DOWNLOAD Sony DSC-S85 (serv.man2) Service Manual ↓ Size: 253.1 KB | Pages: 24 in PDF or view online for FREE

Model
DSC-S85 (serv.man2)
Pages
24
Size
253.1 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-s85-sm2.pdf
Date

Sony DSC-S85 (serv.man2) Service Manual ▷ View online

– 9 –
3.
Flange Back Check
Mode
CAMERA
Subject
Siemens star chart
(1.0 m from the front of the lens)
(Luminance: 200 to 400 lux)
Measurement Point
Check operation on the LCD
Measuring Instrument
screen
Specified value
Focused at the TELE end and
WIDE end
Checking method:
Order Page Address Data
Procedure
1
Place the Siemens star 1.0 m
from the front of the lens.
To open the IRIS , decrease
the luminous intensity to the
Siemens star up to a point
before noise appear on the
image.
2
0
01
01
3
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
4
Shoot the Siemens star chart
with the zoom TELE end.
At this time, the center of
Siemens star chart should be
in the center of the LCD
screen.
5
Check that the lens is
focused.
6
6
2C
01
7
While observe the LCD
screen, change the zoom to
the WIDE end and check that
the lens is focused.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
2C
00
2
Release the data setting
performed at step 3.
(Refer to page 5-14)
3
0
01
00
– 10 –
How to reset the zoom and focus when they deviated:
Order Page Address Data
Procedure
1
6
2C
01
2
6
90
00
3
6
91
00
4
6
92
YL
(Note 2)
5
6
93
YH
(Note 2)
6
6
01
79
Press PAUSE button.
7
6
07
Check the data changes to “01”.
8
6
01
00
Press PAUSE button.
Note 2:
The data noted down at step 9 of “Setting method”.
Check on the oscilloscope
1. Horizontal period
Fig. 5-1-14
2. Vertical period
Fig. 5-1-15
Check on the TV monitor
Fig. 5-1-16
4.
Picture Frame Setting
Mode
CAMERA
Subject
Color bar chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Measurement Point
Video terminal of A/V OUT jack
(75 
 terminated)
Measuring Instrument
Oscilloscope and TV monitor
Specified Value
A=B, C=D, E=F
Note 1:
Displayed data of the page 1 of adjusting remote com-
mander.
1:XX:XX
YL data
YH data
Switch setting:
1) FOCUS ............................................... AF (AUTO FOCUS)
Setting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
Shoot the color bar chart
with the zoom WIDE end.
4
Enter the output of VIDEO
OUT to the TV monitor, and
move to the position as
shown in Fig. 5-1-16.
5
 Horizontal width of one
color (B, C) and that of black
(A, D) on the color bar chart
should be same. (See Fig. 5-
1-14)
6
 With vertical width of black
(E, F) set in same, the color
bar chart should come to the
center of TV monitor.
(See Fig. 5-1-15)
7
Check that the color bar on
the TV monitor is focused.
8
0
03
22
9
1
Note down the YH and YL
data. (Note 1)
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
Release the data setting
performed at step 2 .
(Refer to page 5-14)
3
0
01
00
A=B
C=D
A
B
C
D
Color bar chart picture frame
TV monitor picture frame
E=F
V
E
F
– 11 –
6.
Mechanical Shutter Adjustment
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
Adjustment Page
F
Adjustment Address
5A, 6C to 7F, D4 to D8
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
00
Press PAUSE button.
11
6
01
AD
Press PAUSE button. (Note 3)
12
6
02
Check the data changes to “01”.
13
6
AB
Check the data changes to “00”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 5A, 6C to 7F and D4 to D8.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
92
00
4
6
93
00
5
Release the data setting
performed at step 2 .
(Refer to page 5-14)
6
0
01
00
5.
F No. Standard Data Input
Compensate the unevenness of the iris meter sensitivity.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at WIDE
end)
Adjustment Page
F
Adjustment Address
29 to 2D
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
00
Press PAUSE button.
11
6
01
BB
Press PAUSE button. (Note 3)
12
6
02
Check the data changes to “01”.
Note 3:
The adjustment data will be automatically input to page:
F, address: 29 to 2D.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
92
00
4
6
93
00
5
Release the data setting
performed at step 2 .
(Refer to page 5-14)
6
0
01
00
– 12 –
7.
Light Level Adjustment
Adjust the standard LV value.
Mode
CAMERA
Subject
Clear chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Measurement Point
Displayed data of page: 1 (Note 3)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
26 to 28
Specified Value
AE level: 0FC0 to 1040
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Note 3:
The right 4 digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
 
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
00
Press PAUSE button.
11
6
01
0D
Press PAUSE button. (Note 4)
12
6
02
Check the data changes to “01”.
13
0
03
06
14
1
Check that the displayed data
(Note 3)
satisfies the AE level
specified value.
Note 4:
The adjustment data will be automatically input to
page: F, address: 26 to 28.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
0
03
00
2
6
01
00
Press PAUSE button.
3
6
2C
00
4
6
92
00
5
6
93
00
6
Release the data setting
performed atstep 2 .
(Refer to page 5-14)
7
0
01
00
8.
Mixed Color Cancel Adjustment
To perform mixed color cancel adjustment based on data of each
color in color bar.
Mode
CAMERA
Subject
Color bar chart
(Color reproduction adjustment
frame with the zoom lens at
WIDE end)
Adjustment Page
F
Adjustment Address
A0 to A3
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of the unit OFF/ON.
Note 2:
Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
2C
01
4
6
90
00
5
6
91
00
6
6
92
YL
(Note 2)
7
6
93
YH
(Note 2)
8
6
01
79
Press PAUSE button.
9
6
07
Check the data changes to “01”.
10
6
01
00
Press PAUSE button.
11
6
01
D7
Press PAUSE button.
12
6
01
D5
Press PAUSE button. (Note 3)
13
6
02
Check the data changes to “01”.
Note 3:
The adjustment data will be automatically input to
page: F, address: A0 to A3.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
2C
00
3
6
92
00
4
6
93
00
5
Release the data setting
performed at step 2 . (Refer
to page 5-14)
6
0
01
00
Ver. 1.1  2001. 08
Page of 24
Display