DOWNLOAD Sony DSC-S30 / DSC-S50 (serv.man2) Service Manual ↓ Size: 6.6 MB | Pages: 96 in PDF or view online for FREE

Model
DSC-S30 DSC-S50 (serv.man2)
Pages
96
Size
6.6 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-s30-dsc-s50-sm2.pdf
Date

Sony DSC-S30 / DSC-S50 (serv.man2) Service Manual ▷ View online

5-24
16. CCD Black Defect Compensation
Mode
STILL
Subject
Clear chart
(25 cm from the front of lens)
Measurement Point
Displayed data of page: 6, address: 55
Measuring Instrument Adjusting remote commander
Adjustment Page
7
Adjustment Address
60 to 87
Note 1:
Check that there are no dust, no dirt and reflection of the
clear chart.
Note 2:
Any subject other than the clear chart should be in the
screen.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
4)
Perform “ Data setting during camera system adjustment”.
(Refer to page 5-13)
5)
Select page: F, address: DF, after noting down the data, set
data: 4C, and press the PAUSE button.
6)
Select page: 6, address: 2C, and set data: 01.
7)
Select page: 6, address: 90, and set data: 00.
8)
Select page: 6, address: 91, and set data: 03.
9)
Select page: 6, address: 92, and set data: 00.
10) Select page: 6, address: 93, and set data: 00.
11) Select page: 6, address: 6C, and set data: 01.
12) Select page: 6, address: 01, set data: 79, and press the PAUSE
button.
13) Select page: 6, address: 30, and set data: 01.
14) Wait 4 seconds.
15) Select page: 6, address: 01, set data: 8D, and press the PAUSE
button. (The CCD black defect compensation is performed
and the compensation data is stored in page: 7, address: 60
to 87)
16) Select page: 6, address: 02, and check that the data is “01”.
17) Select page: 6, address: 55, and check the data.
00 to 0A: Normal
0B to FF: Defective
18) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
19) Select page: F, address: DF, set data: 5A, and press the PAUSE
button.
20) Select page: 6, address: 01, set data: 89, and press the PAUSE
button.
21) Select page: 6, address: 02, and check that the data is “01”.
22) Select page: 6, address: 55, and check the data .
00: Normal
01 to FF: Defective
Processing after Completing Adjustments:
1)
Select page: F, address: DF, set data noted down at step 5)
and press the PAUSE button of the adjusting remote
commander.
2)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
3)
Select page: 6, address: 2C, and set data: 00.
4)
Select page: 6, address: 30, and set data: 00.
5)
Select page: 6, address: 6C, and set data: 00.
6)
Select page: 6, address: 91, and set data: 00.
7)
Select page: 5, address: F1, and set data: 00.
8)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
9)
Release the data setting performed at step 4).
(Refer to page 5-13)
10)
Select page: 0, address: 01, and set data: 00.
17. CCD White Defect Compensation
Mode
STILL
Subject
Clear chart
(25 cm from the front of lens)
Measurement Point
Displayed data of page: 6, address: 55
Measuring Instrument Adjusting remote commander
Adjustment Page
7
Adjustment Address
88 to A3
Note 1:
Check that there are no dust, no dirt and reflection of the
clear chart.
Note 2:
Any subject other than the clear chart should be in the
screen.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
4)
Perform “ Data setting during camera system adjustment”.
(Refer to page 5-13)
5)
Select page: F, address: DE, after noting down the data, set
data: 1E, and press the PAUSE button.
6)
Select page: F, address: E3, after noting down the data, set
data: 08, and press the PAUSE button.
7)
Select page: 6, address: 01, set data: 8B, and press the PAUSE
button. (The CCD white defect compensation is performed
and the compensation data is stored in page: 7, address: 88
to A3)
8)
Select page: 6, address: 02, and check that the data is “01”.
9)
Select page: 6, address: 55, and check the data.
00 to 7F: Normal
80 to FF: Defective
10) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
11) Select page: F, address: DE,  set data: 0F, and press the PAUSE
button.
12) Select page: F, address: E3, set data: A0, and press the PAUSE
button.
13) Select page: 6, address: 01, set data: 87, and press the PAUSE
button.
14) Select page: 6, address: 02, and check that the data is “01”.
15) Select page: 6, address: 55, and check the data.
00: Normal
01 to FF: Defective
Processing after Completing Adjustments:
1)
Select page: F, address: DE, set data noted down at step 5)
and press the PAUSE button of the adjusting remote com-
mander.
2)
Select page: F, address: E3, set data noted down at step 6)
and press the PAUSE button.
3)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
4)
Select page: 5, address: F1, and set data: 00.
5)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
6)
Release the data setting performed at step 4).
(Refer to page 5-13)
7)
Select page: 0, address: 01, and set data: 00.
5-25
Fig. 5-1-19
[Adjusting connector]
Most of the measuring points for adjusting the LCD system are
concentrated in CN709 of the SY-58 board.
Connect the Measuring Instruments via the CPC-9 jig (J-6082-
393-C).
The following table shows the Pin No. and signal name of CN709.
