DOWNLOAD Sony DSC-P8 (serv.man4) Service Manual ↓ Size: 426.24 KB | Pages: 37 in PDF or view online for FREE

Model
DSC-P8 (serv.man4)
Pages
37
Size
426.24 KB
Type
PDF
Document
Service Manual
Brand
Device
Digital Camera / SECTION 6 ADJUSTMENTS
File
dsc-p8-sm4.pdf
Date

Sony DSC-P8 (serv.man4) Service Manual ▷ View online

DSC-P8
6-19
8.
AWB 5800K Standard Data Input
Adjust the white balance reference at 5800K.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter
Filter C14 for color temperature
correction
Adjustment Page
6F
Adjustment Address
88 to A3, B1, and B3
Specified value
00
Note 1:
Check that the data of page: 60, address: 02 is “00”. If
not, press the RESET switch using a thin and long pin.
Note 2:
Perform this check after “AWB 3200K Standard Data
Input” without a break.
Adjusting method:
Order Page Address
Data
Procedure
1
Place the C14 filter on
the lens.
2
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
3
Perfom “Picture frame
setting”
(Refer to page 6-14)
4
6F
A0
2B 
[Write]
5
6F
A1
00 
[Write]
6
6F
A2
60 
[Write]
7
6F
A3
00 
[Write]
8
6F
B5
FF 
[Write]
9
60
01
A5 
[Write]
(Note 3)
10
60
02
[Read]
Check the data changes
to “01”.
11
6F
B5
[Read]
Check that the data
satisfied the specified
value.
Note 3:
The adjustment data will be automatically input to page:
6F, address: 88 to A3, B1 and B3.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data settig
during camera system
adjustment”
(Refer to page 6-13)
9.
AWB 5800K Check
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Filter
Filter C14 for color temperature
correction
Measurement Point
Data of page: 6F, address: B5
Specified value
00
Note:
Check that the data of page: 60, address: 02 is “00”. If not,
press the RESET switch using a thin and long pin.
Checking method:
Order Page Address
Data
Procedure
1
Place the C14 filter on
the lens.
2
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
3
Perfom “Picture frame
setting”
(Refer to page 6-14)
4
6F
B5
FF 
[Write]
5
60
01
3F 
[Write]
6
60
02
[Read]
Check the data changes
to “01”.
7
6F
B5
[Read]
Check that the data
satisfied the specified
value.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data settig
during camera system
adjustment”
(Refer to page 6-13)
DSC-P8
6-20
10. AWB 3200K Check
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point
Data of page: 6F, address: B5
Specified value
00
Note:
Check that the data of page: 60, address: 02 is “00”. If not,
press the RESET switch using a thin and long pin.
Checking method:
Order Page Address
Data
Procedure
1
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
2
Perfom “Picture frame
setting”
(Refer to page 6-14)
3
6F
B5
FF 
[Write]
4
60
01
0F 
[Write]
5
60
02
 
[Read]
Check the data changes
to “01”.
6
6F
B5
[Read]
Check that the data
satisfied the specified
value. (Note 2)
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
60
01
00 
[Write]
2
Release “Data settig
during camera system
adjustment”
(Refer to page 6-13)
11. CCD Linearity Check
Check that CCD output keep being staraight even ISO sensitivity
is changed.
Mode
CAMERA
Subject
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Specified value 1
97 to 103 (Decimal)
Specified value 2
96 to 104 (Decimal)
Note:
2byte data is upper 1byte data and lower 1byte data.
XX XX
Lower 1byte data
(Page: 10, address: 81 or 83)
Upper 1byte data
(Page: 10, address: 80 or 82)
Checking method:
Order Page Address
Data
Procedure
1
Perfom “Data setting
during camera sysem
adjustment”.
(Refer to page 6-13)
2
Perfom “Picture frame
setting”
(Refer to page 6-14)
3
75
09
04 
[Set]
4
60
1F
80 
[Set]
5
77
F7
40 
[Set]
6
77
F2
00 
[Set]
7
60
12
9F 
[Set]
8
60
14
90 
[Set]
9
60
05
16 
[Set]
10
60
3C
28 
[Set]
11
60
3D
54 
[Set]
12
60
3E
14 
[Set]
13
60
3F
2A 
[Set]
14
Wait for 2 seconds.
15
60
01
F9 
[Write]
16
Wait for 1 second.
17
10
80
[Read]
Read the data
(Upper 1byte).
Note down the data, and
this is named D
02
.
18
10
81
[Read]
Read the data
(Lower 1byte).
Note down the data, and
this is named D
03
.
19
This 2byte data (Note) is
named D
1
.
20
6D
02
D
02
 
[Write]
Write the data noted
down at order No. 17.
21
6D
03
D
03
 
[Write]
Write the data noted
down at order No. 18.
22
6D
0A
D
02
 
[Write]
Write the data noted
down at order No. 17.
23
6D
0B
D
03
 
[Write]
Write the data noted
down at order No. 18.
DSC-P8
6-21
Order Page Address
Data
Procedure
24
10
82
[Read]
Read the data
(Upper 1byte).
Note down the data, and
this is named D
06
.
25
10
83
[Read]
Read the data
(Lower 1byte).
Note down the data, and
this is named D
07
.
26
This 2byte data (Note) is
named D
2
.
27
6D
06
D
06
 
