Sony DSC-S85 (serv.man2) Service Manual ▷ View online
– 17 –
13. Color Reproduction Check
Mode
CAMERA
Subject
Color bar chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Measurement Point
Video terminal of A/V OUT jack
(75
(75
Ω
terminated)
Measuring Instrument
Vectorscope
Specified Value
All color luminance points
should settle within each color
reproduction frame.
should settle within each color
reproduction frame.
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
If not, turn the power of the unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
camera system adjustments”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
00
Press PAUSE button.
11
6
10
01
12
E
52
Note down the data.
13
E
52
09
Press PAUSE button.
14
6
01
0F
Press PAUSE button.
15
6
12
80
16
Wait for 1 second.
17
6
12
00
18
Wait for 2 seconds.
19
Check the each color
luminance point is in each
color reproduction frame.
luminance point is in each
color reproduction frame.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
10
00
3
6
2C
00
4
6
92
00
5
6
93
00
6
E
52
Set the data noted down at
step 12, and press PAUSE
button.
step 12, and press PAUSE
button.
7
Release the data setting
performed at step 2 . (Refer
to page 5-14)
performed at step 2 . (Refer
to page 5-14)
8
0
01
00
Fig. 5-1-17
R-Y
B-Y
R
B
G
M
G
Y
E
C
Y
Burst position
Ver. 1.1 2001. 08
– 18 –
14. Auto White Balance Check
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Measurement Point
Displayed data of Video terminal
of Page: 1
of Page: 1
A/V OUT jack
(Note 3)
(75
Ω
terminated)
Measuring Instrument
Adjusting remote Vectorscope
commander
Specified Value
R ratio:
Fig. 5-1-18
3E00 to 4200
(A) and (B)
B ratio:
3E00 to 4200
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Note 3
: The right 4 digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
Order Page Address Data
Procedure
1
Check that the lens is not
covered with either filter.
covered with either filter.
2
0
01
01
3
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
camera system adjustments”.
(Refer to page 5-14)
4
6
2C
01
5
6
90
00
6
6
91
00
7
6
92
YL
(Note 2)
8
6
93
YH
(Note 2)
9
6
01
79
Press PAUSE button.
10
6
07
Check the data changes to “01”.
11
6
01
00
Press PAUSE button.
INDOOR data check (without ND filter)
12
E
52
Note down the data.
13
E
52
0E
Press PAUSE button.
14
6
01
0F
Press PAUSE button.
15
0
03
04
16
1
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
(Note 3) satisfied the R ratio
specified value.
17
0
03
05
18
1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
(Note 3) satisfied the B ratio
specified value.
INDOOR luminance point check
19
Check that the center of the
white luminance point within
the circle shown
Fig. 5-1-18 (A).
white luminance point within
the circle shown
Fig. 5-1-18 (A).
OUTDOOR luminance check
20
Place the C14 filter on the
lens.
lens.
21
E
4B
Note down the data.
22
E
4B
20
Press PAUSE button.
23
6
01
3F
Press PAUSE button.
24
Check that the center of the
white luminance point settles
in the circle shown
Fig. 5-1-18 (B).
white luminance point settles
in the circle shown
Fig. 5-1-18 (B).
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
6
2C
00
4
6
92
00
5
6
93
00
6
E
4B
Set the data noted down at
step 21, and press PAUSE
button.
step 21, and press PAUSE
button.
7
E
52
Set the data noted down at
step 12, and press PAUSE
button.
step 12, and press PAUSE
button.
8
Release the data setting
performed at step 3 .
(Refer to page 5-14)
performed at step 3 .
(Refer to page 5-14)
9
0
01
00
10
Remove the C14 filter on the
lens.
lens.
R-Y
B-Y
4 mm
4 mm
Fig. 5-1-18 (A)
Fig. 5-1-18 (B)
R-Y
B-Y
1.5 mm
1 mm
6 mm
6 mm
Ver. 1.1 2001. 08
– 19 –
15. CCD White Defect Compensation
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 6,
address: 55
address: 55
Measuring Instrument
Adjusting remote commander
Adjustment Page
7
Adjustment Address
88 to A3
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
camera system adjustments”.
(Refer to page 5-14)
3
F
DE
Note down the data.
4
F
DE
1E
Press PAUSE button.
5
F
E3
Note down the data.
6
F
E3
0E
Press PAUSE button.
7
6
01
8B
Press PAUSE button. (Note 2)
8
6
02
Check the data changes to “01”.
9
6
55
Check the data.
00 to 7F: Normal
80 to FF: Defective
00 to 7F: Normal
80 to FF: Defective
10
6
01
00
Press PAUSE button.
11
F
DE
0F
Press PAUSE button.
12
F
E3
60
Press PAUSE button.
13
6
01
87
Press PAUSE button.
14
6
02
Check the data changes to “01”.
15
6
55
Check the data changes to “00”.
Note 2:
The adjustment data will be automatically input to
page: 7, address: 88 to A3.
page: 7, address: 88 to A3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
F
E3
Set the data noted down at
step 5, and press PAUSE
button.
step 5, and press PAUSE
button.
3
F
DE
Set the data noted down at
step 3, and press PAUSE
button.
step 3, and press PAUSE
button.
4
Release the data setting
performed at step 2 . (Refer
to page 5-14)
performed at step 2 . (Refer
to page 5-14)
5
0
01
00
Ver. 1.1 2001. 08
– 20 –
16. CCD Black Defect Compensation
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame)
(Color reproduction adjustment
frame)
Measurement Point
Displayed data of page: 6,
address: 55
address: 55
Measuring Instrument
Adjusting remote commander
Adjustment Page
7
Adjustment Address
60 to 87
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Note 2:
Check that there are no dust, no dirt and reflection of the
clear chart.
clear chart.
Note 3:
Any subject other than the clear chart should be in the
screen.
screen.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
camera system adjustments”.
(Refer to page 5-14)
3
F
DF
Note down the data.
4
F
DF
4C
Press PAUSE button.
5
6
2C
01
6
6
90
00
7
6
91
03
8
6
92
00
9
6
93
00
10
6
01
79
Press PAUSE button.
11
6
30
01
12
6
07
Check the data changes to “01”.
13
6
01
8D
Press PAUSE button. (Note 4)
14
6
02
Check the data changes to “01”.
15
6
55
Check the data.
00 to 0A: Normal
0B to FF: Defective
00 to 0A: Normal
0B to FF: Defective
16
6
01
00
Press PAUSE button.
17
F
DF
5A
Press PAUSE button.
18
6
01
89
Press PAUSE button.
19
6
02
Check the data changes to “01”.
20
6
55
Check the data changes to “00”.
Note 4:
The adjustment data will be automatically input to
page: 7, address: 60 to 87.
page: 7, address: 60 to 87.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
30
00
4
6
91
00
5
F
DF
Set the data noted down at
step 3, and press PAUSE
button.
step 3, and press PAUSE
button.
6
Release the data setting
performed at step 2 . (Refer
to page 5-14)
performed at step 2 . (Refer
to page 5-14)
7
0
01
00
Click on the first or last page to see other DSC-S85 (serv.man2) service manuals if exist.