Sony SAL50F14Z Service Manual ▷ View online
4-12
SAL50F14Z (Planar 1,4/50 ZA) (Planar T*50mm F1.4 ZA SSM)
4-8. ULTRASONIC MOTOR HEIGHT CHECK/ADJUSTMENT
Equipment
• SSM Height Adjustment Jig
• SSM Height ADJ Harpoon Jig
• SSM Height Adjustment Measurement Jig
• SSM Height Adjustment Jig
• SSM Height ADJ Harpoon Jig
• SSM Height Adjustment Measurement Jig
1. Preparation
Set the lens completely, and remove the SSM Holding Plate and the spring (motor).
Set the lens completely, and remove the SSM Holding Plate and the spring (motor).
SSM Holding Plate
Spring (motor)
Fig.
4-8-1
2. Checking Method
1) Attach the SSM Height Adjustment Jig and SSM Height ADJ Harpoon Jig to above the Plate (Pressure Plate) as shown in Fig. 4-8-2.
1) Attach the SSM Height Adjustment Jig and SSM Height ADJ Harpoon Jig to above the Plate (Pressure Plate) as shown in Fig. 4-8-2.
Note:
Install the SSM Height Adjustment Jig with the Focus Stopper Pin placed in the groove.
2) Place the weights at both sides of the SSM Height Adjustment Jig so that the condition below is satisfied. (Fig. 4-8-2)
SSM Height Adjustment Jig + SSM Height ADJ Harpoon Jig + weight = 1600g
3) Measure height in the upper side of SSM Height Adjustment Jig, make the result 0 point.
Note:
Measuring at the near center of SSM Height Adjustment Jig.
SSM Height Adjustment
Measurement Jig
Measurement Jig
SSM Height Adjustment Jig
Groove
Focus Stopper Pin
SSM Height Adjustment Jig
Place the weights here.
(Place them evenly
at both sides.)
(Place them evenly
at both sides.)
SSM Height ADJ
Harpoon Jig
Harpoon Jig
Fig.
4-8-2
4) Then, install the SSM Height Adjustment Jig to above the Focus Stopper Pins.
Note:
Make sure that the lower rim of the SSM Height Adjustment Jig stays on the Focus Stopper Pin when installed the SSM Height Adjustment Jig.
5) Measure height in the upper side of SSM Height Adjustment Jig.
SSM Height Adjustment
Measurement Jig
Measurement Jig
SSM Height
Adjustment Jig
Adjustment Jig
SSM Height Adjustment Jig
Focus Stopper Pin
Groove
Fig.
4-8-3
4-13
SAL50F14Z (Planar 1,4/50 ZA) (Planar T*50mm F1.4 ZA SSM)
3. Adjustment Method
1) According to the result in 2. Checking Method , calculate the ultrasonic motor height using following formula.
1) According to the result in 2. Checking Method , calculate the ultrasonic motor height using following formula.
Measurement result = A
X = A - (3.2 + Marking value of flexible board (lowermost 3 digits))
• In case the value of X is negative (-), decrease the thickness of the SSM Adjustment Washers by value X.
• In case the value of X is positive (+), increase the thickness of the SSM Adjustment Washers by value X.
• In case the value of X is positive (+), increase the thickness of the SSM Adjustment Washers by value X.
Specification: Value of X - Total thickness of all washers = less than
±
0.05 (mm)
Example: In the case the value of A is 4.35 mm
,
lowermost three digits of board is 088
4.35 - (3.2 + 0.88) = 0.27
Increase the thickness of SSM Adjustment Washer by 0.27 mm equivalent.
200088
20008
8
Plate (Pressure Plate),
SSM Holding Sheet
SSM Holding Sheet
SSM Adjustment
Washer
Washer
Fig.
4-8-4
SSM Adjustment Washer
Part Number
Thickness (mm)
4-462-388-01
0.1
4-462-388-11
0.188
Table 4-8-1
2) Remove the SSM Height Adjustment Jig and SSM Height ADJ Harpoon Jig.
3) Assemble the spring (motor) so that its trough avoids the flexible wire of stator.
4) Install the SSM Holding Plate while matching its cutouts with the Focus Stopper Pins.
3) Assemble the spring (motor) so that its trough avoids the flexible wire of stator.
