DOWNLOAD Sony DSC-S30 / DSC-S50 (serv.man2) Service Manual ↓ Size: 6.6 MB | Pages: 96 in PDF or view online for FREE

Model
DSC-S30 DSC-S50 (serv.man2)
Pages
96
Size
6.6 MB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / LEVEL 2
File
dsc-s30-dsc-s50-sm2.pdf
Date

Sony DSC-S30 / DSC-S50 (serv.man2) Service Manual ▷ View online

5-8
3. D Page table
Note 1:
 Fixed data-1: Initialized data.
(Refer to “1. Initializing the D Page Data”)
Note 2:
 Fixed data-2: Modified data.
(Refer to “2. Modified of D Page Data”)
Address
Initial value
Remark
S30
S50
00 to 0F
10 to 1B
Fixed data-1 (Initialized data)
1C
Fixed data-2
1D
1E to 5F
Fixed data-1 (Initialized data)
60
Fixed data-2
61
62
63
64 to 6F
Fixed data-1 (Initialized data)
70
Fixed data-2
71
72 to 84
Fixed data-1 (Initialized data)
85
Fixed data-2
86 to 8F
Fixed data-1 (Initialized data)
90
80
80
Battery down adj.
91
88
88
92
AD
AD
93
C2
C2
94
CD
CD
95 to 97
Fixed data-1 (Initialized data)
98
Fixed data-2
99
9A
9B
9C
9D
9E
9C
A0
A1
A2 to A4
Fixed data-1 (Initialized data)
A5
Fixed data-2
A6
A7,A8
Fixed data-1 (Initialized data)
A9
Fixed data-2
AA to CF
Fixed data-1 (Initialized data)
D0
BC
BC
Bright adj. (LCD)
D1
80
80
Color adj. (LCD)
D2
B9
B9
White balance adj. (LCD)
D3
B7
B7
D4
BE
BE
Contrast adj. (LCD)
D5
C8
C8
D Range adj. (LCD)
D6
7C
7C
V-COM Level adj. (LCD)
D7
80
80
VCO adj. (NTSC) (LCD)
D8
74
74
V-COM adj. (LCD)
D9 to DC
Fixed data-1 (Initialized data)
DD
88
88
VCO adj. (PAL) (LCD)
DE
Fixed data-2
DF
E0 to EF
Fixed data-1 (Initialized data)
1-2.
INITIALIZATION OF B, D, E, F, 7 PAGE DATA
1-2-1. INITIALIZATION OF D PAGE DATA
1. Initializing the D Page Data
Note:
If the D page data has been initialized, the following
adjustments need to be performed again.
1) Modification of D page data
2) LCD system adjustments
3) Battery end adjustments
Adjusting page
D
Adjusting Address
10 to EF
Initializing Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 2, address: 03, and set data: 03 (S30) or data: 02
(S50).
3) Select page: 2, address: 00, and set data: 2D.
4) Select page: 2, address: 01, set data: 2D, and press the PAUSE
button of the adjustment remote commander.
5) Select page: 2, address: 02, and check that the data changes to
“01”.
6) Perform “Modification of D Page Data”.
2. Modification of D Page Data
If the D page data has been initialized, change the data of the “Fixed
data-2” address shown in the following table by manual input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note :
If copy the data built in the different model, the
camcorder may not operate.
3) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of D Page data
1)
Select page: 2, address: 00, and set data: 29.
2)
Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.
5-9
1-2-2. Initializing the B, E, F, 7 Page Data
1. Initializing the B, E, F, 7 Page Data
Note:
If the B, E, F Page data has been initialized, “Modification
of B, E, F, 7 Page Data” and following adjustments need
to be performed again.
1) Modification of B, E, F, 7 page data
2) Video system adjustments
3) Camera system adjustments
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
7
Adjusting Address
00 to FF
Initializing Method:
1) Select page: 0, address: 01, and set data: 01.
2) Select page: 6, address: 00, and set data: 2D.
3) Select page: 6, address: 01, set data: 2D, and press the PAUSE
button of the adjustment remote commander.
4) Select page: 6, address: 02, and check that the data changes to
“01”.
5) Perform “Modification of B, E, F, 7 Page Data”.
2. Modification of B, E, F, 7 Page Data
If the B, E, F, 7 Page data has been initialized, change the data of
the “Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the
camcorder may not operate.
3) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of B, E, F, 7 Page data
