DOWNLOAD Sony DSC-P8 (serv.man4) Service Manual ↓ Size: 426.24 KB | Pages: 37 in PDF or view online for FREE

Model
DSC-P8 (serv.man4)
Pages
37
Size
426.24 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-p8-sm4.pdf
Date

Sony DSC-P8 (serv.man4) Service Manual ▷ View online

DSC-P8
6-7
4.
Preparing the Flash Adjustment Box
A dark room is required to provide an accurate flash adjustment.
If it is not available, prepare the flash adjustment box as given
below;
1) Provide woody board A, B and C of 15 mm thickness.
2) Apply black mat paint to one side of woody board A and B.
3) Attach background paper (J-2501-130-A) to woody board C.
4) Assemble so that the black sides and the background paper
side of woody board A, B and C are internal. (Fig. 6-1-8)
Fig. 6-1-7
Fig. 6-1-8
woody board A (2)
400 mm
woody board B (2)
370 mm
woody board C (1)
700 mm
513 mm
513 mm
700 mm
700 mm
730 mm
woody board A
woody board B
woody board B
woody board C
woody board A
DSC-P8
6-8
COVER
COVER
1-2.
INITIALIZATION  OF  0E,  2F,  4F,  6F  PAGE
DATA
1-2-1.
Initialization of 0E, 2F, 4F, 6F Page Data
1.
Initializing of 0E, 2F, 4F, 6F Page Data
Note 1:
Initialize the data every page of 0E, 2F, 4F, and 6F.
Note 2:
If the 4F page data has been initialized, the following
adjustments need to be performed again.
1) Video system adjustment
2) LCD system adjustments
Note 3:
If the 6F page data has been initialized, the following
adjustments need to be performed again.
1) Camera system adjustments
Adjusting Page
0E
Adjusting Address
00 to FF
Adjusting Page
2F
Adjusting Address
00 to 7F
Adjusting Page
4F
Adjusting Address
00 to FF
Adjusting Page
6F
Adjusting Address
00 to FF
Initializing Method:
1) Click 
[Page Edit]
 on the SEUS screen to display the SEUS
PAGE EDIT screen.
2) Click 
[Page]
, and then enter the page to be initialized.
3) Click 
[Preset Data Read]
 to display the Set ID input screen.
4) For page 0E, enter Set ID = “00” and read the initializing data
on the SEUS PAGE EDIT screen.
5) For page 2F, 4F and 6F, enter Set ID = “08” and read the ini-
tializing data on the SEUS PAGE EDIT screen.
6) On the SEUS PAGE EDIT screen, change the data at “Fixed
data-2” address given in the table on the page to be initialized.
Note:
New data for change are not listed in the table. If the
data are to be changed, read and copy the data from the
same model. Copying the data from different models
may cause an operation failure.
7) Confirm that the data at respective adjustment addresses are
the initial values (adjustment initial values) given in the table.
If different, change to the adjustment initial values.
8) Click 
[Write]
 to write the initializing data to the set.
9) Click 
[Close]
 to close the SEUS PAGE EDIT screen.
Processing after Completing Initializing
Order Page Address
Data
Procedure
1
2F
21
04 
[Write]
2
20
00
29 
[set]
3
20
01
29 
[Write]
(Note)
Note:
At this time, the set is reset and the power is turns off once
and then on again. Accordingly, the message “Receive
Packet Error” is displayed on the SEUS screen, and the
SEUS goes in “disconnect” state, but this is not a trouble.
Click 
[Connect]
 on the SEUS screen to restore the “con-
nected” state.
2.
0E Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to step 4 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to step 6 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Address
