Sony DSC-S30 / DSC-S50 (serv.man2) Service Manual ▷ View online
5-20
11. Color Reproduction Adjustment
Adjust the color separation matrix coefficient so that proper color
reproduction is produced.
reproduction is produced.
Mode
STILL
Subject
Color bar chart
(Color reproduction adjustment frame)
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
41 to 48, 5C to 5F
Note 1:
Perform “Auto White Balance Standard Data Input”
before this adjustment.
before this adjustment.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
button of the adjusting remote commander.
4)
Perform “ Data setting during camera system adjustment”.
(Refer to page 5-13)
(Refer to page 5-13)
5)
Select page: 6, address: 01, set data: AB, and press the PAUSE
button.
button.
6)
Select page: 6, address: 12, set data: 80, and press the PAUSE
button.
button.
7)
Wait for 1 second.
8)
Select page: 6, address: 12, set data: 00, and press the PAUSE
button.
button.
9)
Wait for 2 seconds.
10) Select page: 6, address: 01, set data: A9, and press the PAUSE
button. (The color reproduction adjustment is performed and
the adjustment data is stored in page: F, address: 41 to 48,
5C to 5F)
the adjustment data is stored in page: F, address: 41 to 48,
5C to 5F)
11) Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1)
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
button of the adjusting remote commander.
2)
Select page: 5, address: F1, and set data: 00.
3)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
button.
4)
Release the data setting performed at step 4).
(Refer to page 5-13)
(Refer to page 5-13)
5)
Select page: 0, address: 01, and set data: 00.
6)
Perform “Color Reproduction Check”.
5-21
M
G
Y
E
C
Y
R-Y
B-Y
R
B
G
Burst position
M
G
Y
E
C
Y
R-Y
B-Y
R
B
G
Burst position
For NTSC mode
For PAL mode
Fig. 5-1-16
Fig. 5-1-17
12. Color Reproduction Check
Mode
STILL
Subject
Color bar chart
(Color reproduction adjustment frame)
(Color reproduction adjustment frame)
Measurement Point
Video terminal of A/V OUT jack
(75
(75
Ω
terminated)
Measuring Instrument Vectorscope
Specified Value
All color luminance points shouldsettle
within each color reproduction frame.
within each color reproduction frame.
Menu setting:
1)
1)
VIDEO OUT of SET UP menu
................................
NTSC (NTSC mode)
................................
PAL (PAL mode)
Checking method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
button of the adjusting remote commander.
4)
Perform “ Data setting during camera system adjustment”.
(Refer to page 5-13)
(Refer to page 5-13)
5)
Check that the picture frame is set to the specified position.
(Refer to “6. picture Frame Setting” )
(Refer to “6. picture Frame Setting” )
6)
Select page: 6, address: 10, and set data: 01.
7)
Select page: E, address: 52, after noting down the data, set
data: 0A, and press the PAUSE button.
data: 0A, and press the PAUSE button.
8)
Select page: 6, address: 01, set data: 0F, and press the PAUSE
button.
button.
9)
Select page: 6, address: 12, set data: 80, and press the PAUSE
button.
button.
10) Wait for 1 second.
11) Select page: 6, address: 12, set data: 00, and press the PAUSE
11) Select page: 6, address: 12, set data: 00, and press the PAUSE
button.
12) Wait for 2 seconds.
13) Check the each color luminance point in each color repro-
13) Check the each color luminance point in each color repro-
duction frame.
Processing after Completing Adjustments:
1)
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
button of the adjusting remote commander.
2)
Select page: 6, address: 10, and set data: 00.
3)
Select page: E, address: 52, set data noted down at step 7)
and press the PAUSE button.
and press the PAUSE button.
4)
Select page: 5, address: F1, and set data: 00.
5)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
button.
6)
Release the data setting performed at step 4).
(Refer to page 5-13)
(Refer to page 5-13)
7)
Select page: 0, address: 01, and set data: 00.
5-22
Fig. 5-1-18 (A)
R-Y
B-Y
4mm
4mm
R-Y
B-Y
2.5mm
1mm
6mm
6mm
13. White Balance Check
Mode
STILL
Subject
Clear chart
(Color reproduction adjustment frame)
(Color reproduction adjustment frame)
Measurement Point
Displayed data of
Video terminal of
Page: 1 (Note 2)
A/V OUT jack
(75
(75
Ω
terminated)
Measuring Instrument Adjustment remote
Vectorscope
Commander
Specified Value
R ratio: 3E00 to 4200 Fig. 5-1-18
B ratio: 3E00 to 4200 (A) and (B)
B ratio: 3E00 to 4200 (A) and (B)
Note 1:
Refer to “6. Picture Frame Setting” for XH, XL, YH and
YL.