1) Select page: 2, address: 00, and set data: 29.
2) Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.
3. B Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the B, E, F, 7 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modified of B, E, F, 7 Page Data”)
Address
Initial value
Remark
S30
S50
00
Fixed data-2
01 to FF
Fixed data-1 (Initialized data)
4. E Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to “1. Initializing the B, E, F, 7 Page Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to “2. Modified of B, E, F, 7 Page Data”)
Address
Initial value
Remark
S30
S50
00 to F5
Fixed data-1 (Initialized data)
F6
Fixed data-2
F7 to FF
Fixed data-1 (Initialized data)
5-10
5. F Page table
Note 1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B, E, F, 7 Page Data”)
Note 2:
Fixed data-2: Modified data. (Refer to “2. Modified of B, E, F, 7 Page Data”)
Address
Initial value
Remark
S30
S50
00 to 0F
10 to13
Fixed data-1 (Initialized data)
14
12
12
Flange back adj.
15
A8
A8
16
18
18
17
C5
C5
18
12
12
19
C9
C9
1A
00
00
1B
00
00
1C
00
00
1D
00
00
1E
41
41
1F
00
00
20
20
20
21
20
20
22
20
20
23
44
44
24
0A
0A
25
00
00
26
6B
7D
Light level adj.
27
Fixed data-1 (Initialized data)
28
7B
8D
Light level adj.
29
4F
52
F No. standard data input
2A
49
4B
2B
42
45
2C
40
42
2D
Fixed data-1 (Initialized data)
2E
7C
7E
Hall adj
2F
9A
9B
30 to 33
Fixed data-1 (Initialized data)
34
15
15
Hall adj
35
7D
7D
36 to 39
Fixed data-1 (Initialized data)
3A
2F
2F
Auto white balance standard data input
3B
37
37
3C
40
40
3D
D0
D0
3E
Fixed data-1 (Initialized data)
3F
B5
B5
Auto white balance adj.
40
43
43
41
03
03
Color reproduction adj.
42
E9
E9
43
63
63
44
83
83
45
D5
D5
46
FE
FE
47
73
73
48
45
45
49 to 4C
Fixed data-1 (Initialized data)
4D
27
27
Strobe white balance adj.
4E
77
77
4F to 58
Fixed data-1 (Initialized data)
59
00
00
Auto white balance standard data input
5A
14
14
Mechanical shutter adj.
Address
Initial value
Remark
S30
S50
5B
Fixed data-1 (Initialized data)
5C
63
63
Color reproduction adj.
5D
83
83
5E
03
03
5F
E9
E9
60 to 63
Fixed data-1 (Initialized data)
64
10
10
Strobe white balance adj.
65
61
61
Video sync level adj.
66
61
61
Video burst level adj.
67, 68
Fixed data-1 (Initialized data)
69
00
01
Strobe white balance adj.
6A
AD
38
6B
00
00
6C
0B
0B
Mechanical shutter adj.
6D
C2
C2
6E
09
09
6F
42
42
70
06
06
71
C2
C2
72
05
05
73
C2
C2
74
04
04
75
C2
C2
76
33
33
77
33
33
78
33
33
79
33
33
7A
33
33
7B
33
33
7C
33
33
7D
33
33
7E
33
33
7F
33
33
80
00
00
Auto white balance adj.
81 to 9F
Fixed data-1 (Initialized data)
A0
00
00
Mixed color cancel adj.
A1
00
00
A2
00
00
A3
00
00
A4 to FF
Fixed data-1 (Initialized data)
5-11
6. 7 Page table
Note 1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B, E, F, 7 Page Data”)
Note 2:
Fixed data-2: Modified data. (Refer to “2. Modified of B, E, F, 7 Page Data”)
Address
Initial value
Remark
S30
S50
00 to 5F
Fixed data-1 (Initialized data)
60
0F
0F
CCD black defect compensation
61
FF
FF
62
0F
0F
63
FF
FF
64
0F
0F
65
FF
FF
66
0F
0F
67
FF
FF
68
0F
0F
69
FF
FF
6A
0F
0F
6B
FF
FF
6C
0F
0F
6D
FF
FF
6E
0F
0F
6F
FF
FF
70
0F
0F
71
FF
FF
72
0F
0F
73
FF
FF
74
0F
0F
75
FF
FF
76
0F
0F
77
FF
FF
78
0F
0F
79
FF
FF
7A
0F
0F
7B
FF
FF
7C
0F
0F
7D
FF
FF
7E
0F
0F
7F
FF
FF
80
0F
0F
81
FF
FF
82
0F
0F
83
FF
FF
84
0F
0F
85
FF
FF
86
0F
0F
87
FF
FF
88
0F
0F
CCD white defect compensation
89
FF
FF
8A
0F
0F
8B
FF
FF
8C
0F
0F
8D
FF
FF
8E
0F
0F
8F
FF
FF
90
0F
0F
91
FF
FF
92
0F
0F
Address
Initial value
Remark
S30
S50
93
FF
FF
CCD white defect compensation
94
0F
0F
95
FF
FF
96
0F
0F
97
FF
FF
98
0F
0F
99
FF
FF
9A
0F
0F
9B
FF
FF
9C
0F
0F
9D
FF
FF
9E
0F
0F
9F
FF
FF
A0
0F
0F
A1
FF
FF
A2
0F
0F
A3
FF
FF
A4 to FF
Fixed data-1 (Initialized data)
Page of 96
Display