Initial value
Remark
00 to FF
Fixed data-1 (Initialized data)
3.
2F Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to step 5 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to step 6 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Address
Initial value
Remark
00 to 20
Fixed data-1 (Initialized data)
21
00
Test mode
22 to 7F
Fixed data-1 (Initialized data)
4.
4F Page table
Note 1:
Fixed data-1: Initialized data.
(Refer to step 5 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to step 6 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Address
Initial value
Remark
00 to 81
Fixed data-1 (Initialized data)
82
90
VCO adj. (NTSC mode)
83
9A
VCO adj. (PAL mode)
84
91
V-COM adj.
85
AF
Bright adj.
86
2D
Black limit adj.
87
Fixed data-1 (Initialized data)
88
8C
White balance adj.
89
6C
8A
42
Contrast adj.
8B to 9F
Fixed data-1 (Initialized data)
A0
80
Video sync level adj.
A1 to A7
Fixed data-1 (Initialized data)
A8
Fixed data-2
A9
Fixed data-2
AA to FF
Fixed data-1 (Initialized data)
DSC-P8
6-9
Address
Initial value
Remark
3A
00
Flange back adj.
3B
00
3C
00
3D
00
3E
FF
3F
Fixed data-1 (Initialized data)
40
00
41
00
42
00
43
00
44
00
45
00
46
00
47
00
48
00
49
00
Flange back adj.
4A
00
4B
00
4C
00
4D
00
4E
00
4F
00
50
00
51
00
52
00
53
00
54 to 5F
Fixed data-1 (Initialized data)
60
00
61
00
62
00
F No. compensation
63
00
64
00
65
30
66
FE
Light value adj.
67
6D
68 to 6A
Fixed data-1 (Initialized data)
6B
FF
F No. compensation
6C
00
Mechanical shutter adj.
6D
00
6E
00
Mixed color calcel adj.
6F
00
70
40
71
90
72
17
73
DF
AWB 3200K standard data input
74
3E
75
A8
76
19
5.
6F Page Table
Note 1:
Fixed data-1: Initialized data.
(Refer to step 5 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Note 2:
Fixed data-2: Modified data.
(Refer to step 6 of “ 1. Initializing of 0E, 2F, 4F, 6F Page
Data”)
Address
Initial value
Remark
00 to 0F
Fixed data-1 (Initialized data)
10
FF
11
FF
12
FF
13
FF
AF Ilumination check.
14
00
15
90
16
FF
 17
FF
18
34
19
F5
1A
87
1B
71
1C
10
1D
C0
1E
00
1F
00
20
00
21
00
22
00
23
00
24
20
25
20
26
26
27
46
28
0A
29
00
Flange back adj.
2A
00
2B
00
2C
00
2D
00
2E
00
2F
00
30
00
31
00
32
00
33
00
34
00
35
00
36
00
37
00
38
00
39
00
DSC-P8
6-10
Address
Initial value
Remark
A7
B0
A8
0D
A9
04
AA
9E
AB
97
Color reproduction adj.
AC
86
AD
AF
AE
F9
AF
F8
B0
00
AWB 3200K standard data input
B1
00
AWB 5800K standard data input
B2
00
AWB 3200K standard data input
B3
00
AWB 5800K standard data input
B4
00
AWB 3200K standard data input
B5
Fixed data-1 (Initialized data)
B6
26
Strobe balance adj.
B7
74
B8
10
B9
37
BA
10
BB
37
BC
00
BD
00
BE
00
BF
00
C0
00
C1
00
C2
00
C3
00
C4
00
C5
00
C6
00
C7
28
Mechanical shutter adj.
C8
1B
C9
00
CA
00
CB
00
CC
80
CD
88
CE
98
CF
90
D0
88
D1
00
D2
00
D3
00
D4
00
D5
00
D6
00
Address
Initial value
Remark
77
36
78
00
79
00
7A
00
7B
00
7C
00
7D
00
7E
00
7F
00
AWB 3200K standard data input
80
00
81
00
82
00
83
00
84
00
85
00
86
00
87
00
88
28
89
9B
8A
24
8B
39
8C
27
8D
1F
8E
25
8F
8A
90
00
91
00
92
00
93
00
94
00
95
00
AWB 5800K standard data input
96
00
97
00
98
00
99
00
9A
00
9B
00
9C
00
9D
00
9E
00
9F
00
A0
2B
A1
00
A2
60
A3
00
A4
FE
A5
F9
Color reproduction adj.
A6
88
Page of 37
Display