Sony DSC-S85 (serv.man2) Service Manual ▷ View online

– 5 –
Address
Initial value
Remark
8B
00
8C
00
8D
00
8E
00
8F
00
90
00
91
00
92
00
93
00
Flange back adj.
94
00
95
00
96
00
97
00
98
00
99
00
9A
00
9B
00
9C
Fixed data-1 (Initialized data)
9D
16
Smear compensation adj.
9E
1C
9F
Fixed data-1 (Initialized data)
A0
00
A1
00
A2
00
Mixed color cancel adj.
A3
00
A4 to A8
Fixed data-1 (Initialized data)
A9
2C
Auto white balance adj.
AA
06
AB to D3
Fixed data-1 (Initialized data)
D4
80
D5
9E
D6
94
Mechanical shutter adj.
D7
94
D8
94
D9 to FF
Fixed data-1 (Initialized data)
Address
Initial value
Remark
49 to 4C
Fixed data-1 (Initialized data)
4D
28
Strobe white balance adj.
4E
6E
4F to 58
Fixed data-1 (Initialized data)
59
00
Auto white balance standard data input
5A
14
Mechanical shutter adj.
5B
Fixed data-1 (Initialized data)
5C
63
5D
83
Color reproduction adj.
5E
03
5F
E9
60 to 63
Fixed data-1 (Initialized data)
64
10
Strobe white balance adj.
65 to 68
Fixed data-1 (Initialized data)
69
02
6A
79
Strobe white balance adj.
6B
F8
6C
10
6D
05
6E
09
6F
B5
70
07
71
C4
72
07
73
48
74
06
75
CB
Mechanical shutter adj.
76
01
77
01
78
01
79
01
7A
01
7B
2C
7C
3A
7D
2E
7E
40
7F
40
80
00
Auto white balance adj.
81 to 86
Fixed data-1 (Initialized data)
87
FF
88
00
Flange back adj.
89
00
8A
00
Ver. 1.1  2001. 08
– 6 –
1-4.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied.
Note:
For “CAMERA SYSTEM ADJUSTMENTS”, perform in
order of item numbers.
Data setting during camera system adjustments
Perform the following data setting before the camera system ad-
justments.
Menu setting:
1) VIDEO OUT of SET UP menu................ NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don't
set the menu setting to “PAL”)
Data setting method:
Order Page Address Data
Procedure
1
0
01
01
2
D
10
80
Press PAUSE button.
3
2
10
Check the bit values of bit3,
bit4 and bit5 are “1”.
(Note 1, 2)
4
D
11
40
Press PAUSE button.
5
D
10
81
Press PAUSE button.
5
6
C1
Check the data changes to
“02”.
6
4
06
01
7
6
6C
01
8
Wait for 1 second.
9
B
75
00
Press PAUSE button.
Note 1
: For the bit values, refer to “5-2. SERVICE MODE”,
“2-3. 2. Bit value discrimination”.
Note 2:
In case of wrong data, select page: 2, address: 0A and set
data: 02.
Set the adjusting remote commander to normal LANC,
and the power will be turned off and on automatically.
Wait for more than 0.167 second after the power on, and
set the adjusting remote commander to the service LANC.
Then, retry from the step 1.
Note 3:
Repeat the “Data setting method”, if the power was turned
off and on during the “CAMERA SYSTEM ADJUST-
MENTS”.
After completing the camera system adjustments,
release the data setting:
Order Page Address Data
Procedure
1
4
06
00
2
6
6C
00
3
B
75
10
Press PAUSE button.
4
D
11
00
Press PAUSE button.
5
D
10
00
Press PAUSE button.
6
0
01
00
Ver. 1.1  2001. 08
– 7 –
1.
Flange Back Adjustment (Using the minipattern box)
The flange back of inner focus lens is adjusted automatically. If
shifted, the auto focus is disordered.
Mode
CAMERA
Subject
Siemens star chart with ND filter
for minipattern box (Note 1)
Measurement Point
Check operation on the LCD
Measuring Instrument
screen
Adjustment Page
F
Adjustment Address
14 to 25, 87 to 9B
Note 1:
Dark Siemens star chart.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
1) The minipattern box is installed as shown in the following fig-
ure.