[Write]
Write the data noted
down at order No. 24.
28
6D
07
D
07
 
[Write]
Write the data noted
down at order No. 25.
29
6D
0E
D
06
 
[Write]
Write the data noted
down at order No. 24.
30
6D
0F
D
07
 
[Write]
Write the data noted
down at order No. 25.
31
60
01
00 
[Write]
32
77
72
48 
[Set]
33
Wait for 2 seconds.
34
60
01
F9 
[Write]
35
Wait for 1 second.
36
10
80
[Read]
Read the data
(Upper 1byte).
Note down the data, and
this is named D
00
.
37
10
81
[Read]
Read the data
(Lower 1byte).
Note down the data, and
this is named D
01
.
38
This 2byte data (Note) is
named D
3
.
39
6D
00
D
00
 
[Write]
Write the data noted
down at order No. 36.
40
6D
01
D
01
 
[Write]
Write the data noted
down at order No. 37.
41
10
82
[Read]
Read the data
(Upper 1byte).
Note down the data, and
this is named D
04
.
42
10
83
[Read]
Read the data
(Lower 1byte).
Note down the data, and
this is named D
05
.
43
This 2byte data (Note) is
named D
4
.
44
6D
04
D
04
 
[Write]
Write the data noted
down at order No. 41.
45
6D
05
D
05
 
[Write]
Write the data noted
down at order No. 42.
46
60
01
00 
[Write]
47
77
72
09 
[Set]
48
Wait for 2 seconds.
49
60
01
F9 
[Write]
50
Wait for 1 second.
Order Page Address
Data
Procedure
51
10
80
[Read]
Read the data
(Upper 1byte).
Note down the data, and
this is named D
08
.
52
10
81
[Read]
Read the data
(Lower 1byte).
Note down the data, and
this is named D
09
.
53
This 2byte data (Note) is
named D
5
.
54
6D
08
D
08
 
[Write]
Write the data noted
down at order No. 51.
55
6D
09
D
09
 
[Write]
Write the data noted
down at order No. 52.
56
10
82
[Read]
Read the data
(Upper 1byte).
Note down the data, and
this is named D
0C
.
57
10
83
[Read]
Read the data
(Lower 1byte).
Note down the data, and
this is named D
0D
.
58
This 2byte data (Note) is
named D
6
.
59
6D
0C
D
0C
 
[Write]
Write the data noted
down at order No. 56.
60
6D
0D
D
0D
 
[Write]
Write the data noted
down at order No. 57.
61
60
01
00 
[Write]
62
60
12
00 
[Set]
63
60
14
00 
[Set]
64
60
1F
00 
[Set]
65
60
05
00 
[Set]
66
60
3C
00 
[Set]
67
60
3D
00 
[Set]
68
60
3E
00 
[Set]
69
60
3F
00 
[Set]
70
75
09
[Read]
71
77
F7
[Read]
72
77
F2
[Read]
73
77
72
[Read]
74
Convert D
3
 to decimal
notation, and obtain D
3
’.
75
Convert D
1
 to decimal
notation, and obtain D
1
’.
76
Calculate S
1
 using
following equations.
(Decimal calculation)
S
1
=(D
3
÷D
1
’) 
× 100
77
Check that the S
1
satisfies the specified
value 1.
DSC-P8
6-22
Order Page Address
Data
Procedure
78
Convert S
1
 to
hexadecimal notation.
This Upper 1byte data is
named S
10
.
This Lower 1byte data is
named S
11
.
79
6D
10
S
10
 
[Write]
Write the Upper 1byte
data obtained at order
No. 78.
80
6D
11
S
11
 
[Write]
Write the Lower 1byte
data obtained at order
No. 78.
81
Convert D
4
 to decimal
notation, and obtain D
4
’.
82
Convert D
2
 to decimal
notation, and obtain D
2
’.
83
Calculate S
2
 using
following equations.
(Decimal calculation)
S
2
=(D
4
÷D
2
’) 
× 100
84
Check that the S
2
satisfies the specified
value 1.
85
Convert S
2
 to
hexadecimal notation.
This Upper 1byte data is
named S
12
.
This Lower 1byte data is
named S
13
.
86
6D
12
S
12
 
[Write]
Write the Upper 1byte
data obtained at order
No. 85.
87
6D
13
S
13
 
[Write]
Write the Lower 1byte
data obtained at order
No. 85.
88
Convert D
5
 to decimal
notation, and obtain D
5
’.
89
Convert D
1
 to decimal
notation, and obtain D
1
’.
90
Calculate S
3
 using
following equations.
(Decimal calculation)
S
3
=(D
5
÷D
1
’) 
× 100
91
Check that the S
3
satisfies the specified
value 2.
92
Convert S
3
 to
hexadecimal notation.
This Upper 1byte data is
named S
14
.
This Lower 1byte data is
named S
15
.
93
6D
14
S
14
 
[Write]
Write the Upper 1byte
data obtained at order
No. 92.
94
6D
15
S
15
 
[Write]
Write the Lower 1byte
data obtained at order
No. 92.
Order Page Address
Data
Procedure
95
Convert D
6
 to decimal
notation, and obtain D
6
’.
96
Convert D
2
 to decimal
notation, and obtain D
2
’.
97
Calculate S
4
 using
following equations.
(Decimal calculation)
S
4
=(D
6
÷D
2
’) 
× 100
98
Check that the S
4
satisfies the specified
value 2.
99
Convert S
4
 to
hexadecimal notation.
This Upper 1byte data is
named S
16
.
This Lower 1byte data is
named S
17
.
100
6D
16
S
16
 
[Write]
Write the Upper 1byte
data obtained at order
No. 99.
101
6D
17
S
17
 
[Write]
Write the Lower 1byte
data obtained at order
No. 99.
Processing after Completing Adjustments:
Order Page Address
Data
Procedure
1
Release “Data settig
during camera system
adjustment”
(Refer to page 6-13)
Page of 37
Display