4) Install the SSM Holding Plate while matching its cutouts with the Focus Stopper Pins.
Note:
Use a bundling product in a set for stator, rotor, sheet (middle) (motor), sheet (lower) (motor), spring (motor).
5) Turn the SSM Holding Plate counterclockwise about 30 degrees.
6) Apply adhesive bond (B-10) to fix the Focus Stopper Pins, SSM Holding Plate, and straight moving barrel.
6) Apply adhesive bond (B-10) to fix the Focus Stopper Pins, SSM Holding Plate, and straight moving barrel.
4-9. INSTALLATION OF LENS ADJUSTMENT PROGRAM
4-9-1. Installing the Lens Adjustment Program (ActuatorCheckerSSM)
Equipment used
• Personal Computer
• Lens Adjustment Program (ACSSM-S-VerX.XX.zip)
• Finished Inspection JIG II (AC 100 - 240 V)
• Personal Computer
• Lens Adjustment Program (ACSSM-S-VerX.XX.zip)
• Finished Inspection JIG II (AC 100 - 240 V)
Note 1:
Personal computer must have the condition that Windows Vista/7 runs normally and USB is connectable.
Note 2:
Acquire the Lens Adjustment Program (ACSSM-S-VerX.XX.zip) from the each HQ.
1. Saving Lens Adjustment Program (ACSSM-S-VerX.XX.zip)
1) Unzip the Lens Adjustment Program (ACSSM-S-VerX.XX.zip)
2) Save ACSSM-S-VerX.XX.exe in an arbitrary folder.
1) Unzip the Lens Adjustment Program (ACSSM-S-VerX.XX.zip)
2) Save ACSSM-S-VerX.XX.exe in an arbitrary folder.
Note:
The version of ACSSM-S-VerX.XX.exe might be updated.
4-9-2. Connection of Finished Inspection JIGⅡ and Startup of Lens Adjustment Program (ActuatorCheck-
erSSM)
Note 1:
Confirm that 4-9-1. Installing the Lens Adjustment Program (ActuatorCheckerSSM) has been completed before this procedure is executed.
Note 2:
In case of performing Finished inspection, be sure to perform in the condition that the lens is laid down (do not perform in the lens standing con-
dition).
Equipment
• Personal Computer
• Finished Inspection JIG II (AC 100 - 240 V)
• Personal Computer
• Finished Inspection JIG II (AC 100 - 240 V)
Note:
The cables and so on are not supplied as accessories.
• AC Cable (Sold on the Market)
• RS232C Cable (D-Sub 9 Pins (Male with Securing Screws), D-Sub 9 Pins (Female with Securing Screws)) Straight Type (Sold on the
• RS232C Cable (D-Sub 9 Pins (Male with Securing Screws), D-Sub 9 Pins (Female with Securing Screws)) Straight Type (Sold on the
Market)
• USB to Serial Cable (D-Sub 9 Pins (Male)) (Sold on the Market)
• M-BOX-JIG (J-6082-722-A) (Or the Jig supplied with Finished Inspection JIG (J-6082-645-A))
• Lens Adjustment Program (ACSSM-S-VerX.XX.zip)
• M-BOX-JIG (J-6082-722-A) (Or the Jig supplied with Finished Inspection JIG (J-6082-645-A))
• Lens Adjustment Program (ACSSM-S-VerX.XX.zip)
1. Connection
Connect equipment and checking lens as shown in Fig. 4-9-1.
Note:
Note:
ActuatorCheckerSSM cannot start up without the connection to the finished inspection JIG II.
• Final
Finished Inspection JIG II
AC Cable
D-sub 9 Pins: Male
D-sub 9 Pins: Female
RS232C Cable
USB to Serial Cable
Lens
Fig.
4-9-1
4-14
SAL50F14Z (Planar 1,4/50 ZA) (Planar T*50mm F1.4 ZA SSM)
2. Startup of Lens Adjustment Program (ActuatorCheckerSSM)
1) Turn on the personal computer and the finished inspection JIG II.
2) Start up ACSSM-S-VerX.XX.exe from an arbitrary folder.
1) Turn on the personal computer and the finished inspection JIG II.
2) Start up ACSSM-S-VerX.XX.exe from an arbitrary folder.