Note 3:
 The attachment lenses are not used.
Note 4:
 Take care not to hit the mini-pattern box when
extending the lens.
2) Install the minipattern box so that the distance between it and
the front of lens of camera is less than 3 cm.
3) Make the height of minipattern box and the camera equal.
4) Check the output voltage of the regulated power supply is the
specified voltage ± 0.01 Vdc.
5) Check that the center of Siemens star chart meets the center of
shot image screen with the zoom lens at TELE end and WIDE
end respectively.
6) Check that the data on page: F, address: 14 to 25 and 87 to 9B
are initial value (See table below).
Specified voltage: The specified voltage varies according to the
minipattern box, so adjustment the power sup-
ply output voltage to the specified voltage writ-
ten on the sheet which is supplied with the mini-
pattern box.
Minipattern box
Below 3 cm
Camera
Camera 
table
Red (+)
Black (–)
Yellow (SENS +)
White (SENS –)
Black (GND)
Need not connected
Regulated power supply
Output voltage : Specified voltage 
±
 0.01 Vdc
Output current : more than 3.5 A
Fig. 5-1-13
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
01
13
Press PAUSE button.
4
6
01
27
Press PAUSE button. (Note 5)
5
6
02
Check the data changes to “01”.
6
F
87
Check the data changes to “00”.
Note 5:
The adjustment data will be automatically input to page:
F, address: 14 to 25 and 87 to 9B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 2. (Refer to
page 5-14)
3
0
01
00
4
Perform“Flange Back Check”.
Address
Data
Address
Data
Address
Data
14
33
21
20
8F
00
15
48
22
BA
90
00
16
DA
23
46
91
00
17
DF
24
0A
92
00
18
13
25
00
93
00
19
C0
87
FF
94
00
1A
00
88
00
95
00
1B
00
89
00
96
00
1C
00
8A
00
97
00
1D
00
8B
00
98
00
1E
00
8C
00
99
00
1F
00
8D
00
9A
00
20
20
8E
00
9B
00
– 8 –
2.
Flange Back Adjustment
(Using the flange back adjustment chart)
The flange back of inner focus lens is adjusted automatically. If
shifted, the auto focus is disordered.
Mode
CAMERA
Subject
Flange back adjustment chart
(2.0 m from the front of the lens)
(Luminance: 300 to 400 lux)
Measurement Point
Check operation on the LCD
Measuring Instrument
screen
Adjustment Page
F
Adjustment Address
14 to 25, 87 to 9B
Note 1:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Preparations before adjustments:
1) Place the Flange back adjustment chart 2.0 m from the front
of the lens.
2) Check that the center of Flange back adjustment chart meets
the center of shot image screen with the zoom lens at TELE
end and WIDE end respectively.
3) Check that the data on page: F, address: 14 to 25 and 87 to 9B
are initial value (See table below).
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
Perform “Data setting during
camera system adjustments”.
(Refer to page 5-14)
3
6
01
13
Press PAUSE button.
4
6
01
15
Press PAUSE button. (Note 2)
5
6
02
Check the data changes to “01”.
6
F
87
Check the data changes to “00”.
Note 2:
The adjustment data will be automatically input to
page: F, address: 14 to 25 and 87 to 9B.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
Release the data setting
performed at step 2.
(Refer to page 5-14)
3
0
01
00
4
Perform“Flange Back Check”.
Address
Data
Address
Data
Address
Data
14
33
21
20
8F
00
15
48
22
BA
90
00
16
DA
23
46
91
00
17
DF
24
0A
92
00
18
13
25
00
93
00
19
C0
87
FF
94
00
1A
00
88
00
95
00
1B
00
89
00
96
00
1C
00
8A
00
97
00
1D
00
8B
00
98
00
1E
00
8C
00
99
00
1F
00
8D
00
9A
00
20
20
8E
00
9B
00
Page of 24
Display