YL.
Note 2:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
adjusting remote commander.
1:XX:XX
Displayed data
Checking method:
1)
1)
Check that the lens is not covered with either filter.
2)
Select page: 0, address: 01, and set data: 01.
3)
Select page: 5, address: F1, and set data: FF.
4)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
button of the adjusting remote commander.
5)
Perform “ Data setting during camera system adjustment”.
(Refer to page 5-13)
(Refer to page 5-13)
6)
Select page: 6, address: 90, and set data: XL. (Note 1)
7)
Select page: 6, address: 91, and set data: XH. (Note 1)
8)
Select page: 6, address: 92, and set data: YL. (Note 1)
9)
Select page: 6, address: 93, and set data: YH. (Note 1)
10) Select page: 6, address: 6C, and set data: 01.
11) Select page: 6, address: 01, set data: 79, press the PAUSE
11) Select page: 6, address: 01, set data: 79, press the PAUSE
button, and wait for 1 second.
12) Select page: 6, address: 2C, and set data: 01.
•
•
INDOOR data check
13) Select page: E, address: 52, after noting down the data, set
data: 0E, and press the PAUSE button.
14) Select page: 6, address: 01, set data: 0F, and press the PAUSE
button.
15) Select page: 0, address: 03, and set data: 04.
16) Select page: 1, and check that the displayed data (Note 2)
16) Select page: 1, and check that the displayed data (Note 2)
satisfies the R ratio specified value.
17) Select page: 0, address: 03, and set data: 05.
18) Select page: 1, and check that the displayed data (Note 2)
18) Select page: 1, and check that the displayed data (Note 2)
satisfies the B ratio specified value.
•
INDOOR luminance point check
19) Select page: 6, address: 1C, and set data: 00.
20) Select page: 0, address: 03, and set data: 00.
21) Check that the center of the white luminance point is within
20) Select page: 0, address: 03, and set data: 00.
21) Check that the center of the white luminance point is within
the circle shown Fig. 5-1-18 (A).
•
OUTDOOR luminance point check
22) Place the C14 filter on the lens.
23) Select page: E, address: 4B, after noting down the data, set
23) Select page: E, address: 4B, after noting down the data, set
data: 20, and press the PAUSE button.
24) Select page: 6, address: 01, set data: 3F, and press the PAUSE
button.
25) Check that the center of the white luminance point settles in
the circle shown Fig. 5-1-18 (B).
Processing after Completing Adjustments:
1)
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
button of the adjusting remote commander.
2)
Select page: 6, adderss: 6C, and set data: 00.
3)
Select page: E, address: 52, set data noted down at step 13)
and press the PAUSE button.
and press the PAUSE button.
4)
Select page: E, address: 4B, set data noted down at step 23)
and press the PAUSE button.
and press the PAUSE button.
5)
Select page: 5, address: F1, and set data: 00.
6)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
button.
7)
Release the data setting performed at step 5).
(Refer to page 5-13)
(Refer to page 5-13)
8)
Select page: 0, address: 01, and set data: 00.
R-Y
B-Y
4mm
8mm
8mm
Fig. 5-1-18 (B)
DSC-S30
DSC-S50
5-23
15. Strobe Light Level and White balance Check
Check the light level regulation and the white balance when the
strobe light flashed.
strobe light flashed.
Mode
STILL
Subject
Flash adjustment box (Note 3)
(1.0 m from the front of lens)
Measurement Point
Displayed data of page: 1
Measuring Instrument Adjusting remote commander
Specified value
Y level data: 60 to 94
R-Y level data: FA to FF or 00 to 06
(Note 4)
B-Y level data: FA to FF or 00 to 06
(Note 4)
R-Y level data: FA to FF or 00 to 06
(Note 4)
B-Y level data: FA to FF or 00 to 06
(Note 4)
Note 1:
Perform this checking successively after performing
“HALL Adjustment”, “Flange Back Adjustment”, “ Light
Level Adjustment”, “Strobe White Balance Adjustment”
and “Auto White Balance Standerd Data Input”. (Do not
turn the power of unit OFF)
“HALL Adjustment”, “Flange Back Adjustment”, “ Light
Level Adjustment”, “Strobe White Balance Adjustment”
and “Auto White Balance Standerd Data Input”. (Do not
turn the power of unit OFF)
Note 2:
Perform this adjustment in the Flash adjustment box.
Note 3:
Refer to “4. Preparing the Fiash adjustment box”.
(See page 5-7)
(See page 5-7)
Note 4:
The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:XX:XX
1:XX:XX
B-Y level data
R-Y level data
Note 5:
Displayed data of page: F, address: 64 of the adjusting
remote commander.
remote commander.
