the set
FAN is defective
FAN ERR
0x02
Replace the fan
ERRLOG_
CATEGORY_
NVRAM
NAND Error
E7001
0x07
0x01
Reboot the set, and if the error 
recurs or if the set malfunctions, 
perform the service. (When the error 
persists though NVRAM is forcibly 
initialized, replace the NAND. All the 
data in NVRAM including the setting 
information are initialized)
E7002
0x02
E7003
0x03
E7004
0x04
E7005
0x05
Reboot the set for automatic recov-
ery. If the error recurs, perform the 
service. (When the error persists 
though NVRAM is forcibly initialized, 
replace the NAND. All the data in 
NVRAM including the setting infor-
mation are initialized)
E7006
0x06
E7007
0x07
E7008
0x08
E7009
0x09
E7010
0x0A
E7011
0x0B
NAND 
(SdmRegistry) 
Error
E7101
0x65
Reboot the set and if the error oc-
curs, perform the service. (Replace 
the NAND because it reached the 
life)
E7102
0x66
E7103
0x67
E7104
0x68
E7105
0x69
N/A
NAND (Database) 
Error
E9101
No error log is recorded.
Reboot the set, and if the error 
recurs, perform the service. (When 
the error persists though the “Fac-
tory Initialize” is done, replace the 
NAND. All the data including setting 
information are initialized)
E9102
E9103
E9104
ERRLOG_
CATEGORY_
MECHA
Mechanism 
error that cannot be 
specifi ed
E8000
0x09
0x00
Mechanical error. Check the each 
motion and perform the service.
Fails the door 
close in initializing 
mechanism
E8001
0x01
Check the door mechanism. (Gear 
alignment, switch condition, Assem-
bly of the door guide rail) 
Makes an error 
while the table is 
operating
E8002
0x02
Check the sensor alignment. (espe-
cially the table sensor alignment)/
Check the table mechanism. (As-
sembly of gears, teeth of Table (400) 
for sensor)
Makes an error 
while the loading is 
operating
E8003
0x03
Check the loading mechanism and 
perform the service.
Makes an error 
while Popper is 
operating
E8004
0x04
Check the pop-up mechanism. 
(especially POP-UP lever alignment) 
And check the door mechanism. 
(Pop-Up is common mechanism with 
door’s)
N/A
Drive Tray Error
E8902
No error log is recorded.
Reboot the set, and if the error 
recurs, perform the service. (Check 
optical drive)
BDP-CX960
24
3.  CONFIRMATION  ITEM
3-1.  Playback Operation Confi rmation
3-1-1. Test Disc
Part No.
Description
Layer
J-6090-199-A
BLX-104
Single Layer
J-6090-200-A
BLX-204
Dual Layer
3-702-101-01
CD (YEDS-18)
J-6090-088-A
HLX-504
Single Layer (NTSC)
J-6090-089-A
HLX-505
Dual Layer (NTSC)
J-6090-077-A
HLX-506
Single Layer (PAL)
J-6090-078-A
HLX-507
Dual Layer (PAL)
Note: Refer to the service manual of BDP-BX1/S350 (Part No. 9-883-
989-1[]) (page 1-3 to 1-14E) for the use of BLX-104/204.
Operation and Display:
1. BLX-104
Procedure:
1. Select 
23.976Hz/1080p.
2.  Play “4.Motion picture”.
3.  Check whether player can play back or not.
4.  Check each outputs.
 Video:
 Composite/S 
Video/component/HDMI.
 Audio:
 Speaker 
out.
*  When 1080/24p monitor is nothing, 1080i (59.94Hz or 50Hz) 
can use instead of 1080/24p.
 
However this is temporary correspondence.
*  When the output of HDMI is 1080p, the signal of Composite/S 
Video/Component are not output.
 
It is necessary to lower the output of HDMI to 1080i or less.
2. BLX-204
Procedure:
1.  Select 1080i (59.94Hz or 50Hz).
2.  Play “4.Motion picture”.
3.  Check whether player can play back or not.
 
(Check the picture and sound output)
3. CD (YEDS-18)
Procedure:
Check whether player can play back or not.
(Check the sound output)
4.  HLX-504/505 (NTSC), HLX-506/507 (PAL)
Procedure:
1.  After displayed Main Menu, select “1.Video signal”.
2.  Play “1.Color bar 100%”.
 
(Check the picture and sound output)
3.  Return to Menu.
4.  Play “Demonstration 4:3” or “Demonstration 16:9”.
 
(Check the picture and sound output)
4-1-2.  Playback operation confi rmation
Confi rm operation in each signal/output mode of test disc (BLX-
104/204) according to the content of the repair.
Note: “AV Sync.” doesn’t operate.
Page of 112
Display