4-13
SAL18135 (3.5-5.6/18-135 SAM) (DT18-135mm F3.5-5.6 SAM)
4.  Confirm that all of the items are set.
 
 Fig. 
4-7-5
5.  Click the [OK] to close the SETUP window.
4-7-4. About Inspection Procedure of Lens Adjustment Program (ActuatorCheckerSAM)
The inspection method has the method of executing the method of inspecting the corresponding model as everything continues and the 
inspection of each item one by one.
Click [START] from the start up window when you inspect the corresponding model as everything continues.
Click the inspection of each item from the start up window, when you inspect one by one. 
4-8. FINISHED ADJUSTMENT/INSPECTION
Equipment (Only the specific equipment is listed.)
•  Adhesive Bond (B-10)
4-8-1. Preparation
1.  Connect the inspecting lens to the equipment. (Refer to  4-7-2. Connection of Finished Inspection JIG II and Startup of Lens Adjust-
ment Program (ActuatorCheckerSAM) .)
2.  Start up the lens adjustment program (ACSAM-S-VerX.XX.exe).
3.  Click [Setup] and perform the initial setting. (Refer to  4-7-3. Initial Setting of Lens Adjustment Program (ActuatorCheckerSAM) .)
4-8-2. Completion  Adjustment/Inspection  Item
1. Adjustment/Inspection Method
1) Click 
[Start[Ent]].
2)  Follow the instruction on the menu.
2. Adjustment/Inspection Item
1)  Check AF/MF Switch
2)  Check LVDD1 Consumption Current
3)  Adjust Focus Potentio
4) Zoom 
Pattern
5) Adjust PI
6)  Focus Load FB
7)  Check Focus Potentio
8)  Focus Motor Curent
9) Stopping 
Accuracy
10) Write 
SB
Fig. 4-8-1
Note: 
 The following item is not adjusted automatically in the case of Adjustment/Inspection by clicking [Start[Ent]].
11) Search Zoom Adj
4-8-3. Zoom Pattern Inspection
1. Preparation
1)  Disassemble or assemble the lens to be inspected to set it in the state of Fig. 4-8-2.
Note:
  Disassembling the lens is not required during checking.
Focus Rubber Ring (8948)
MF Ring Tape
 Fig. 
4-8-2
2. Checking/Adjustment Method
1)  Set the zoom to the TELE end. At this time, confirm that the brush and the LF-145 flexible board pattern are in the state of Fig4-8-3.
2)  Unscrew the screw securing the zoom brush to adjust the brush position.
Note:
  Adjust the brush position so that the notch A of the LF-145 flexible board pattern matches the contact point B of the brush. (The second pattern 
from the top of the brush contacting patterns)
Cut portion A
(LF-145 FLEXIBLE PWB)
Apply the bond (B-10)
Zoom Brush
Contact portion B
 Fig. 
4-8-3
3)  Click [Inspect zoom pattern] of ACSAM-S.
4)  If the zoom brush is on the TELE adjustment end, the following pop-up window appears.
 Fig. 
4-8-4
5)  Set the zoom to the TELE or WIDE end again and check that the TELE adjustment end is not deviated.
6)  After the adjustment has been completed, apply the bond (B-10) to the screw head. (Refer to Fig.4-8-3.)
4-14
SAL18135 (3.5-5.6/18-135 SAM) (DT18-135mm F3.5-5.6 SAM)
4-8-4. Focusing Error Amount Adjustment (Write SB)
1) Click 
[Write 
SB].
 [Select 
SB] window is displayed.
 
At this time, the current 
SB is highlighted.
2) Write the 
SB based on the error amount that was confirmed by the  4-6. Focusing Error Amount Check .
 Example)
 
When changing the focus to the front (Front focus):   Select the left side of the button (current 
SB) that is highlighted and press the 
[Enter] key.
 
When changing the focus to the rear (Rear focus): 
 Select the right side of the button (current 
SB) that is highlighted and press the 
[Enter] key.
 
 (1) 
 (9)
 
To the front focus  To the rear focus
 Fig. 
4-8-5
3) Performs the 4-6. Focusing Error Amount Check , and check that the error amount is smaller than the reference value. 
 