Pin No.
Signal Name
Pin No.
Signal Name
1
N. C.
10
UNREG
2
N. C.
11
LANC IN
3
N. C.
12
LANC OUT
4
REG GND
13
N. C.
5
XCPC_IN
14
RF7
6
N. C.
15
TXD
7
HSY
16
RXD
8
PANEL COM
17
RESET
9
VG
18
VDD
Table 5-1-7
• ATTACHMENT OF CPC-9 JIG
SY-58 board
(CN709)
CPC lid 
(Note 3)
Open the battery lid assembly
BT holder 
assembly
Note 1: Don’t use the 12 pin flexible board of 
CPC-9 jig. It causes damage to the unit.
Note 2: The old CPC-9 jig (Parts code: J-6082-393-B) 
cannot be used, because it cannot operate 
the adjustment remote commander.
Note 3: In removing the CPC lid, start from
the upper side.
CPC-9 jig (J-6082-393-C) 
(18P flexible board) 
(Note 1, 2)
CPC lid
1
18
1
18
1-5.
LCD SYSTEM ADJUSTMENTS
Before perform the LCD system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied.
Note 1:
The back light (fluorescent tube) is driven with high volt-
age AC power. Therefore, do not touch the back light
directly, otherwise you will feel an electric shock.
Note 2:
Taken an extreme care not to destroy the liquid crystal
display module by static electricity when replacing it.
Note 3:
Set the LCD BRIGHT to the center.
5-26
1. LCD Initial Data Input
Mode
PLAY
Signal
Arbitrary
Adjustment Page
D
Adjustment Address
1C, 1C, D0 to D8, DD to DF
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, and enter the data given in the following table.
Note:
Press the PAUSE button of the adjusting remote commander
each time the data are set, as the data are written to non-
volatile memory (EEPROM).
Processing after Completing Adjustments:
1) Select page: 0, address: 01, and set data: 00.
2. VCO Adjustment (PD-127 Board)
Set the VCO free-run frequency.  If deviated, the LCD screen will
be blurred.
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 7 of CN709 (HSY) on SY-
58 board
Measuring Instrument
Frequency counter
Adjustment Page
D
Specified Value
D7 (NTSC)
DD (PAL)
Specified Value
f = 15734 ± 30 Hz (NTSC)
f = 15745 ± 30 Hz (PAL)
Menu setting:
1) VIDEO OUT of SET UP menu................ NTSC (NTSC mode)
(This adjustment must be performed in NTSC mode, so don't
set the menu setting to “PAL”)
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 5, address: F0, and set data: 01.
3) Select page: D, address: D7, change the data and set the fre-
quency (f) to the NTSC specified value.
4) Press the PAUSE button of the adjusting remote commander.
5) Select page: D, address: DD, and change the data and set the
frequency (f) to the PAL specified value.
6) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments:
1) Select page: 5, address: F0, and set data: 00.
2) Select page: 0, address: 01, and set data: 00.
Address
Data
Remark
1C
02
Fixed value
1D
2C
D0
BC
Bright Adjustment
D1
80
Color Adjustment
D2
B9
White Balance Adjustment
D3
B7
D4
BE
Contrast Adjustment
D5
C8
D Range Adjustment
D6
7C
V-COM Level Adjustment
D7
80
VCO Adjutment (NTSC)
D8
74
V-COM Adjustment
DD
88
VCO Adjutment (PAL)
DE
13
Fixed value
DF
11
5-27
A
2H 
Pedestal 
Pedestal
A: Pedestal level difference between 1H period and
previous 1H period.
Fig. 5-1-20
4. Bright Adjustment (PD-127 Board)
Set the level of the VIDEO signal for driving the LCD to the speci-
fied value.
If deviated, the LCD screen image will be blackish or saturated
(whitish).
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN709 (VG) on SY-58
board
External trigger: Pin 8 of CN709
(PANEL COM) on SY-58 board
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D0
Specified Value
A = 1.85 ± 0.08 Vp-p
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 5, address: F1, and set data: 03.
3) Select page: 2, address: 10, and set data: 01.
4) Select page: D, address: D0, change the data and set the volt-
age (A) between the pedestal and GAMMA 1 limiter  level to
the specified value.
5) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments:
1) Select page: 5, address: F1, and set data: 00.
2) Select page: 2, address: 10, and set data: 00.
3) Select page: 0, address: 01, and set data: 00.
Fig. 5-1-21
A
2H 
GAMMA1 limiter level
Pedestal
3. D Range Adjustment (PD-127 Board)
Set the D range of the LCD driver to the specified value.
If deviated, the LCD screen will became blackish or saturated
(whitish)
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN709 (VG) on SY-58
board
External trigger: Pin 8 of CN709
(PANEL COM) on SY-58 board
Measuring Instrument
Oscilloscope
Adjustment Page
D
Adjustment Address
D5
Specified Value
A = 3.62 ± 0.05 Vp-p
Adjusting method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 5, address: F1, and set data: 03.
3) Select page: D, address: D5, change the data and set the volt-
age (A) between the reversed waveform pedestal and non-re-
versed waveform pedestal to the specified value.
4) Press the PAUSE button of the adjusting remote commander.
Processing after Completing Adjustments:
1) Select page: 5, address: F1, and set data: 00.
2) Select page: 0, address: 01, and set data: 00.
Page of 96
Display

Click on the first or last page to see other DSC-S30 / DSC-S50 (serv.man2) service manuals if exist.