Note:
• At the first time using, the followings appear on the screen (Fig. 4-9-2).
• At the first time using, the followings appear on the screen (Fig. 4-9-2).
It is required to ask HQ about the password for the Com/User Characteristic Number and the manufacturer/type name of the personal
computer.
Ex. Com/User Characteristic Number : iYdDZfq9q
computer.
Ex. Com/User Characteristic Number : iYdDZfq9q
Personal Computer :
SONY PCV-RZ33P
• It is no need to input password to the computer once registered.
(The screen requires password does not appear.)
• If the personal computer or the finished inspection JIG II is changed, the password and the Com/User Characteristic Number are
changed.Therefore on the startup, the password input is required again
3) Input the password and click [OK [Ent]], the following appears on the screen (Fig. 4-9-3).
Fig. 4-9-2
Fig. 4-9-3
4-9-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSSM)
1. Start
up ACSSM-S-VerX.XX.exe .
Fig.
4-9-4
2. When the Japanese window appears, click the [Set up] button, change the language to English.
Note:
Depending on the initial startup or setting made at the previous startup, the window differs.
3. Set the following contents in the SETUP window.
MODEL
Model to be adjustment in this time
Language English
State Final
Table
4-9-1
4. Confirm that all of the items are set, and click [Save].
Fig.
4-9-5
5. Click the [Finish] to close the SETUP window.
4-9-4. About Inspection Procedure of Lens Adjustment Program (ActuatorCheckerSSM)
The inspection method has the method of executing the method of inspecting the corresponding model as everything continues and the in-
spection of each item one by one.
Click [START] from the start up window when you inspect the corresponding model as everything continues.
Click the inspection of each item from the start up window, when you inspect one by one.
spection of each item one by one.
Click [START] from the start up window when you inspect the corresponding model as everything continues.
Click the inspection of each item from the start up window, when you inspect one by one.
4-10. FINISHED ADJUSTMENT/INSPECTION (ActuatorCheckerSSM)
4-10-1. Preparation
1) Attach the checking lens to the equipment. (Refer to 4-9-2. Connection of Finished Inspection JIG II and Startup of Lens Adjustment
Program (ActuatorCheckerSSM) ).
2) Start up the lens adjustment program (ACSSM-S-VerX.XX.exe).
3) Click [Setup] and perform the initial setting. (Refer to 4-9-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSSM) ).
3) Click [Setup] and perform the initial setting. (Refer to 4-9-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSSM) ).
Note:
When the Multi Serial window opens, take the following actions.
Process No.: You need not enter process number.
Serial No.:
When the mount block assy is replaced, enter a serial number.
Fig.
4-10-1
4-15
SAL50F14Z (Planar 1,4/50 ZA) (Planar T*50mm F1.4 ZA SSM)
4-10-2. Finished Adjustment/Inspection Item
Perform finished adjustment/inspection item as following procedures.
1. Adjustment/Inspection Method
1) Click [Start[Ent]] on the main screen.
2) SSM frequency input screen is displayed.
1) Click [Start[Ent]] on the main screen.
2) SSM frequency input screen is displayed.
Make sure that the number (upper three digits) written in the flexible wire of the ultrasonic motor (stator) is displayed.
Example: In case the number written in the flexible wire is 217 .
217088
Fig.
4-10-2
3) The respectively adjustment items are automatically executed. When it is normally finished, OK is displayed.
Fig.
4-10-3
2. Adjustment/Inspection item
1) Focus Pattern (Motor)
2) Adjust Driving Frequency & Gain
3) Focus Drive
1) Focus Pattern (Motor)
2) Adjust Driving Frequency & Gain
3) Focus Drive
Note:
When you click the [Start[Ent]], above items are automatically executed, but following items are not executed automatically.
4) MR WavesCheck (Manual)
5) AF/MF Switch
6) Save MR Wave
7) Write
5) AF/MF Switch
6) Save MR Wave
7) Write
⊿
SB
8) Focus Hold Button
9) LVDD1 Consumption Current
10) Focus Aging
11)
9) LVDD1 Consumption Current
10) Focus Aging
11)
⊿
SB is Initialized
12) Check Sounds
13) Search Focus-Adj
13) Search Focus-Adj
Fig.
4-10-4