If the error amount is larger than the reference value, perform [Write 
SB] again, and repeat steps 1) to 3) until the error amount 
becomes less than reference value.
1-1
SAL18135 (3.5-5.6/18-135 SAM) (DT18-135mm F3.5-5.6 SAM)
1. SERVICE NOTE
1-1. 
各種薬品の取り扱いについて
現在使用されている薬品の中には揮発性の高い薬品もあります。
それらを不用意に取り扱い蒸発させてしまうと,環境や健康へ影響を与えたり,資源の無駄使いになります。
各種薬品は,
下記の点に注意して取り扱ってください。
• 
保管場所を定め,高温になったり直射日光の当たらない場所に密閉して保管してください。
• 
小分け
(
ハンドラップ等
)
する数は必要最小限に留め,容器による自然蒸発を防いでください。
• 
作業に使用しない時は,必ずキャップ等をして自然蒸発を防いでください。
• 
薬品を使用する回数を極力少なくし,使用する場合は使用する量だけ容器より出して受け皿に残さないようにしてください。
1-2. 
外装部品の取り扱いについて
本機に使用されている外装部品は,
下記の点に注意して取り扱ってください。
• 
清掃には薬品を使用せず,清掃紙や清掃布を使用してください。
やむを得ず汚れがひどくて薬品を使用する場合は,シンナー,ケトン,エーテルは使用しないでください。
• 
各部品の取り付けには指定されたねじを使用し,部品に対して垂直に取り付けてください。
また,ねじを締め付ける時は,無理な力を加えないでください。
1-3. 
無鉛半田について
本機には無鉛半田が使用されています。
無鉛半田を使用している基板には,無鉛(
Lead Free
)を意味するレッドフリーマークがプリントされています。
注意
:
 
基板サイズによっては,無鉛半田を使用していてもレッドフリーマークがプリントされていないものがあります)
レッドフリーマーク
無鉛半田は,
下記の点に注意して使用してください。
• 
半田こてのこて先温度は約
350
℃に設定してください。
温度調節が無理な場合は,高温短時間で作業を行ってください。
注意:
  
半田こてを長く当てすぎると,基板のパターン(銅箔)がはがれてしまうことがありますので,注意してください。また,従来の半田よりも粘性が強い
ため,
IC
端子などが半田ブリッジしないように注意してください。
• 
半田こてのこて先は,必ず無鉛半田用と有鉛半田用に分けて管理してください。
無鉛半田と有鉛半田が混在すると剥離現象が発生してしまいます。
1-4. SAFETY CHECK-OUT
サービス,点検時には次のことにご注意ください。
1. 
注意事項をお守りください。
サービスのとき特に注意を要する個所については,キャビネット,シャーシ,部品などにラベルや捺印で注意事項を表示しています。これら
の注意書き及び取扱説明書等の注意事項を必ずお守りください。
2. 
指定部品のご使用を
セットの部品は難燃性や耐電圧など安全上の特性を持ったものとなっています。
従って交換部品は,使用されていたものと同じ特性の部品を使用してください。
特に回路図,部品表に0印で指定されている安全上重要な部品は必ず指定のものをご使用ください。
3. 
部品の取付けや配線の引きまわしはもとどおりに
安全上,チューブやテープなどの絶縁材料を使用したり,プリント基板から浮かして取付けた部品があります。
また内部配線は引きまわしやクランパによって発熱部品や高圧部品に接近しないよう配慮されていますので,これらは必ずもとどおりにし
てください。
4. 
サービス後は安全点検を
サービスのために取外したネジ,部品,配線がもとどおりになっているか,またサービスした個所の周辺を劣化させてしまったところがない
かなどを点検し,安全性が確保されていることを確認してください。
5. 
チップ部品交換時の注意
• 
取り外した部品は再使用しないでください。
• 
タンタルコンデンサのマイナス側は熱に弱いため交換時は注意してください。
6. 
フレキシブルプリント基板の取扱いについて
• 
半田こてのこて先温度は約
350
℃に設定してください。
• 
同一パターンに何度もコテ先を当てないでください。
(3
回以内
)
• 
パターンに力が加わらないよう注意してください。
注意
電池の交換は,正しく行わないと破裂する恐れがあります。
電池を交換する場合には必ず同じ型名の電池又は同等品と
交換してください。
使用済み電池は,取扱指示に従って処分してください。
1-2
SAL18135 (3.5-5.6/18-135 SAM) (DT18-135mm F3.5-5.6 SAM)
1-5. 
サービス専用光学ブロック交換時の注意
サービス専用光学ブロックを交換した際には
,
レンズを完成検査治具Ⅱに接続し
,
以下の方法で専用フラグ解除を行なってください。
1. 
レンズ調整プログラム
(ACSAM-S-Ver.X.XX.exe)
を起動する。
2. 
設定をクリックする。
Fig.1-5-1
3. 
下記の画面が表示されるので
,
以下の内容に設定する。
• Model
SAL18135
• Process
Service
• State
FW Unlock
4. OK
をクリックする。
Fig.1-5-2
5. 
下記の画面が表示されるので,
[FW
ロック:解除
をクリックする。
Fig.1-5-3
6. 
正常にフラグが解除された場合は〔
OK
〕表示が出る。
Fig.1-5-4
注意:
 
専用フラグ解除せずに
,
レンズをカメラに装着してもレンズを認識しません。