F:XX:64
Y level data
Note 6:
Check that the data of page: 6, address: 02 is “00”.
Checking method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 6, address: 01, set data: 79, and press the PAUSE
button of the adjusting remote commander.
button of the adjusting remote commander.
3)
Select page: 6, address: 01, set data: 67, and press the PAUSE
button.
button.
4)
Check the flashing of strobe light.
5)
Select page: F, address: 64, and check that the data satisfies
the Y level data specified value. (Note 5)
the Y level data specified value. (Note 5)
6)
Select page: 0, address: 03, and set data: 02.
7)
Select page: 1, and check the R-Y, B-Y level data (Note 4)
satisfies the specified value.
satisfies the specified value.
Processing after Completing Adjustments:
1)
1)
Select page: 0, address: 03, and set data: 00.
2)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
button of the adjusting remote commander.
3)
Select page: 6, address: 2C, and set data: 00.
4)
Select page: 6, address: 6C, and set data: 00.
5)
Select page: 6, address: 93, and set data: 00.
6)
Select page: 7, address: 03, set data: 00, and press the PAUSE
button.
button.
7)
Select page: 5, address: F1, and set data: 00.
8)
Select page: D, address: 63, set data: 00, and press the PAUSE
button.
button.
9)
Release thedata setting performed at step 4) of “Strobe White
Balance Adjustment”. (Refer to page 5-13)
Balance Adjustment”. (Refer to page 5-13)
10) Select page: 0, address: 01, and set data: 00.
14. Strobe White Balance Adjustment
Adjust the white balance when the strobe light flashed.
Mode
STILL
Subject
Flash adjustment box (Note 3)
(1.0 m from the front of lens)
Adjustment Page
F
Adjustment Address
4D, 4E, 64, 69, 6A, 6B
Note 1:
Perform “HALL Adjustment”, “Flange Back Adjust-
ment”, “Light Level Adjustment”, “Auto White Balance
Adjustment” and “Auto White Balance Standerd Data In-
put” before this adjustment.
ment”, “Light Level Adjustment”, “Auto White Balance
Adjustment” and “Auto White Balance Standerd Data In-
put” before this adjustment.
Note 2:
Perform this adjustment in the Flash adjustment box.
Note 3:
Refer to “4. Preparing the Flash adjustment box”.
(See page 5-7)
(See page 5-7)
Note 4:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
If not, turn the power of unit OFF/ON.
Switch setting:
1)
1)
FLASH ......................
ON
Adjusting method:
1)
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 5, address: F1, and set data: FF.
3)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
button of the adjusting remote commander.
4)
Perform “ Data setting during camera system adjustment”.
(Refer to page 5-13)
(Refer to page 5-13)
5)
Select page: 7, address: 03, and set data: 08.
6)
Select page: 6, address: 90, and set data: 00.
7)
Select page: 6, address: 91, and set data: 00.
8)
Select page: 6, address: 92, and set data: 00.
9)
Select page: 6, address: 93, and set data: 80.
10) Select page: 6, address: 6C, and set data: 01.
11) Select page: 6, address: 2C, and set data: 01.
12) Select page: 6, address: 01, set data: 79, and press the PAUSE
11) Select page: 6, address: 2C, and set data: 01.
12) Select page: 6, address: 01, set data: 79, and press the PAUSE
button.
13) Select page: 6, address: 01, set data: 67, and press the PAUSE
button.
14) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
15) Select page: 6, address: 01, set data: 79, and press the PAUSE
button.
16) Select page: 6, address: 01, set data: 67, and press the PAUSE
button.
17) Select page: 6, address: 01, set data: 00, and press the PAUSE
button.
18) Select page: 6, address: 01, set data: 79, and press the PAUSE
button.
19) Select page: 6, address: 01, set data: B9, and press the PAUSE
button. (The strobe white balance adjustment is performed
and the adjustment data is stored in page: F, address: 4D, 4E,
64, 69, 6A and 6B)
and the adjustment data is stored in page: F, address: 4D, 4E,
64, 69, 6A and 6B)
20) Select page: 6, address: 02, and check that the data is “01”.
Processing after Completing Adjustments:
1)
1)
Select page: 6, address: 01, set data: 00, and press the PAUSE
button of the adjusting remote commander.
button of the adjusting remote commander.
2)
Perform “Strobe Light Level and White Balance Check” suc-
cessively. (Do not turn the power of unit OFF)
cessively. (Do not turn the power of unit OFF)
Click on the first or last page to see other DSC-S30 / DSC-S50 (serv.man2) service manuals if exist.